Instrument Science Report STIS 2025-01(v1)

STIS Cycle 30 Calibration Programs · 2026

Read Instrument Science Report STIS 2025-01(v1) by STIS Cycle 30 Calibration Programs (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-17159.txt.

Introduction

The STIS Cycle 30 team reports a year of checks on a Hubble scope tool. STIS is a light-split tool on the Hubble Space Telescope. Its marks must stay true for science to hold. The team's 2026 report covers late 2022 to late 2023. Nineteen set check plans ran in that span. Each plan's aims, shots, and results get a short brief.

Past years' marks set the bar for each check. Gaps twixt aim and mark get flagged with care. Notes point to deep reads for each plan. Such reports keep a famed scope's facts on firm ground. All Hubble users lean on that ground.

Catalog record

CREATORSTIS Cycle 30 Calibration Programs
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE44 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2601-17159

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Instrument Science Report STIS 2025-01(v1) STIS Cycle 30 Calibration Programs Abstract A BSTRACT We discuss the suite of STIS calibration programs executed during HST Cycle 30, covering the period 2022 Nov 07 through 2023 Nov 05. For each of the 19 current regular calibration programs, we provide brief descriptions of the objectives, observations, analysis procedures, and results – with comparisons to the results from previous cycles and to desired accuracies, as well as references to more detailed analyses of the calibration data. Many of these calibration programs produce routine reference file deliveries or demonstrate the continuing applicability of existing reference files for processing STIS observations. This ISR provides a brief snapshot of the current instrument performance, similar to those given in annual reports for Cycles 7–10 and 17–21. Two Appendices briefly discuss the state of the onboard calibration lamps and the ongoing major effort to revise the flux calibration for the many STIS spectroscopic and imaging modes. Contents Introduction During each Hubble Space Telescope (HST) cycle, the Space Telescope Imaging Spectrograph (STIS) team executes a set of regular calibration programs designed to monitor the health and performance of the three STIS detectors and other instrumental components. Special calibration programs, designed to address specific issues, may also be implemented during individual cycles. The quantitative data from these programs are used to generate reference files characterizing the instrumental behavior, which are used for both calstis pipeline reductions of STIS science data and for predicting instrumental performance with the STIS Exposure Time Calculator (ETC). While the behavior of STIS is at this point fairly stable and well understood, some characteristics have been evolving with time – e.g., detector sensitivity (as a function of wavelength), dark count rates, wavelength calibration, detector cosmetics, the brightness of the calibration lamps, and other, more subtle properties. The behavior of STIS can also be affected if the instrument is shut down for more than several days (e.g., during an extended “safing” of the observatory). Such changes can be seen both in data obtained for the calibration programs and in science data obtained and analyzed by guest observers. This document provides a brief description of the current state of the instrument, based primarily on analyses of the calibration observations carried out during HST Cycle 30, nominally covering the period 2022 Nov through 2023 Oct (though more recent results are noted in a few cases). The current suite of regular (generally annual) calibration programs is also fairly stable. While the current set of programs is not as extensive as those executed during the original commissioning period (Cycle 7) or during the re-commissioning following the repair of STIS in Servicing Mission 4 (Cycle 17; STIS ISR 2013-04 ), a number of the programs that have continued are fairly similar to their predecessors. In a number of cases, minor changes have been made over the years – to adjust for decreasing detector sensitivities or the fading of the internal calibration lamps, to monitor additional instrumental characteristics, or (in some cases) to reduce the number of specific modes that are monitored. In Cycle 30, a program to monitor the three primary white dwarf flux standard stars – which had executed as a special calibration program in several previous cycles – was added to the regular suite, to be run every other cycle. No special calibration programs were executed during Cycle 30. There were only three short ( \sim 1 day) “safing” events during Cycle 30 (2023 Aug 08, 2023 Aug 12, 2023 Aug 28), none of which lasted long enough to significantly affect the behavior of the STIS detectors. The 19 programs in the current calibration suite are listed in Table Introduction , with the Cycle 30 PI, the number of external and internal orbits used, and an indication of the frequency of execution. Only five of the programs obtain