Characterization of the commercial spectrograph system for astronomical observations: PIXIS 1300BX Camera and IsoPlane 320A Spectrograph

Jiwon Jang, Changsu Choi, Ho Seong Hwang, Haeun Chung, Hyeonguk Bahk, Dongkok Kim, Jae-Woo Kim · 2026

Read Characterization of the commercial spectrograph system for astronomical observations: PIXIS 1300BX Camera and IsoPlane 320A Spectrograph by Jiwon Jang, Changsu Choi, Ho Seong Hwang, Haeun Chung, Hyeonguk Bahk, Dongkok Kim, Jae-Woo Kim (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-16371.txt.

Introduction

Jiwon Jang and coauthors test a trade scope set for sky views. Their 2026 preprint sets out the PIXIS 1300BX cam and its mate scope parts. Trade sets must be checked as a whole ere use in night work. The team runs the set through lab and sky tests. Tests span sharp grade, noise and true light counts.

A full trait map tells users what the set can and can not do. It also gives a base line for later wear checks. Trade sets at low cost serve schools and small teams well. Firm trait maps help those teams plan night work. The work is a tool note for sky users.

Catalog record

CREATORJiwon Jang, Changsu Choi, Ho Seong Hwang, Haeun Chung, Hyeonguk Bahk, Dongkok Kim, Jae-Woo Kim
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE75 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2601-16371

