Validation of the COSINE-100U NaI(Tl) Encapsulation for Low-Temperature Operation in Liquid Scintillator

G. H. Yu · 2026

Read Validation of the COSINE-100U NaI(Tl) Encapsulation for Low-Temperature Operation in Liquid Scintillator by G. H. Yu (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-12819.txt.

Introduction

G. H. Yu validates a detector encapsulation for a dark matter search upgrade called COSINE-100U. The upgrade boosts sensitivity by immersing the detector array in liquid scintillator. The array must run cold, at minus thirty degrees Celsius. Crystals of sodium iodide with thallium serve as the sensing material.

Yu built a module with the new encapsulation design. A dedicated long term stability study checked it under the planned conditions. Encapsulation must keep the crystals dry and intact while cold and submerged. A failed seal could ruin a rare event search that runs for years. Validation of this kind is the quiet groundwork of dark matter science.

Catalog record

CREATORG. H. Yu
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE20 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2601-12819

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Validation of the COSINE-100U NaI(Tl) Encapsulation for Low-Temperature Operation in Liquid Scintillator G. H. Yu Abstract The COSINE-100U (upgrade) will enhance the sensitivity of the COSINE-100 dark matter search by operating the detector array immersed in liquid scintillator (LS) at − 30 ∘ ​ C -30^{\circ}\text{C} . To validate the detector design for these conditions, we constructed a module using the COSINE-100U encapsulation and performed a dedicated long-term stability study. The module was first monitored at room temperature for ~110 days in air, followed by a one-week immersion in LAB-based LS to verify initial compatibility. Upon confirming stable optical performance, the temperature was lowered to − 33 ∘ ​ C -33^{\circ}\text{C} . During approximately 150 days of continuous operation at low temperature, we observed no degradation in performance. These results demonstrate the chemical and mechanical robustness of the encapsulation, confirming its suitability for the COSINE-100U physics run. 1 Introduction Astrophysical and cosmological observations consistently point to the presence of non-luminous matter that dominates the mass density of the Universe [ 13 , 14 ] . The nature of this dark matter remains unknown, and several complementary strategies are pursued in parallel: direct searches with low-background underground detectors, indirect probes of annihilation or decay products, and collider-based searches for dark-sector states at electron–positron and hadron colliders [ 10 , 21 , 1 , 2 , 29 , 30 ] . Although no concrete evidence of dark matter interactions has yet been observed, there remains the long-standing debate surrounding DAMA/LIBRA, which reported a clear annual-modulation signal in a NaI(Tl) crystal array compatible with dark matter [ 11 , 12 ] . The COSINE-100 experiment [ 3 ] was designed to test DAMA/LIBRA using the same target material and comparable analysis techniques. The experiment deployed eight low-background NaI(Tl) crystals, with a total mass of 106 kg, inside a liquid-scintillator veto [ 6 ] surrounded by copper, lead, and plastic scintillator muon panels [ 32 ] at the Yangyang underground laboratory in Korea. COSINE-100 has carried out both model-independent searches for a dark-matter–induced annual modulation [ 5 , 7 , 17 , 16 ] and model-dependent spectral analyses [ 8 , 9 , 36 ] , finding no signals compatible with DAMA/LIBRA in NaI(Tl). Beyond testing the DAMA/LIBRA claim, NaI(Tl) offers unique advantages due to the unpaired protons in both sodium and iodine isotopes. Given the relatively low mass number of sodium, NaI(Tl) has competitive sensitivity to Spin-Dependent WIMP-proton interactions in the low-mass dark matter region, as demonstrated in recent COSINE-100 results [ 36 ] . To further explore this parameter space, the COSINE-100 upgrade (COSINE-100U) [ 23 ] is being commissioned at Yemilab [ 28 , 22 ] , a new underground laboratory in Korea. This upgrade aims to enhance sensitivity to low-mass dark matter by increasing the light collection efficiency A key feature of the upgrade is a novel crystal encapsulation technique [ 20 ] . Because NaI(Tl) is hygroscopic, crystals are typically encased in copper with a quartz optical window. To maximize light yield, we developed