Wind-turbine wake effects on the rate of accumulation of fatigue damage in overhead conductors

Francisco J. G. de Oliveira, Kevin Gouder, Zahra Sharif Khodaei, Oliver R. H. Buxton · 2026

Read Wind-turbine wake effects on the rate of accumulation of fatigue damage in overhead conductors by Francisco J. G. de Oliveira, Kevin Gouder, Zahra Sharif Khodaei, Oliver R. H. Buxton (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-17327.txt.

Introduction

Francisco J. G. de Oliveira and three co-authors study a risk where wind farms meet power lines. A turbine wake is a zone of churned air behind the blades. That churn can shake overhead conductors. Shake builds fatigue damage over time. Rules for safe gaps vary by country. In the United Kingdom, lines should stay at least three rotor widths away.

The team measures how wakes change the rate of fatigue build-up. Proof like that can firm up rules that now rest on caution. Too small a gap risks line failure. Too large a gap wastes land near farms. Their work helps planners set gaps with data in hand.

Catalog record

CREATORFrancisco J. G. de Oliveira, Kevin Gouder, Zahra Sharif Khodaei, Oliver R. H. Buxton
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE75 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2601-17327

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Wind-turbine wake effects on the rate of accumulation of fatigue damage in overhead conductors Francisco J. G. de Oliveira, Kevin Gouder, Zahra Sharif Khodaei, Oliver R. H. Buxton Abstract Guidance relating to the safe distance within which overhead conductors (OHCs) should not be built with respect to a wind turbine, and vice versa, varies from country to country. In the United Kingdom the recommendation is that OHCs are not installed within three rotor diameters (3 D D ) of wind turbines due to concerns over wake-induced fatigue. To assess the physical basis for this recommendation, wind-tunnel experiments were conducted using a scaled wind turbine placed upstream of an instrumented conductor, in conditions representative of forested terrain. The conductor was equipped with distributed fibre-optic strain sensing based on Rayleigh backscattering, providing spatially resolved measurements at 2.6 mm resolution. Three conductor heights and four turbine-conductor spacings were tested, together with a no-turbine baseline, while maintaining a constant incident wind speed of 7 m s -1 . The results identify a critical region near the clamp where mean strain is maximised. Neither mean nor fluctuating strain at this location increased substantially due to the presence of the turbine wake. Strain fluctuations were dominated by aeolian vibration, with the wake increasing vibration amplitude whilst reducing its characteristic frequency. Rainflow counting fatigue analysis shows that damage accumulation depends strongly on conductor height. While fatigue damage rates increase when the conductor is fully immersed in the wake, reduced damage rates are observed for lower heights and closer spacings. These results suggest that, under forested atmospheric conditions, conductor-turbine separations smaller than the current 3 D D guidance may be feasible provided the conductor is not fully immersed in the turbine wake. 1 Introduction The adoption of net zero targets for carbon dioxide emissions worldwide will increase the demand for electricity, driven by electrification of sectors such as transport, heating, and industrial processes. For example, it is estimated that electricity demand in the United Kingdom will increase between 44% and 150% by 2050 due to net-zero technological roll outs [ 4 ] . In addition, the advent of artificial intelligence and the need for energy intensive data centres will further increase this demand with the UK’s National Energy System Operator (NESO) estimating that demand from data centres will grow from 5 TW hrs annually in 2024 to 22 TW hrs by 2030 [ 28 ] . Whilst these numbers specifically refer to the UK these trends are repeated worldwide. At the same time that demand for electricity is increasing there is a transition towards renewable energy generation sources. Wind and solar energy dominate, with the Global Wind Energy Council’s 2025 Global Wind Report [ 17 ] revealing that a record 117 GW of wind power was installed worldwide in 2024 (109 GW onshore) taking the global installed wind capacity to 1,136 