Read Filtered 2D Contour-Based Reconstruction of 3D STL Models from CT-DICOM Images by K.Punnam Chandar, Y.Ravi Kumar (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-14997.txt.
Introduction
K. Punnam Chandar and Y. Ravi Kumar describe how to turn CT scans into 3D printable models. Their 2026 arXiv paper deals with medical images stored in DICOM format. Building a 3D STL model from 2D scan slices helps doctors grasp a structure's shape and any deformity.
The steps start with cleaning the CT images. Contrast is raised, noise is cut, and the images are smoothed. The cleaned scans are then split into regions by a threshold rule. From the 2D contours of those regions, the team rebuilds the full 3D model.
Catalog record
| CREATOR | K.Punnam Chandar, Y.Ravi Kumar |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 18 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2601-14997
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Filtered 2D Contour-Based Reconstruction of 3D STL Models from CT-DICOM Images K.Punnam Chandar, Y.Ravi Kumar Abstract Reconstructing a 3D Stereo-lithography (STL) Model from 2D Contours of scanned structure in Digital Imaging and Communication in Medicine (DICOM) images is crucial to understand the geometry and deformity. Computed Tomography (CT) images are processed to enhance the contrast, reduce the noise followed by smoothing. The processed CT images are segmented using thresholding technique. 2D contour data points are extracted from segmented CT images and are used to construct 3D STL Models. The 2D contour data points may contain outliers as a result of segmentation of low resolution images and the geometry of the constructed 3D structure deviate from the actual. To cope with the imperfections in segmentation process, in this work we propose to use filtered 2D contour data points to reconstruct 3D STL Model. The filtered 2D contour points of each image are delaunay triangulated and joined layer-by-layer to reconstruct the 3D STL model. The 3D STL Model reconstruction is verified on i) 2D Data points of basic shapes and ii) Region of Interest (ROI) of human pelvic bone and are presented as case studies. The 3D STL model constructed from 2D contour data points of ROI of segmented pelvic bone with and without filtering are presented. The 3D STL model reconstructed from filtered 2D data points improved the geometry of model compared to the model reconstructed without filtering 2D data points. I INTRODUCTION Computed Tomography (CT) images provide detailed information to clinicians than conventional X-rays. A fixed number of 2D slices are collected and are digitally stacked to virtually view region of interest of internal structure of human body in voxel model. The voxel models are not suitable for bio-medical applications owing to their low resolution and inconvenient modification [ 32 ] . 3D medical modeling procedure usually aims to convert the original voxel model into another kind of 3D solid model suitable for bio-medical applications. Medical images in 3D solid model allows doctors for easier identification of abnormality/deformity in internal structure [ 18 , 6 , 5 ] . All reconstructed 3D solid models can be converted to rapid prototyping (RP) models to process them in two phases: virtual(modeling and simulating) [ 1 , 30 , 13 , 17 ] and physical (fabrication) [ 21 , 29 , 12 , 16 ] . To aid in virtual phase, there are three methods that can be applied to reconstruct a 3D solid model for bio-medical applications: polygonal model, parametric surface model and third 2D contour detection method. Polygonal Model is via voxel to stack and construct the model by using the marching-cube algorithm [ 10 , 20 ] . Parametric surface method involves a swept from the contours of each layer. The reconstructed surface can be then lofted from these contours [ 4 , 7 , 15 , 24 ] . 2D contour detection method, each slice of CT image is separately processed to extract the pile of contours and the 2D contour points are used to construct the delaunay triangulation and added with successive layers mesh by parallel polygons to form 3D model [ 29 , 11 , 3 , 23 ] . Each of these methods has certain limitations/disadvantages. With the first method, the shape modification is usually tricky and time consuming, which makes it unsuitable for RP applications [ 25 , 9 ] . The parametric surface method requires drawing of curve model in CAD and is extremely complicated. Since the spline must first be constructed before modeling can take place [ 8 ] . The 2D contour detection method suffers from drawbacks in contour detection for each CT slice and file errors in the construction and use of delaunay triangulation [ 26 , 31 , 14 ] . The present work, we propose an enhanced process for converting a CT medical images to a 3D delanunay triangulation mesh model for easing the modeling and simulation. The process of reconstructing the medical 3D mesh model can be achieved in two phases, viz., i) medical image processing and segmentation and ii) 3D reconstruction of STL mesh. Medical image processing is achieved through traditional work flow which serves to provide image enhancement followed by image segmentation. The 2D Contour data points are extracted from segmented images of each slice and are subjected to filtering operation to reduce outliers. The filtered 2D Contour data points are sorted out and delaunay triangulation is performed and adjacent layers are connected layer-by layer using extra polygon layer to reconstruct 3D STL model. II CT Image Processing The CT scan images are to be processed before extracting the contour of the internal structure in each slice. First, enhancement is performed followed by filtering and then smoothing before proceeding for segmentation. Flow chart of the CT images to 3D STL Model reconstruction is shown in Figure. 1 Fig. 1: Flow Chart of CT Images to 3D STL Model II-A Traditional Image Processing CT images assist the clinical practitioners to assesses the internal structure for deformity when met with serious injuries. CT images captures the intensity variations of different internal body parts like bones, muscles, fat, organs and blood vessels relative to the water in Hounsfield Unit [ 19 ] . The HU are mapped linearly to the gray scale range [0, 255]. CT Scanning captures human body in incremental scanning and provides up to 350 slices depending on the thickness of the slice or resolution of the CT scanning machine. The practicing clinicians needs to analyze each slice manually to precisely locate the deformity or injury in the internal structure. Manually analyzing slice-by-slice is a tedious task and the 3D structure need to be constructed in his imagination based on his learning and experience. Most important internal organ that will be assessed in all these CT slices is bone. Segmenting the bone in all these slices and reconstructing the 3D Structure will assist the clinicians in saving time and enough room for other medical procedures. Sample CT scan images [ 22 ] of pelvic bone from slice 80 to 84 with region of interest Pelvic bone femoral body is shown in Figure 2 . Fig. 2: CT Images Slices 80-84 with Region of Interest To process the CT scan images to reconstruct 3D Model of internal bone structure, the images need to be processed in different phases viz, Traditional Image Processing (TIP) phase, Segmentation phase, Contour extraction and filtering phase and finally layer-by- layer reconstruction of 3D STL Medical Model of the region of interest of the internal structure. Complex internal bone structure, speckle noise captured during scanning and intensity inhomogeneities need to be processed before performing the task of segmentation. The TIP Phase shown in Figure 1 ,aims to handle these challenges before proceeding for segmentation phase [ 28 , 2 ] . In TIP phase, first the CT image slice is enhanced using power-law transformation given in equation 1 , the variable s depends on c , r , and \gamma . s=c\cdot r^{\gamma} (1) In equation 1 , the input r is CT image intensity value in the range [0, 255], where intensity 0 refers to dark and 255 white. To improve the