an encapsulation method that couples photomultiplier tubes (PMTs) directly to the crystal, eliminating the quartz window. This design enhances light collection efficiency by approximately 50% [ 20 , 19 ] . The long-term stability of this design in liquid scintillator (LS) at room temperature (RT) was previously demonstrated by the NEON experiment [ 18 ] over two years of operation [ 19 ] . While COSINE-100U has begun initial physics operations at Yemilab [ 28 , 22 ] with crystals at RT, the ultimate goal is to operate the array at a low temperature (LT) of approximately -30^{\circ}\text{C} [ 23 ] . This lower temperature offers the dual advantages of increased intrinsic light yield and improved pulse shape discrimination [ 27 ] . However, operating hygroscopic NaI(Tl) crystals immersed in LS at cryogenic temperatures introduces significant engineering challenges, specifically regarding the chemical compatibility of the encapsulation seals and the thermo-mechanical stress during cooling. This work serves as the critical validation of the encapsulation design prior to the cryogenic deployment of the full COSINE-100U array. We present a dedicated long-term stability measurement of a NaI(Tl) crystal encapsulated using the COSINE-100U method. The detector was operated first at RT without LS, and then fully immersed in LS at -33^{\circ}\text{C} . We monitored the light yield and energy resolution of the 59.54 keV \gamma -ray line from an {}^{241}\text{Am} source throughout the study. We find that the optical quality of the NaI(Tl) crystal remained unchanged during an operation period of approximately one year, which included roughly 110 days at RT and 150 days at -33^{\circ}\text{C} . These results validate the robustness of the COSINE-100U encapsulation for operation in LS at approximately -30^{\circ}\text{C} . 2 Experimental setup The prototype detector utilizes the NaI-037 NaI(Tl) crystal [ 24 ] , grown at the Center for Underground Physics (IBS, Korea) using the purified powder described in Refs [ 35 , 34 ] . The crystal is cylindrical, with a diameter of 70 mm and a height of 51 mm, and has a mass of approximately 0.70 kg after surface polishing. We followed the encapsulation procedure developed for COSINE-100U [ 23 ] , with one modification: the crystal edges were not machined, as the 70 mm diameter already matches the active area of the 3-inch PMTs. Prior to assembly, all encapsulation materials were cleaned in dilute Citranox via sonication, baked in an oven, and transferred to a glovebox. The glovebox atmosphere was maintained with a humidity (H 2 O) level of \mathcal{O}(10) ppm using a molecular-sieve trap. During the assembly, the glovebox was flushed with N 2 gas at a rate of 5 L/min to minimize {}^{222}\text{Rn} contamination from component emanation. The crystal end faces were mirror-polished using a polishing pad with SiO 2 abrasives, while the barrel surface was gently wiped with anhydrous ethanol. For the optical interface, 2 mm thick silicone pads (Eljen EJ-560) were coupled to the top and bottom faces of the crystal. Two high-quantum-efficiency 3-inch PMTs (Hamamatsu R12669SEL) were attached to these pads to maximize light collection. The curved side of the crystal was wrapped in several layers of soft, Polytetrafluoroethylene (PTFE)-based Tetratex, which serves as a diffuse reflector to contain scintillation light. A PTFE holder secures the mechanical coupling between the crystal and PMTs, ensuring uniform optical contact. The entire assembly was centered in a copper support and enclosed in a copper housing matching the COSINE-100U design [ 23 ] . Crucially, the housing is sealed using Viton O-rings selected for their chemical compatibility with LS and mechanical resilience at -30^{\circ}\text{C} . The overall assembly procedure is illustrated in Fig. 1. Figure 1 : Assembly sequence of the NaI-037 NaI(Tl) detector: (a) the polished crystal after surface treatment; (b) attachment of the silicone optical pad to the PMT window; (c) the crystal coupled to two 3-inch Hamamatsu R12669SEL PMTs; (d) wrapping of the crystal and PMT assembly with PTFE-based Tetratex reflector; (e) installation of the PTFE holder to secure the crystal and PMTs; and (f) insertion of the assembled detector into the upgraded COSINE-100U copper housing. The stability of this encapsulation design in LS at RT was previously demonstrated by the NEON experiment over a two-year

Read the complete text