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Characterization of the commercial spectrograph system for astronomical observations: PIXIS 1300BX Camera and IsoPlane 320A Spectrograph Jiwon Jang, Changsu Choi, Ho Seong Hwang, Haeun Chung, Hyeonguk Bahk, Dongkok Kim, Jae-Woo Kim Abstract 0009-0003-1999-0913 0000-0001-8642-1241 0000-0003-3428-7612 0000-0002-3043-2555 0009-0002-9878-1126 0000-0003-4127-6110 0000-0002-1710-4442 1]Astronomy Program, Department of Physics and Astronomy, Seoul National University, Gwanak-gu, Seoul 08826, Republic of Korea 2]SPEX Inc., R&D Center: 28165, 215, Yeonge 1-gil 24-35, Osong-eup, Heungdeok-gu, Cheongju-si, Chungcheongbuk-do, Republic of Korea 3]SNU Astronomy Research Center, Seoul National University, Gwanak-gu, Seoul 08826, Republic of Korea 4]University of Arizona, Steward Observatory, 933 N. Cherry Ave., Tucson, AZ 85721, USA. 5]Institute for Data Innovation in Science, Seoul National University, Seoul 08826, Korea 6]Korea Astronomy and Space Science Institute, 776 Daedeok-daero, Yuseong-gu, Daejeon 34055, Republic of Korea \jkashead 1 Introduction Advances in detector technology have driven breakthroughs in astronomy. Over the past few decades, the numerous data products from large sky surveys have brought unprecedented improvements to astronomical discoveries. In particular, charge-coupled devices (CCDs) have been widely used for photometry and spectroscopy, primarily owing to their high sensitivity, high linearity, long-term stability, and low readout noise ( Janesick 2001 ; Howell 2006 , e.g.,) . Meanwhile, complementary metal-oxide-semiconductor (CMOS) image sensors have gained considerable traction in astronomical applications, benefiting from faster readout speeds, reduced power consumption, and widespread commercial availability ( Fossum 1993 ; Janesick 2007 , e.g.,) . Advances in CMOS technology—particularly in reducing readout noise and improving sensitivity—made them comparable or even superior to CCDs. Nonetheless, CCDs remain highly competitive for both photometric and spectroscopic observations of faint targets, where long exposures render readout speed less critical. Furthermore, a multi-object spectrograph (MOS) using robotic fiber positioners requires additional time for fiber alignment between successive sky fields ( Fabricant et al. 2005 ; DESI Collaboration et al. 2016 , e.g.,) . In such cases, sensitivity and stability outweigh readout speed. Although modern CMOS sensors have achieved notable improvements, they often exhibit a steeper decline in sensitivity beyond roughly 600\;\rm nm ( Alarcon et al. 2023 ; Khandelwal et al. 2024 ; Layden et al. 2025 ) , whereas CCDs maintain high quantum efficiency across a broad wavelength range. Therefore, many spectroscopic surveys still adopt CCDs for their observations ( Gunn et al. 1998 ; Bebek et al. 2017 , e.g.,) . The CCD camera (PIXIS 1300BX) and the spectrograph (IsoPlane 320A) in this study were selected as part of the preparatory work for the all-sky spectroscopic survey of nearby galaxies ( Kwon et al. 2026 , A-SPEC;) . These instruments are intended for the commissioning observations of A-SPEC. The main survey itself will be conducted using a spectrograph developed at Australian Astronomical Optics–Macquarie, which is a revised version of the TAIPAN spectrograph ( Staszak et al. 2016 ) . To select the best combination of commercially available spectrographs for our purpose, we imposed several key requirements. First, the spectral resolution needed to be comparable to the scientific requirements of A-SPEC ( R\approx 1600-2000 ), with the flexibility to adjust the resolution if necessary. This requirement is met by the IsoPlane 320A through its triple-grating turret, which allows three gratings to be installed and selected interchangeably. Second, the CCD was required to have a high quantum efficiency over the wavelength range relevant to the survey, specifically \rm QE\gtrsim 80\% across 370-870\;\rm nm . Third, the spectrograph needs to support multi-object spectroscopy with a detector large enough to capture multiple fiber-fed spectra simultaneously. The PIXIS 1300BX, with a detector size 26.8\times 26.0\rm\;mm^{2} , comfortably covers the required focal-plane size 27\times 22\rm\;mm^{2} . At the time of instrument selection in 2021, the combination of IsoPlane 320A and PIXIS 1300BX represented the optimal choice that satisfied all of these criteria within the available budget (approximately 150 million KRW). Although these instruments are used only for commissioning purposes, the performance tests and operational experience gained through this study will be directly applicable to the main A-SPEC instruments in future work. The spectrograph system is currently installed at the 1 m telescope at Seoul National University Astronomical Observatory (SAO). In this paper, we characterize the CCD camera and the spectrograph intended for A-SPEC surveys, and make our Python test code publicly available. This paper is organized as follows. In Section 2 , we summarize the basic specifications of the target instruments as in the datasheet of the manufacturer and outline the laboratory setup. In Section 3 , we describe the methodology and results of the CCD camera characterization. We also propose a novel approach for managing the shutter-less CCD intended for spectrograph applications in a laboratory environment, incorporating its effect into photometric noise analysis. Our results encompass gradient effect correction, bias level time variability, readout noise, dark current, spatial non-uniformity of thermal noise, photon transfer curve (PTC), linearity, full well capacity (FWC), quantum efficiency (QE), and charge persistence measurements. In Section 4 , we present spectrograph characterization results, including spatial separability of multi-fiber spectra and spectral resolution. In Section 5 , we validate performance with on-sky observations of the standard stars as a practical demonstration. Finally, we propose a standardized procedure for evaluating both spectrographs and cameras in future spectroscopic survey programs, and we provide all associated analysis routines as publicly available Python packages, EvalCCD and EvalSpec . 2 Instruments 2.1 CCD We test the PIXIS 1300BX Camera 1 1 1 https://www.teledynevisionsolutions.com/products/pixis/ , manufactured by Teledyne Princeton Instruments (PI). This camera features a back-illuminated design that makes the detector highly sensitive in both visible and near-infrared (NIR) wavelengths, suppressing the etalon phenomenon (i.e., interference between reflected light from the surface and reflected light from the bottom plane of the silicon substrate) in the NIR regime. It has 1340\times 1300 pixels with a pixel size of 20\;\mu\rm m . The camera includes thermoelectric cooling down to -65\;\rm^{\circ}C . The camera features low dark currents and low readout noise, typically measuring 0.01\;e^{-}\rm\;pixel^{-1}\;s^{-1} (at -60\;\rm^{\circ}C ) and 12\;e^{-}\;\rm rms (at 2\;\rm MHz readout speed), respectively. While the camera features an electronic shutter, it does not include a mechanical shutter. An external mechanical shutter is only available when the camera is mounted on the spectrograph. The characteristics provided by the manufacturer are summarized in Table 1 . Table 1: Technical information of PIXIS 1300BX Features Value CCD format 1340\times 1300 ( 26.8\times 26.0\;\rm mm^{2} ) Pixel size 20\;\mu\rm m Full well 250\;\rm{k}e^{-} (single pixel) 1000\;\rm{k}e^{-} (output node) Dark Noise 0.01\;e^{-}\rm\;pixel^{-1}\;s^{-1} (@ -60\;\rm^{\circ}C ) Readout Noise 12\;e^{-}\;\rm rms (@ 2\;\rm MHz ) A/D sampling depth 16 bit A/D sampling rate 100\;\rm kHz / 2\;\rm MHz Shutter type EM shutter (external shutter port available) Cooling <-65\;\rm^{\circ}C 2.2 Optical Test Bench To conduct the CCD characterization experiments, we set up the optical test bench depicted in Figure 1 . All bias and dark-frame measurements are carried out in a dark room, temperature-controlled room ( 16\;\rm^{\circ}C , 40-50\% RH). For illuminated tests—such as photon transfer curve, linearity, and charge persistence measurements—we require highly uniform flux on the sensor surface. To achieve this, we utilize an integrating sphere, transforming incident light into a uniform output through diffuse reflection. This approach ensures homogeneous illumination without any gradients, enhancing the reliability of our result ( Labsphere 2017 ; Nayak et al. 2001 , e.g.,) . We couple a continuum Xe

Read the complete text