Nanomechanical sensor resolving impulsive forces below its zero-point fluctuations

Martynas Skrabulis 1,2, Martin Colombano Sosa 1,2, Nicola Carlon Zambon 3, Andrei Militaru 4, Massimiliano Rossi 5, Martin Frimmer 1,2, Lukas Novotny 1,2 · 2026

Read Nanomechanical sensor resolving impulsive forces below its zero-point fluctuations by Martynas Skrabulis 1,2, Martin Colombano Sosa 1,2, Nicola Carlon Zambon 3, Andrei Militaru 4, Massimiliano Rossi 5, Martin Frimmer 1,2, Lukas Novotny 1,2 (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-19392.txt.

Introduction

Martynas Skrabulis and five co-authors measure shoves smaller than a sensor's own quantum jitter. A mechanical sensor's sensitivity ends at its inherent quantum fluctuations, or so the standard story goes. The team uses an optically levitated nanoparticle, a bead of glass held by light, as their sensor.

By squeezing the bead's motion in a reversible way, they resolve impulsive forces below its zero point uncertainty. The trick does not break quantum rules; it reshapes where the noise sits. Such sensors could weigh the faintest kicks in physics, from tiny particles to faint fields.

Catalog record

CREATORMartynas Skrabulis 1,2, Martin Colombano Sosa 1,2, Nicola Carlon Zambon 3, Andrei Militaru 4, Massimiliano Rossi 5, Martin Frimmer 1,2, Lukas Novotny 1,2
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE22 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2601-19392

