Coronary Artery Segmentation and Vessel-Type Classification in X-Ray Angiography
Mehdi Yousefzadeh, Siavash Shirzadeh Barough, Ashkan Fakharifar, Yashar Tayyarazad, Narges Eghbali, Mohaddeseh Mozaffari, Hoda Taeb, Negar Sadat Rafiee Tabatabaee, Parsa Esfahanian, Ghazaleh Sadeghi Gohar, Amineh Safavirad, Saeideh Mazloomzadeh, Ehsan khalilipur, Armin Elahifar, Majid Maleki · 2026
Read Coronary Artery Segmentation and Vessel-Type Classification in X-Ray Angiography by Mehdi Yousefzadeh, Siavash Shirzadeh Barough, Ashkan Fakharifar, Yashar Tayyarazad, Narges Eghbali, Mohaddeseh Mozaffari, Hoda Taeb, Negar Sadat Rafiee Tabatabaee, Parsa Esfahanian, Ghazaleh Sadeghi Gohar, Amineh Safavirad, Saeideh Mazloomzadeh, Ehsan khalilipur, Armin Elahifar, Majid Maleki (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-17429.txt.
Introduction
Mehdi Yousefzadeh and four co-authors tackle vessel maps in X-ray angiography. That imaging is the clinical standard for coronary artery disease. Yet measuring vessels in routine scans is hard. Low contrast, motion, and overlap blur the arteries. Catheters add false shapes. Centers also differ, which shifts the data. The team works on two tasks at once.
They segment the coronary arteries from the background. They also classify vessel type along the tree. Both tasks must hold up in real clinic data. Good maps guide stent and surgery choices. Robust tools could cut the hand work that slows reads. The study targets the flaws that block daily use.
Catalog record
| CREATOR | Mehdi Yousefzadeh, Siavash Shirzadeh Barough, Ashkan Fakharifar, Yashar Tayyarazad, Narges Eghbali, Mohaddeseh Mozaffari, Hoda Taeb, Negar Sadat Rafiee Tabatabaee, Parsa Esfahanian, Ghazaleh Sadeghi Gohar, Amineh Safavirad, Saeideh Mazloomzadeh, Ehsan khalilipur, Armin Elahifar, Majid Maleki |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 45 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2601-17429
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Coronary Artery Segmentation and Vessel-Type Classification in X-Ray Angiography Mehdi Yousefzadeh, Siavash Shirzadeh Barough, Ashkan Fakharifar, Yashar Tayyarazad, Narges Eghbali, Mohaddeseh Mozaffari, Hoda Taeb, Negar Sadat Rafiee Tabatabaee, Parsa Esfahanian, Ghazaleh Sadeghi Gohar, Amineh Safavirad, Saeideh Mazloomzadeh, Ehsan khalilipur, Armin Elahifar, Majid Maleki Abstract Introduction. X-ray coronary angiography (XCA) is the clinical reference standard for assessing coronary artery disease, yet quantitative analysis is limited by the difficulty of robust vessel segmentation in routine data. Low contrast, motion, foreshortening, overlap, and catheter confounding degrade segmentation and contribute to domain shift across centers. Reliable segmentation, together with vessel-type labeling, enables vessel-specific coronary analytics and downstream measurements that depend on anatomical localization. Methods. From 670 cine sequences (407 subjects), we select a best frame near peak opacification using a low-intensity histogram criterion and apply joint super-resolution and enhancement. We benchmark classical Meijering/Frangi/Sato pipelines under per-image oracle tuning, a single global mean setting, and per-image prediction via Support Vector Regression (SVR) from a 140-D descriptor. Neural baselines include U-Net and FPN (SE-ResNet18/SE-ResNeXt50) and a Swin-Transformer at 384 × 384 384\times 384 or 756 × 756 756\times 756 , trained with coronary-only, catheter-only, and merged coronary+catheter supervision. A second stage assigns vessel identity (LAD/LCX/RCA). External evaluation uses the public DCA1 cohort. Results. SVR per-image tuning improves Dice over global means for all classical filters (Meijering: 0.703 vs. 0.698; Sato: 0.719 vs. 0.710; Frangi: 0.759 vs. 0.741). Among deep models, FPN+SE-ResNet18 at 756 × 756 756\times 756 attains 0.914 ± 0.007 0.914\pm 0.007 (coronary-only), and merged coronary+catheter labels further improve to 0.931 ± 0.006 0.931\pm 0.006 (catheter-only: 0.856 ± 0.031 0.856\pm 0.031 ). On DCA1 as a strict external test, Dice drops to 0.798 (coronary-only) and 0.814 (merged), while light in-domain fine-tuning recovers to 0.881 ± 0.014 0.881\pm 0.014 and 0.882 ± 0.015 0.882\pm 0.015 . Vessel-type labeling achieves accuracy/DSC of 98.5%/0.844 (RCA), 95.4%/0.786 (LAD), and 96.2%/0.794 (LCX). Conclusion. Machine-learning generalized image processing and deep neural segmentation provide accurate coronary segmentation and vessel-type labeling in XCA. Learned per-image tuning strengthens classical pipelines, while high-resolution FPN models and merged-label supervision improve stability and external transfer with modest adaptation. Keywords X-Ray Angiography \cdot Coronary Arteries Segmentation \cdot Vessel-Type Labeling \cdot Fractional Flow Reserve 1 Introduction Coronary angiography is the clinical reference standard for diagnosing and characterizing coronary artery disease (CAD), providing high-fidelity visualization of lumen narrowing to guide revascularization and other life-saving interventions 10 . It plays a central role across a wide range of CAD presentations, including acute myocardial infarction, unstable angina, and ischemic heart disease, and it informs the choice between percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) 29 . Cardiovascular disease remains a leading global cause of death, and the burden of CAD motivates robust, scalable tools for