Direct in-chamber radon-220 (thoron) emanation measurements for rare-event physics experiments

and N.J.C. Spooner · 2026

Read Direct in-chamber radon-220 (thoron) emanation measurements for rare-event physics experiments by and N.J.C. Spooner (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-12622.txt.

Introduction

N. J. C. Spooner and colleagues report direct measurements of thoron gas coming off detector materials. Thoron is radon 220, a radioactive gas that seeps from many solids. Radon is a major background in rare event physics, where tiny signals hide easily. Measuring how much gas a material emits is a key way to control that background.

Most past emanation work targeted radon 222, the dominant isotope for these backgrounds. Thoron has been measured far less, despite its own risks. The team measure thoron emanation inside the chamber itself, a direct approach. Rare event searches, like dark matter hunts, need such care at every step. A missed background can fake a discovery, so these checks matter.

Catalog record

CREATORand N.J.C. Spooner
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE27 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2601-12622

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Direct in-chamber radon-220 (thoron) emanation measurements for rare-event physics experiments and N.J.C. Spooner Abstract Measuring radon emanation from detector materials is a key method for controlling radon, a significant background in rare-event physics experiments. Methods for measuring radon emanation are well-established but have predominantly focused on the Rn 222 {}^{222}\mathrm{Rn} isotope, the dominant radon isotope for these backgrounds. However, measurements of Rn 220 {}^{220}\mathrm{Rn} (thoron), the second most abundant radon isotope, remain relatively unexplored. Rn 220 {}^{220}\mathrm{Rn} emanation measurements are challenging because the Rn 220 {}^{220}\mathrm{Rn} must be transferred from the emanation chamber to the active detector within its short 55 ​ s 55~\mathrm{s} half-life. In this study, a direct in-chamber approach for measuring Rn 220 {}^{220}\mathrm{Rn} emanation is presented in which the sample is placed directly within the active detector chamber, thereby minimising losses during transfer. The method was demonstrated with a DURRIDGE RAD8 electrostatic radon detector, which measured Rn 220 {}^{220}\mathrm{Rn} emanation from low-activity thoriated rods with an activity of 76 ± 20 ​ mBq 76\pm 20~\text{mBq} . Compared with a conventional flowthrough Rn 220 {}^{220}\mathrm{Rn} emanation setup, the in-chamber method increased sensitivity by a factor of 3. Using helium as the carrier gas provided a further sensitivity increase, giving an overall sensitivity gain of ∼ \sim 5. These results indicate that in-chamber Rn 220 {}^{220}\mathrm{Rn} emanation measurements provide an effective tool for low-background experiments and have the potential to accelerate radon studies by exploiting the shorter half-life of Rn 220 {}^{220}\mathrm{Rn} . 1 Introduction Radon contamination is a well-known source of unwanted background and remains a significant challenge for many rare-event physics experiments, such as dark matter and neutrinoless double beta decay searches [ 1 , 6 , 3 , 8 ] . The most significant isotope for radon-induced background is {}^{222}\mathrm{Rn} . The second most significant radon isotope, {}^{220}\mathrm{Rn} (also known as thoron), has historically received less attention because of its half-life of 55.6 seconds which is short when compared with 3.8 days for {}^{222}\mathrm{Rn} . This short half-life limits the diffusion length of {}^{220}\mathrm{Rn} , suppressing the amount that can emanate from bulk materials into the active detector volume. However, {}^{220}\mathrm{Rn} originating at or near detector surfaces can make a measurable contribution, and a {}^{220}\mathrm{Rn} background component has been reported in several dark matter experiments [ 4 , 12 , 2 , 5 ] . One of the leading radon mitigation strategy is to perform extensive screening of detector materials by measuring their intrinsic radon emanation. Techniques for {}^{222}\mathrm{Rn} emanation measurements are well-developed and achieve very high sensitivities using a range of established methods [ 19 , 22 , 7 , 23 ] . These approaches typically rely on accumulating {}^{222}\mathrm{Rn} from an emanation chamber over long periods and then transferring the gas to a detector chamber. This procedure is poorly suited to {}^{220}\mathrm{Rn} because of its short half-life. Although {}^{220}\mathrm{Rn} monitoring instruments exist and are widely used in industrial applications, they