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Nanomechanical sensor resolving impulsive forces below its zero-point fluctuations Martynas Skrabulis 1,2, Martin Colombano Sosa 1,2, Nicola Carlon Zambon 3, Andrei Militaru 4, Massimiliano Rossi 5, Martin Frimmer 1,2, Lukas Novotny 1,2 Abstract The sensitivity of a mechanical transducer is ultimately limited by its inherent quantum fluctuations. Here, we use an optically levitated nanoparticle to measure impulsive forces smaller than the particle’s zero-point momentum uncertainty. Our approach relies on reversibly squeezing the levitated particle’s center-of-mass motion to coherently amplify the perturbation. We demonstrate resolving single impulsive-force kicks as small as 6.9 keV/c, a value 0.6 dB below the sensor’s zero-point value. Introduction. Mechanical transducers have played a pivotal role in unraveling the fundamental laws of nature 6 . Hallmark achievements based on mechanical transduction span from imaging individual molecular bonds in atomic force microscopy 17 to the detection of gravitational waves in kilometer-scale interferometers 1 . The key challenge associated with mechanical transduction is to measure the motion generated by the perturbation 5 . Optical readout schemes encode the transducer position into the phase of an electromagnetic probe field. The field’s quantum-mechanical nature limits the minimum readout noise via two contributions: measurement backaction and measurement imprecision 22 . Optimally balancing these two contributions leads to the “standard quantum limit” of continuous displacement and force sensing 11 ; 13 ; 14 ; 2 . At frequencies different from the oscillator’s resonance, this standard limit can be overcome by exploiting quantum correlations between the amplitude and phase quadrature of the probe after it interacted with the transducer (termed variational readout 14 ; 41 ; 37 ; 31 ; 29 ), or by using squeezed probe light with engineered quantum correlations 12 ; 26 . The resulting (ultimate) quantum limit is given by the inevitable zero-point motion of the transducer and poses a hard constraint for continuous position and force sensing 14 ; 22 . In recent years, instead of focusing on the probe field, engineered quantum correlations of the transducer’s motion have been leveraged 33 ; 21 ; 15 for sensing impulsive forces, i.e., instantaneous perturbations of the transducer’s momentum. Noiseless amplification by squeezing the vacuum fluctuations of the transducer has been demonstrated with ions 7 , which resemble microscopic mechanical oscillators when confined in radio-frequency traps. It is attractive to transfer such coherent amplification protocols 12 ; 25 ; 7 to much more massive systems. A prime target is an optically trapped dielectric nanoparticle ( \sim 10^{8} atomic mass units) 23 , which is a promising candidate to contribute to refinements of the standard model 49 ; 35 ; 10 . Proposals envision detecting collisions with hypothetical dark-matter particles 34 ; 9 , or unknown products of nuclear decays, with experimental efforts already underway 50 . Quantum control of levitated systems, a field termed levitodynamics, has made tremendous progress in recent years 23 . Optical trapping in ultra-high vacuum and efficient quantum measurement of the nanoparticle’s center-of-mass motion have enabled ground-state cooling using active feedback 30 ; 47 ; 28 and cavity cooling 18 ; 36 ; 38 . Furthermore, rapid modulation of the optical trapping potential has enabled the generation of squeezed states of mechanical motion 27 ; 39 . In this situation, it is enticing to exploit these quantum correlations to boost sensitivity to impulsive forces. In this work, we resolve impulsive forces acting on an optically levitated nanoparticle which are smaller than the particle’s zero-point fluctuations. We realize a coherent amplification protocol that relies on reversible and coherent squeezing operations, which we implement by rapidly switching the stiffness of the optical potential trapping the particle. Our system can resolve impulsive forces as small as 6.9\pm 0.8 keV/c, which is 0.6^{+0.6}_{-0.4} dB below the particle’s zero-point momentum fluctuations. Key concept. Figure 1: (a) Conventional impulsive-force sensing. Left: A harmonic oscillator is initialized to a Gaussian state centered in phase-space with momentum uncertainty \sigma_{P,i} (red). Right: An impulsive force translates the state by \Delta P along the momentum axis. Reading out the displaced state adds estimation uncertainty \sigma_{P,f} (blue). (b) Coherent amplification. Left: The harmonic oscillator is initialized as in (a). The momentum uncertainty is squeezed to \sigma_{P,i}/r (purple ellipse). Center: The impulsive force displaces the state by \Delta P along the momentum axis. Right: Anti-squeezing turns the momentum displacement \Delta P into a position displacement \Delta Q=r\Delta P . (c) Modulation sequence for oscillator resonance frequency. The frequency is temporarily stepped from \Omega to the reduced value \Omega/r to squeeze and subsequently anti-squeeze the oscillator. The impulsive force acts at the time of maximum momentum squeezing. Let us revisit the standard protocol for impulsive force sensing. A harmonic oscillator (mass m , eigenfrequency \Omega ) with position z and momentum p is initialized in a Gaussian state, centered at the origin of phase space, as illustrated in Fig. 1 (a). Let Q=z/z_{\text{zp}} and P=p/p_{\text{zp}} be the phase-space coordinates normalized by their respective zero-point values z_{\text{zp}}=\sqrt{\hbar/(2m\Omega)} and p_{\text{zp}}=\sqrt{\hbar m\Omega/2} . Let the initial position variance \sigma_{Q,i}^{2} and momentum variance \sigma_{P,i}^{2} be equal [red in Fig. 1 (a)]. An impulsive force acting on the oscillator shifts the state along the momentum axis by the transferred momentum \Delta P . The smallest measurable \Delta P is given by the total variance \sigma^{2}_{P,\text{tot}}=\sigma_{P,i}^{2}+\sigma_{P,f}^{2} , where the second term represents the uncertainty with which the final state can be localized in phase space by subsequent measurements, illustrated in blue in Fig. 1 (a). We now turn to describing the coherent amplification protocol 12 ; 25 ; 7 adapted to a levitated oscillator system. We modulate oscillator’s eigenfrequency in a step-like fashion as illustrated in Fig. 1 (c). With the oscillator initialized as in the standard protocol, we step the eigenfrequency from the initial value \Omega to \Omega/r , with r>1 , at time t=-\pi r/\Omega . In the softer potential, points in phase space move on ellipses elongated along the position axis. Specifically, at time t=-\pi r/(2\Omega) , the initially circular state is maximally squeezed along the momentum axis, with variance \sigma_{P,i}^{2}/r^{2} , and anti-squeezed along the position axis, with variance r^{2}\,\sigma_{Q,i}^{2} , as illustrated in Fig. 1 (b, left). An impulsive force arriving at t=-\pi r/(2\Omega) displaces this squeezed state along the momentum axis by \Delta P (center panel). Further evolution in the weaker potential for another quarter period, until t=0 , reverses the squeezing operation, leaving the state with the initial variances \sigma_{P,i}^{2}=\sigma_{Q,i}^{2} (right). Importantly, the momentum displacement \Delta P is turned into a position displacement \Delta Q=r\,\Delta P , which is boosted by r during the anti-squeezing step. Therefore, embedding the impulsive force between the squeezing and anti-squeezing operations amplifies the signal produced by the impulsive force without adding additional uncertainty. In the following, we experimentally realize this coherent amplification protocol with an optically levitated nanoparticle. Experimental setup. Figure 2: Experimental setup. A focused laser generates an optical trap for a dielectric nanoparticle in ultra-high vacuum (UHV). The backscattered light is mixed with a local oscillator (LO) to detect the particle motion along the z axis. This position signal is used for feedback (FB) cooling. The optical trapping potential is modulated with an acousto-optic modulator (AOM). An impulsive force \Delta P is imparted by applying a voltage pulse of duration \tau

Read the complete text