Precise Low-Current Measurement Techniques for IoT Devices: A Case Study on MoleNet
Julian Block, Andreas Könsgen, Jens Dede, Anna Förster · 2026
Read Precise Low-Current Measurement Techniques for IoT Devices: A Case Study on MoleNet by Julian Block, Andreas Könsgen, Jens Dede, Anna Förster (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-16727.txt.
Introduction
Julian Block, Andreas Könsgen, Jens Dede, and Anna Förster measure tiny power draws with care. Small web-linked gear must run for months on one cell. To plan that life, teams must gauge sleep-state draws. Those draws are far too small for plain tools. Their 2026 preprint tests fine gauge tricks on a real node.
Their test case is MoleNet, a net of small sense nodes. Bench tools like scopes blur at such low draws. The team weighs which tricks stay true at that scale. Sharp gauges help teams fix leaks in code and gear. Long cell life then serves farms, woods, and smart homes.
Catalog record
| CREATOR | Julian Block, Andreas Könsgen, Jens Dede, Anna Förster |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 24 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2601-16727
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Precise Low-Current Measurement Techniques for IoT Devices: A Case Study on MoleNet Julian Block, Andreas Könsgen, Jens Dede, Anna Förster Abstract Power consumption is a crucial aspect of IoT devices which often have to run on a battery for an extended period of time. Therefore, supply current measurements are crucial before deploying a device in the field. Multimeters and oscilloscopes are not well suited when it comes to measuring very small currents which occur e.g. when an IoT device is in sleep mode. In this report, we compare dedicated source measurement units (SMUs) which allow to measure very small currents with high precision. As an application example, we demonstrate current measurements on our MoleNet IoT sensor board. I Introduction The Internet of Things is rapidly gaining popularity, IoT devices are meanwhile deployed in various types of applications. In many cases, these devices are however placed at locations where they cannot be easily maintained, such as underground, underwater, or in remote locations where human operators are not available frequently. Therefore, it is crucial that such devices which usually run on batteries have a long lifetime so that a long service interval is possible. In this regard, extensive power measurements should be taken before a device is deployed in the field to get an overview about the power consumption so that the battery size can be adapted or the hard-/software of the device can be tuned in order to minimize the power consumption. Since the supply voltage of the device is in general constant, the power measurement reduces to a current measurement. IoT devices are designed to go to sleep when not sensing or transmitting data, the sleep current is reduced to a few microamperes in order to maximize battery lifetime. Multimeters are not designed to measure such small currents with high precision or resolution. Since multimeters internally measure a voltage, currents are converted using a shunt resistor where a voltage drop a.k.a. burden voltage occurs which can be a few hundred millivolts, dependent on the most sensitive measurement range of the instrument. Using oscilloscopes for the measurements is attractive in order to easily get a graphical display of the current, however such devices only measure voltages, again in the region of a few hundred millivolts. Because of the aforementioned restrictions of measurement instruments, it is desired to convert even very small currents into a voltage which is sufficiently high to be properly measured, while at the same time keeping the burden voltage in the region of a few millivolts, in contrast to hundreds of millivolts required by normal measurement devices as previously said. For this purpose, source measurement units (SMUs) are available which measure the voltage drop across a shunt and use a precision amplifier so that a small burden voltage is sufficient for the measurement and the resistance of the shunt can be kept small. Since we widely work with IoT devices in our department, we need to frequently measure current intakes and therefore had a comprehensive survey on SMUs which we present in this report. II Tested Devices There are two basic types of SMUs: Add-on devices provide an analog output voltage. Therefore, the time resolution of the measurement depends on the speed of the A/D converter which is built into the external instrument. For bench-top multimeters, the rate is a few hundred samples per second, whereas for oscilloscopes, the rate may be up to the gigasamples per second range. Standalone SMUs include an A/D converter and a display in order to output the measured values. The time resolution of the measurement depends on the sample rate of the device’s ADC. In the following overview, some notable features of the tested SMUs are highlighted. The technical specifications are available in Table I . II-A Add-on devices The µCurrent GOLD available from the EEVblog online store 1 1 1 eevblog.store/collections/test-equipment , Accessed: 2026-01-23 is an add-on device which converts the measured current into a voltage with a range large enough to be properly measured by an external meter. It features a pair of banana sockets for the current to be measured and another pair for the output voltage. For measurements with an oscilloscope, a banana-to-BNC adapter is required. A switch allows the selection between three different measurement ranges. The device is powered by a 3 V coin cell. There is an indicator when the battery voltage drops too low in order to ensure reliable measurements. It should be noted that the device does not use fuses as overload protection for the current measurement in order to avoid an additional voltage drop. This however means that the shunt resistor used for the current measurement may be damaged if the measured current is too high. The design of the µCurrent GOLD is open-source [ 2 ] . A follow-up to the µCurrent GOLD is the tinyCurrent available e.g. in the n-fuse store 2 2 2 www.n-fuse.co/devices/tinyCurrent-precision-low-Current-Measurement-Shunt-and-Amplifier-Device.html , Accessed: 2026-01-23 . An important enhancement w.r.t. the µCurrent is an additional BNC connector for the output voltage to connect an oscilloscope through a coaxial cable without additional adapter. The shielding of the coaxial cable is important when measuring signals with high time resolution because interference is reduced. There is also a version with an inverted BNC connector available which connects directly to the oscilloscope without a cable in between. A second novelty of the tinyCurrent is a connector for an external power supply, which is useful for long-term measurements where the coin-cell battery would not suffice. The tinyCurrent is also Open Source [ 1 ] . II-B Stand-alone devices The CurrentRanger is again a further development of the tinyCurrent. It is extended by automatic measurement range selection, A/D conversion, data logging and an OLED display so that it also can be operated without an external measurement device. It is powered by a rechargeable lithium polymer (LiPo) battery. The software is open source which is useful, e.g., if the automatic range selection should be tuned. This can happen if the device under test has a rapidly changing current intake. If the current gets too high because of a sudden increase of the current, the device runs into a brown-out until the shunt resistor is changed. Altering the software source code allows to change the speed at which the measurement range should be changed or to disable it altogether. Also, for long-term measurements, the automatic power-off function can be disabled. A USB port allows for the connection of the device to a computer for data logging. One should use the USB port with care, since the ground of the USB connector is not separated from the rest of the circuitry. Wrong usage may damage the CurrentRanger, therefore inserting a USB isolator between the Current Ranger and the computer is recommended [ 8 ] . The µSMU is a four-quadrant device and therefore suitable both as a source and sink for positive and negative currents. The output can be read through a USB interface; again a USB isolator may be needed dependent on the usage conditions as mentioned above. The device is open source, Python code to control the unit from the computer is available on GitHub 3 3 3 github.com/joeltroughton/uSmU , Accessed: 2026-01-23 . The Nordic