GW of which the overwhelming majority (1,052 GW) is installed onshore. It is thus clear that these pressures will lead to the construction of new overhead transmission lines in proximity to onshore wind turbines, and vice versa, especially in locations with an abundant wind resource such as Scotland. Since wind turbines harness kinetic energy from the wind they leave a wake downstream, which is a region in which there is a kinetic-energy, and hence momentum deficit in comparison to the unimpeded wind. The phenomenology of wind-turbine wakes is complex with excellent overviews given by 36 and 35 . Broadly, they can be divided into two distinct regions, i) the near wake where coherent motions yielded by the blade-tip vortex system, the blade-root vortex system, and the vortex shedding initiated by the nacelle and tower interact with one another [ 7 , e.g.] , and ii) the far wake in which these coherent motions have largely dissipated and the velocity profile of the wake can be approximated through a Gaussian superimposed onto the incoming atmospheric boundary layer (ABL) profile [ 5 , e.g.] . The transition between the near wake and far wake is complex and depends upon the break down of the dominant coherent motions within the wake such as the tip vortex system [ 24 , e.g.] . It is also dependent on operating conditions, e.g. the turbine’s tip-speed ratio [ 7 ] , TSR, \Lambda=\Omega D/(2U_{\infty}) where \Omega is the rotational speed of the turbine, D is the turbine’s diameter, and U_{\infty} is the incident wind speed, which is the ratio of the solid-body rotational speed of the blade tip to the oncoming wind velocity. Nevertheless, a good overview of the different phenomenologies of the near wake, transition region, and far wake and where these transitions typically take place is given in 30 . It is important to note that the turbulence level (turbulence intensity I ) in the incoming flow is an important determinant of where these transitions take place since all wind turbines are situated within the turbulent ABL. The wake’s momentum deficit is at its largest closest to the rotor plane (in the near wake) and then decreases with distance downstream due to the entrainment, and mixing of higher momentum air into the wake [ 31 , 2 , 9 , e.g.] . Since the Reynolds number, the ratio between inertial and viscous forces in a fluid flow, is high for these wakes (typically Re_{D}\sim\mathcal{O}(10^{7}-10^{8}) for a utility-scale wind turbine) these wakes are turbulent. An overhead conductor (OHC) situated within the wake of a wind turbine is thus exposed to a highly unsteady turbulent inflow in which the incident velocity is lower than the unimpeded wind. Both of these can accelerate the accumulation of fatigue damage in the OHC and lead to premature failure. Firstly, the unsteady inflow, which varies according to the spectrum of the turbulent motion, yields a fluctuating drag force on the OHC and hence vibration parallel to the wind vector. This process is known as turbulent buffeting [ 38 , e.g.] . All OHCs are exposed to turbulent buffeting due to the turbulent nature of the ABL, but the additional wake-turbulence present in a wind-turbine wake can be plausibly expected to modify the buffeting experienced by an OHC situated with an impinging wind-turbine wake. Secondly, a reduced incident wind velocity (due to an impinging wind-turbine wake) can yield a phenomenon known as aeolian vibration (or alternatively vortex-induced vibration [ 8 ] ) . All OHCs are functionally high aspect ratio cylinders with respect to the incident flow and therefore shed vortices, via a von Kármán vortex street, which induces an unsteady lift force (perpendicular to the wind vector) on the cable. The non-dimensional frequency (Strouhal number) at which these vortices are shed, St_{VS}=f_{VS}d/U_{w} – where f_{VS} is the vortex shedding frequency, d is the cable diameter, and U_{w} is the incident wind speed on the cable – is a function of the Reynolds number of the flow incident on the cable Re_{d} . Various aerodynamic regimes, parameterised by St_{VS} and Re_{d} , exist for typical combinations of wind speed and cable diameter yielding vortex shedding in the range 0.17\lesssim St_{VS}\lesssim 0.21 [ 15 ] . When this vortex shedding approaches the natural frequency of the cable due to its own inertia/tension then a resonance can be produced that

Read the complete text