angiographic assessment 38 . Coronary artery segmentation is a core component of quantitative angiographic analysis. It enables objective assessment of stenosis severity, supports visualization of contrast flow patterns, and provides a foundation for downstream functional estimates such as fractional flow reserve (FFR) surrogates 27 ; 43 . In practice, accurate segmentation is challenging because angiograms often exhibit low contrast, motion artifacts, foreshortening, and vessel overlap. Interventional devices such as catheters can further confound vessel delineation, increasing the difficulty of both manual assessment and automated methods 30 ; 46 . These challenges contribute to variability among readers and can be particularly consequential in borderline lesions. A range of classical approaches has been explored to improve vessel visibility prior to segmentation. Statistical methods have been used to describe intensity distributions through histogram-based descriptors and probability density estimation, with the goal of enhancing contrast and outlining vessel boundaries 32 ; 15 . Other work has quantified spatial dependencies in vascular trees using correlation functions across scales 33 ; 36 . Entropy-based criteria, including maximum-entropy approaches and generalized divergences such as Jensen–Shannon, have been applied to capture image complexity and guide adaptive thresholding 1 ; 17 . These descriptors often appear in multi-stage pipelines that combine enhancement operations such as unsharp masking and CLAHE with filter-based feature extraction 41 ; 12 . More recently, non-parametric density estimation and adaptive entropy imaging have been proposed to mitigate histogram binning limitations and improve delineation of small vessels 7 ; 44 . Deep learning has substantially advanced automated segmentation in medical imaging through end-to-end feature learning and multi-scale representations 21 . U-Net and its variants introduced encoder–decoder designs with skip connections that preserve spatial detail under limited annotation budgets 31 ; 45 . Auto-configuring pipelines such as nnU-Net demonstrated strong performance across many segmentation tasks by adapting training and architectural choices to the dataset 16 . Attention mechanisms and hybrid CNN–Transformer models further improved performance by emphasizing salient anatomy and capturing longer-range context 28 ; 2 ; 22 . In coronary angiography, these models can be highly accurate, but performance can depend strongly on input resolution, supervision design, and domain shift across centers and acquisition protocols. Despite progress, coronary angiography segmentation remains difficult to standardize. Many published results rely on small cohorts, different preprocessing choices, and inconsistent evaluation protocols. Public datasets such as DCA1 provide valuable benchmarks, but they typically offer binary vessel masks, which limits analysis of device interference and does not support vessel-level labeling required for vessel-specific downstream analysis 5 . In parallel, classical vesselness filters based on the Hessian matrix remain relevant due to their strong inductive bias for tubular structures. Methods such as Frangi, Meijering, and Sato have been widely used, and broader benchmarking across modalities has shown that their performance is sensitive to parameter choices and imaging characteristics 11 ; 25 ; 34 ; 19 . In coronary angiography specifically, Hessian-based pipelines have been used in combination with enhancement, region merging, and region growth strategies, reporting competitive Dice values in some settings 40 ; 18 ; 23 . This work aims to provide a unified and practical study of coronary segmentation and vessel-type classification in X-ray coronary angiography (XCA). We curate an expert-reviewed dataset with separate coronary and catheter masks, as well as vessel-level labels for the major coronaries (LAD, LCX, RCA). We benchmark classical vesselness pipelines and modern deep models under a consistent preprocessing and evaluation protocol. For classical methods, we go beyond fixed global hyperparameters by learning to predict per-image filter settings from inexpensive image descriptors using support vector regression (SVR), which improves robustness without requiring ground-truth masks at inference time. For deep models, we compare U-Net, feature pyramid networks (FPN), and a hierarchical Transformer baseline, and we study the impact of supervision design by training with coronary-only, catheter-only, and merged coronary+catheter targets. Finally, we introduce a second-stage model that assigns vessel identity within the segmented coronary tree, bridging segmentation outputs with vessel-specific downstream analysis. Here are the key contributions of our work: • Curated a new dataset with expert-reviewed labels, including separate masks for coronary arteries and catheter, plus vessel-level masks (LAD, LCX, RCA). • Systematically benchmarked classical vesselness pipelines against each other and against neural segmentation models under a unified protocol. • Enhanced classical pipelines via a learning-to-tune strategy that predicts per-image hyperparameters using SVR, improving robustness without ground-truth labels at inference. • Conducted a controlled study of label design, comparing coronary-only, catheter-only, and merged coronary+catheter supervision, and quantified the impact of