spectroscopic or imaging data for external targets – either individual flux standard stars or standard stellar fields. The other 14 programs execute in “internal” orbits – either observing one of the onboard calibration lamps or no source at all (e.g., observations of the bias and dark rates). The entire Cycle 30 STIS calibration program used 1342 internal orbits and 26 external orbits. Brief discussions of several issues related to the STIS calibration program are presented in two Appendices. Appendix A provides some information regarding the current state of the onboard calibration lamps. Appendix B describes the extensive effort underway to refine the flux calibration of the various STIS spectroscopic and imaging modes, in response to recent improvements in stellar models. For more details regarding particular calibration programs and issues, users may consult the following resources: STIS Instrument Handbook STIS Data Handbook STIS Instrument Science Reports – some listed in the references (below) STIS calibrations page – and the individual phase II proposals linked there STIS performance web page – instrumental characteristics and monitoring HST Calibration Reference Data System (CRDS) – reference files HST HelpDesk Table 1 : STIS Cycle 30 Calibration Programs \begin{array}[c]{\string cllccc}{\hline}{}\cr{\vskip-5.85553pt}{}\hfil PID\hfil\hfil Program\hfil\hfil PI\hfil\hfil ExtOrbits\hfil\hfil IntOrbits\hfil\hfil Frequency\hfil\hskip 4.0pt{}\vrule height=0.0pt,depth=2.41109pt,width=0.0pt\cr{}{\hline}{}\cr{\vskip-5.16666pt}{}\par 16945CCDPerformanceMonitorS.Lockwood0142x/yr{}\cr{\vskip 0.0pt}{}16946-48CCDDarkMonitorS.Medallon07282x/day{}\cr{\vskip 0.0pt}{}16949-50CCDBiasandReadNoiseMonitorS.Lockwood0364daily{}\cr{\vskip 0.0pt}{}16951CCDHotPixelAnnealingS.Medallon03913x/yr{}\cr{\vskip 0.0pt}{}16944CCDSpectroscopicFlatFieldMonitorJ.Carlberg019~monthly{}\cr{\vskip 0.0pt}{}16952CCDImagingFlatFieldMonitorD.Welty044x/yr{}\cr{\vskip 0.0pt}{}16954CCDSpectroscopicDispersionSolutionMonitorD.Welty031x/yr{}\cr{\vskip 0.0pt}{}16953CCDSparseFieldCTES.Lockwood0501x/yr{}\cr{\vskip 0.0pt}{}16955CCDFullFieldSensitivityMonitorS.Lockwood101x/yr{}\cr{\vskip 0.0pt}{}16957CCDSpectroscopicSensitivityMonitorS.Hernandez504x/yr{}\cr{\vskip 0.0pt}{}16958SlitWheelRepeatabilityA.Jones011x/yr{}\cr{\vskip 0.0pt}{}16959MAMASpectroscopicDispersionMonitorD.Welty071x/yr{}\cr{\vskip 0.0pt}{}16956MAMAFullFieldSensitivityMonitorS.Lockwood301x/yr{}\cr{\vskip 0.0pt}{}16960MAMASpectroscopicSensitivityandFocusMonitorS.Hernandez1208x/yr{}\cr{\vskip 0.0pt}{}16961FUVMAMADarkMonitorS.Lockwood0489x/yr{}\cr{\vskip 0.0pt}{}16962NUVMAMADarkMonitorA.Jones052bi-weekly{}\cr{\vskip 0.0pt}{}16963FUVMAMAFlatFieldMonitorA.Jones01111x/yr{}\cr{\vskip 0.0pt}{}16964MAMAFoldDistributionT.Wheeler021x/yr{}\cr{\vskip 0.0pt}{}16966MonitoringtheThreePrimaryWDStandardStarsR.Bohlin501x/yr{}\cr{\vskip 0.0pt}{}{\hline}total261342{}\cr{\vskip 0.0pt}{}\crcr{\vskip 2.41109pt}{\hline}\lx@close@alignment\end{array}\end@float\par\par\lx@newpage CCD Performance Monitor (16945; S. Lockwood / M. Dallas) Objectives: This program monitors the overall baseline performance of the STIS CCD. Observations: Full frame bias and flat field (imaging and spectroscopic) exposures are taken in order to measure read noise, charge transfer efficiency (CTE), spurious charge, and gain. Different apertures and exposure times are used for the flat fields; gain=1,2,4,8 are used for the imaging flats and the bias exposures. Bias frames are also taken in subarrays to check the bias level for ACQ and ACQ/PEAK observations. All exposures use amplifier D. The data were obtained in two sets of seven internal orbits, in March and September of 2023. Analysis: Determinations of the read noise and CTE are discussed below, under the more specific programs monitoring those effects. More detailed discussions of the analysis of CCD performance data may be found in STIS ISR 2009-02 , which describes the behavior of the STIS CCD just after SM-4, and STIS ISR 2017-05 . Results: Up-to-date plots of the CCD housing temperature (from engineering telemetry) and read noise are available on the main STIS monitors web pages. Plots of the CTE, spurious charge, and various other quantities are available at https://www.stsci.edu/ \sim STIS/monitors . Overall, the various measures of CCD behavior remain consistent with recent trends. The CCD housing temperature (thought to be the best currently available proxy for the detector temperature) is typically of order 21 \pm 2 K. Both parallel and serial charge transfer inefficiency (CTI = 1 - CTE) continue their slow increase (Fig. 1 ); the current CTI values, as measured by the Extended Pixel Edge Response (EPER) method, are \sim 0.073% and \sim 0.0024%, respectively. “Spurious charge” refers to structure along the CCD columns, thought to be due to charge leakage from hot pixels – thus increasing as the CCD accumulates radiation damage. At the central row in the bias frames, the spurious charge is currently \sim 1.8 e - /pix for gain=1 and \sim 8.3 e - /pix for gain=4, and is somewhat lower at

Read the complete text