Assessment of Errors of Fundamental Frequency Estimation Methods in the Presence of Voltage Fluctuations and Distortions

Antonio Bracale, Pasquale De Falco, Piotr Kuwałek, Grzegorz Wiczyński · 2026

Read Assessment of Errors of Fundamental Frequency Estimation Methods in the Presence of Voltage Fluctuations and Distortions by Antonio Bracale, Pasquale De Falco, Piotr Kuwałek, Grzegorz Wiczyński (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-16606.txt.

Introduction

Antonio Bracale and three coauthors weigh flaws in base tone reads when volts waver. Their 2026 preprint deals with power grade on new grids. Base tone, the mains wave rate, is a key grade mark. True reads of it in short spans guide grid checks. New grids waver in volts far more than old grids did.

Waver bends tone reads in ways teams must count. The team tests read ways side by side in such terms. Each way is scored by its flaw size in short spans. Low flaw ways help grid teams spot faults fast. The work serves checks of grid health in real time.

Catalog record

CREATORAntonio Bracale, Pasquale De Falco, Piotr Kuwałek, Grzegorz Wiczyński
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE21 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2601-16606

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Assessment of Errors of Fundamental Frequency Estimation Methods in the Presence of Voltage Fluctuations and Distortions Thanks: This research was funded in whole or in part by National Science Centre, Poland – 2024/55/D/ST7/00441. For the purpose of Open Access, the author has applied a CC BY public copyright licence to any Author Accepted Manuscript (AAM) version arising from this submission. Antonio Bracale, Pasquale De Falco, Piotr Kuwałek, Grzegorz Wiczyński Abstract The fundamental frequency is one of the parameters that define power quality. Correctly determining this parameter under the conditions that prevail in modern power grids is crucial. Diagnostic purposes often require an efficient estimation of this parameter within short time windows. Therefore, this article presents the results of numerical simulation studies that allow the assessment of errors in various fundamental frequency estimation methods, including the standard IEC 61000-4-30 method, when the analyzed signal has a form similar to that found in modern power grids. For the purposes of this study, a test signal was adopted recreating the states of the power grid, including the simultaneous occurrence of voltage fluctuations and distortions. Conclusions are presented based on conducted research. I Introduction Power quality disturbances are a common phenomenon in modern power grids. According to the current benchmark report on power quality [ 1 ] , for which the level of power quality disturbances was globally monitored, one of the most common phenomena is voltage fluctuations and distortions. This condition results in the analyzed voltage signal often being complex and nonstationary. For such a signal, it is necessary to properly determine the power quality parameters, including the fundamental frequency [ 2 , 3 , 4 ] . According to current regulatory requirements, according to the standard EN 50160, the fundamental frequency value should be between 47 and 52 Hz for 100% of the week and between 49.5 Hz and 50.5 Hz for 99.5% of the year. It is worth noting that this standard specifies that the fundamental frequency value should be determined over a 10-second interval to verify the measured value’s compliance with permissible values. Fig. 1: An example of the fundamental frequency f_{0} over time characteristic in a power network recorded using PQA, where the red line shows the fundamental frequencies f_{0} (10s) measured at a 10-second interval, and the blue and green lines show the maximum f_{0} (max) and minimum f_{0} (min) fundamental frequencies measured at successive 200 ms intervals within a 10-second window. Currently, power quality analyzers are mainly used to measure parameters that determine power quality. Class A compliance requires measuring these parameters with a specified inaccuracy in accordance with the IEC 61000-4-30 standard. For fundamental frequency measurement, this standard specifies a procedure for estimating this quantity, but also allows for the use of other methods for estimating the fundamental frequency. However, in both cases, the standard does not specify a complete measurement chain for this quantity, which can lead to problems in assessing the fundamental frequency in complex voltage signals. The fundamental frequency determined over a 10-second period exhibits little variability in a real power grid. Significant deviations in the fundamental