Read High-sensitivity silicon nitride microring resonator opto-fluidic sensor by D.O. Armstrong, S. Ibrahim, S. Naserikarimvand, S. Whelan, O.J. Guy, A.J. Bennett, J.P. Hadden (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-19528.txt.
Introduction
D. O. Armstrong and six colleagues build tiny sensors that can detect chemicals dissolved in a liquid. Their device is a photonic integrated circuit, a small chip that guides light instead of electric current. On the chip sits a microring resonator, a loop that traps light at set wavelengths. When a target substance is present, the light in the loop shifts, and that shift signals a detection.
The team studies how sensitive such a sensor can be. Their rings are made from silicon nitride, a material known for low light loss. The key measure is how much the signal moves when the liquid's refractive index changes by a small amount. High sensitivity means the chip can flag very low concentrations. Such sensors could serve in medical tests and water checks where samples are small.
Catalog record
| CREATOR | D.O. Armstrong, S. Ibrahim, S. Naserikarimvand, S. Whelan, O.J. Guy, A.J. Bennett, J.P. Hadden |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 21 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2601-19528
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
High-sensitivity silicon nitride microring resonator opto-fluidic sensor Preprint: AIP/123-QED D.O. Armstrong, S. Ibrahim, S. Naserikarimvand, S. Whelan, O.J. Guy, A.J. Bennett, J.P. Hadden Abstract Photonic integrated circuit devices can be used as refractometric opto-fluidic sensors to detect the presence of analytes in solution at low concentrations. In this work, we investigate the refractive index sensitivity of silicon nitride microring resonator based photonic integrated circuit fluidic sensors. The performance of a foundry fabricated sensor is measured over the C-band in the presence of liquid samples achieving a mean sensitivity of 579 nanometres per refractive index unit. This demonstration of a scalable, high-sensitivity opto-fluidic sensor, compatible with recognition marker surface functionalisation, opens the way to applications in environmental and bio-sensing. I Introduction In recent years there has been an increase in the demand for medical diagnostic tools which can be used outside of laboratory settings, in clinics, or directly by patients. The increased adoption of self-monitoring apparatus for personal healthcare have accelerated the research and development of low-cost, highly-deployable biochemical sensors, facilitating the lab-on-chip paradigm 8 . One application of miniaturised biochemical sensors is in the field of environmental monitoring. Contaminants in water supplies—from pathogenic microorganisms and viruses to toxic chemicals—pose significant risks to both public health and the environment. Yet, current monitoring approaches remain slow, expensive, and heavily reliant on centralised laboratory facilities, creating a bottleneck in environmental analysis. By leveraging photonic integrated circuits (PICs) with tailored surface chemistries via functionalisation, solutions to this bottleneck can offer highly sensitive, real-time analysis without the need for lengthy sample processing. This enabling technology will not only provide earlier intervention and safer water systems, but also demonstrate the transformative potential of integrated photonic sensors for widespread adoption in environmental, agricultural, and healthcare applications. Sensors based on optical microring resonators (MRRs) are among the leading chip-scale photonic sensors that have been demonstrated. The working principle of these devices is that optical resonances of the MRRs are affected by the interaction of the resonant modes’ evanescent field with the components of a liquid solution in which the MRR is immersed. Surface-functionalisation of the MRR with recognition markers which bind to specific targets within the solution then allows transduction of the target capture to detectable shifts in the optical resonant wavelength. In order to maximise the sensitivity of MRR biosensing devices therefore, the device should be engineered such that the optical resonances are as sensitive as possible to changes in the surrounding refractive index due to the presence of a particular analyte of interest (AOI). MRR sensors have been demonstrated featuring optical resonances with moderate-to-high quality (Q) factors of 10,000100,000\text{\,}\mathrm{,} offering refractive index sensitivities of hundreds of nanometres of resonance shift per refractive index unit (RIU), low detection limits ( 10^{-7}10^{-4}\text{\,}\mathrm{R}\mathrm{I}\mathrm{U} ) and compact footprint of up to hundreds of square microns 7 ; 6 ; 14 . MRRs are also favourable for their ability to be fabricated in dense arrays, allowing for multiplexed analysis. Various different implementations of MRR-based fluidic sensors have been demonstrated in the literature. A summary of recently demonstrated MRR-based