frequency determined over a 10-second period are often noticeable during a blackout. However, if the fundamental frequency were determined for a shorter time interval, for example, 200 ms (10 fundamental voltage cycles with a rated fundamental frequency of 50 Hz), greater variability of the fundamental frequency could be observed, as shown in Fig. 1 and Fig. 2 , which present sample field measurement results using a Class A Power Quality Analyzer (PQA). This variability is related to the dynamics of load changes in the network and the response of the system automation to the resulting load changes. Analysis of the fundamental frequency variability determined for a 200-ms window is often used in power quality diagnostics when identifying the source of disturbances. Therefore, it is important that the method used for fundamental frequency estimation is characterized by small estimation errors, even for complex signal forms. Fig. 2: An example of the characteristic fundamental frequency f_{0} over time on board a passenger train recorded using PQA, where the red line shows the fundamental frequencies f_{0} (10s) measured at a 10-second interval, and the blue and green lines show the maximum fundamental frequencies f_{0} (max) and minimum f_{0} (min) measured at successive 200 ms intervals within a 10-second window. This paper presents assessment of fundamental frequency estimation errors for the method specified in the IEC standard and other estimation methods available in the literature. Numerical simulation studies were conducted using a signal recreating typical disturbances in a low-voltage power network. Section II describes the fundamental frequency estimation methods studied. Section III presents a description of the research. Section IV presents selected research results and a discussion. Section V presents the final conclusions. II Considered methods of estimation of the fundamental frequency II-A IEC 61000-4-30 Method The IEC 61000-4-30 standard specifies that the fundamental frequency should be determined according to the following relationship: \widetilde{f_{0}}=\frac{N_{T_{0}}}{\Delta t_{N_{T_{0}}}}, (1) where N_{T_{0}} is the total number of periods in the measurement window, \Delta t_{N_{T_{0}}} is the duration of the total number of periods in the measurement window. Additionally, the standard specifies that, to minimize the impact of multiple zero crossings, harmonics and interharmonics should be suppressed before each estimation. Therefore, it can be concluded that, in the basic variant, the standard specifies that the start and end times of the periods should be determined using the zero-crossing detection method. It is also worth noting that, with respect to the aforementioned filter, there is no specific filter characteristic specified for this purpose. For the purposes of the study, a 100th-order band-pass filter with finite impulse response was adopted. The bandwidth was assumed to be 46-54 Hz. II-B Autocorrelation method The autocorrelation method determines the fundamental frequency as the inverse of the fundamental period estimated by the method. In turn, the fundamental period using this method is determined as the average value of the difference in the local maxima of the autocorrelation function in the time domain, taking into account information about the sampling frequency. For a more stable operation of the method, when determining local maxima, it is assumed that the distance between local maxima cannot be less than approximately 13.3 ms. II-C Hilbert method The Hilbert method determines the fundamental frequency for a given time interval as the average value of the instantaneous frequency f_{\text{inst}}(t) in the analyzed window. The instantaneous frequency f_{\text{inst}}(t) is determined according to the relationship: f_{\text{inst}}(t)=\frac{1}{2\pi}\frac{\text{d}\phi(t)}{\text{d}t}, (2) where \phi(t) is the instantaneous phase determined as the argument of the analytical signal of the measured signal, the imaginary part of which is the Hilbert transform of the measured signal. II-D Modified ESPRIT method The ESPRIT algorithm models the sampled waveform as a superposition of complex exponentials. Specifically, given a sequence of sampled data x ( n ) of length L , the signal is approximated as follows [ 5 ] : \widehat{x}(n)=\sum_{k=1}^{M}A_{k}e^{j\psi_{k}}e^{(\alpha_{k}+j2\pi f_{k}\ )nT_{s}}+r(n), (3) where n =0,1,…, L -1, r ( n ) denotes additive white noise, and A_{k} , \psi_{k} , f_{k} , and \alpha_{k} represent the amplitude, initial phase, frequency, and damping factor of the k -th component, respectively. These parameters are unknown and must be estimated. Defining

Read the complete text