fluidic sensors fabricated on SiN and silicon-on-insulator (SOI) platforms can be found in Table 1 . Of particular note is Chen, et al’s demonstration, with a sensitivity of 5752.5\text{\,}\mathrm{n}\mathrm{m}\mathrm{/}\mathrm{R}\mathrm{I}\mathrm{U} , consisting of a feedback-coupled microring resonator device which includes a more complicated MRR geometry. To the author’s knowledge is the highest reported sensitivity in the literature. Table 1: Examples of MRR-based fluidic sensors in the literature. Waveguide type Sensitivity (nm/RIU) Q-factor Mode/ Band Reference SiN Strip 579 23,000 TE/C This work SiN Strip 179.7 24,000 TE/C Bryan, et al. 3 SiN Strip 200 - TM/O Castelló-Pedrero, et al. 4 SOI Slot 433.3 4300 TE/C Liu, et al. 11 SOI Porous Slab 380 10,000 TE/C Rodriguez et al. 13 SOI Strip 5752.5 - TE/C Chen, et al. 5 Figure 1: Experimental setup. (a) Schematic of the experimental setup used to characterise our SiN MRRs. (b) SEM micrograph of a fabricated 40\text{\,}\mathrm{\SIUnitSymbolMicro} radius MRR. (c) Schematic of the SiN MRR immersed in analyte. (d) Schematic cross section of the SiN sample tray showing how analyte solutions are delivered to the sensing microring. (e) Camera image of the SiN photonic chip with etched channel shown. Intuitively, high Q-factor microcavity sensors offer increased precision through sharper resonances, however these devices typically have reduced interaction between the cavity mode and the AOI due to their more confined field. The narrow resonance bandwidth, which requires a strict resonance spectral alignment, is also sensitive to temperature fluctuation and other environmental factors which may cause undesired resonance shifts, thus compromising reliability. Therefore, devices with lower Q-factor but more interaction with the AOI may provide higher refractive index sensitivity. In this work, we investigate the sensitivity of a foundry fabricated silicon nitride (SiN) microring resonator-based photonic integrated circuit fluidic sensor. SiN is a material platform which is especially attractive for PIC sensors due to its wide transparency window ( 300\text{\,}\mathrm{n}\mathrm{m} to beyond 8000\text{\,}\mathrm{n}\mathrm{m} ) low-loss waveguides ( <0.1\text{\,}\mathrm{d}\mathrm{B}\mathrm{/}\mathrm{c}\mathrm{m} ) 9 , comparable to its silicon-on-insulator counterparts and low thermo-optic coefficient ( 2.45\text{\times}{10}^{-5}\text{\,}\mathrm{R}\mathrm{I}\mathrm{U}\mathrm{/}\mathrm{K} ) 1 . It offers wide refractive index tuneability through stoichiometry adjustment allowing great flexibility in optical waveguide design. This means that waveguides and modal characteristics can tuned to the need of the PIC sensor; enabling low-index-contrast device designs for fibre-waveguide mode matching or alternatively high-index-contrast components for low-loss propagation. SiN photonic fabrication is also CMOS compatible, allowing scalable fabrication and integration with integrated electronics 12 . The sensor’s optical response is investigated over the C-band from 1528\text{\,}\mathrm{n}\mathrm{m} to 1568\text{\,}\mathrm{n}\mathrm{m} in the presence of liquid analytes, demonstrating a mean sensitivity of 579 nanometres per refractive index unit. II Microring resonator refractometric sensors Refractometric measurements for a MRR in the presence of a certain AOI involves the tracking of shifts to the resonant modes in wavelength in response to a change in the effective refractive index n_{eff} which they experience within the sensing region. This shift can be measured by scanning a laser across the resonance and measuring its position in wavelength through transmission spectroscopy. The MRR’s resonant modes are related to the microring resonance condition through \lambda_{res}=2\pi n_{eff}R/m (1) where \lambda_{res} is the resonant wavelength, R is the effective radius of the mode in the MRR, and m is the azimuthal mode order 8 . Thus a change in the effective index will cause a detectable change in the resonant wavelengths. We also define the Q-factor, which relates to the average number of round trips the light makes around the ring before it is lost to internal losses, the sensitivity, S , which is determined by the extent of the overlap between the AOI and the evanescent field and the limit of detection (LOD), which refers to the smallest detectable change in the surrounding refractive index. These are expressed as Q=\frac{\lambda_{res}}{\Gamma}, (2) where \Gamma is the full-width half-maximum of the resonance, S=\frac{\Delta\lambda_{res}}{\Delta n_{clad}}, (3) and LOD=\frac{\lambda_{res}}{QS}. (4) III Experimental Results Microring resonator characterisation PIC microring resonator sensor chips were fabricated through the 300\text{\,}\mathrm{n}\mathrm{m} SiN multi-project-wafer service at the CORNERSTONE foundry 10 . Devices are patterned in a 300\text{\,}\mathrm{n}\mathrm{m} epilayer of Si 3 N 4 grown by low-pressure chemical vapour deposition (LPCVD) on a 3\text{\,}\mathrm{\SIUnitSymbolMicro} buried oxide layer of thermal silica