are designed for comparatively high {}^{220}\mathrm{Rn} levels [ 14 ] , and their sensitivity is insufficient for the low activity levels required in rare-event physics. It is therefore important to develop dedicated {}^{220}\mathrm{Rn} emanation techniques for low-background experiments. Beyond its role in quantifying backgrounds, a dedicated {}^{220}\mathrm{Rn} emanation facility provides a powerful diagnostic tool for material studies. In many rare-event detectors, particularly those operated at cryogenic temperatures, the dominant {}^{222}\mathrm{Rn} contribution comes from recoil-induced emanation from surfaces and near-surface regions of detector components, rather than from diffusion out of bulk materials [ 16 ] . In this context, {}^{220}\mathrm{Rn} can serve as a rapid first-pass proxy for {}^{222}\mathrm{Rn} surface behaviour. This makes {}^{220}\mathrm{Rn} emanation measurements a useful tool for supporting and accelerating studies of surface treatments and coatings designed to suppress radon emanation. In this paper, the mechanisms for radon emanation measurements, with a focus on {}^{220}\mathrm{Rn} and their limitations, are discussed in Section 2 . To provide a baseline, the conventional {}^{220}\mathrm{Rn} emanation method, its experimental setup, and subsequent analysis are described in Section 3 . The improved in-chamber method, together with its experimental setup and analysis, is presented in Section 4 . A further enhancement using helium as the carrier gas is introduced in Section 5 . Finally, practical applications for low-background studies are discussed in Section 6 . 2 Measurement of 220 Rn emanation Radon emanation measurements typically proceed in three stages: an emanation period in a sealed chamber containing the sample of interest, transfer of the accumulated radon into a detection chamber, and subsequent measurement with a radon detector. The emanation period is required to allow radon to be produced from its parent radionuclides, escape from the sample, and accumulate in the chamber. The emanation period is usually chosen so that the activity in the chamber is representative of the secular equilibrium value for the isotope of interest. In practice, this is achieved by waiting for several half-lives of the radon isotope. After about five to seven half-lives the activity has risen to within a few per cent (approximately 97–99%) of its asymptotic value. For {}^{220}\mathrm{Rn} (thoron), which has a half-life of 55 seconds, this corresponds to about 5–10 minutes of emanation with {}^{224}\mathrm{Ra} as the parent. In contrast, {}^{222}\mathrm{Rn} , with a half-life of 3.8 days, typically requires 25–30 days to approach secular equilibrium with {}^{226}\mathrm{Ra} . Typically, shorter emanation times are used and the accounted for in the analysis [ 10 , 15 ] . Once the emanation period is complete, the gas is transferred from the emanation chamber to the detection chamber. Many approaches exist for transferring radon between chambers, including complex setups based on physisorption on charcoal traps or liquefaction of radon [ 20 , 22 ] . While these methods work well for {}^{222}\mathrm{Rn} , they are poorly suited to {}^{220}\mathrm{Rn} because the additional transfer steps introduce delays. As a result, practical {}^{220}\mathrm{Rn} emanation measurements tend to rely on simple gas-flow transfer with short lines between the emanation and detector volumes. Once the radon is inside the detection chamber, most emanation setups use electrostatic collection, which offers good energy resolution and can be adapted to different carrier gases. Figure 1 shows a schematic of a typical electrostatic detector chamber. A high negative voltage is applied to the chamber walls, while the passivated implanted planar silicon (PIPS) detector is held at ground potential, generating an electric field within the active volume. {}^{220}\mathrm{Rn} atoms that have been successfully transferred into the detector (red in Figure 1 ) decay to short-lived, positively charged progeny (green), which drift along the field lines to the PIPS active alpha detector surface before decaying. Their subsequent alpha decays are measured and converted to a {}^{220}\mathrm{Rn} activity. Figure 2 shows the {}^{220}\mathrm{Rn} decay chain, where information inside the circles indicate the nuclides and their half-lives, and the arrows indicates decay modes and alpha energies. For electrostatic {}^{220}\mathrm{Rn} measurements, the primary collected progeny is {}^{216}\mathrm{Po} , which emits a 6.9 MeV alpha particle. Subsequent alpha decays from {}^{212}\mathrm{Bi} (6.2 MeV, with an \sim 36\% alpha-branching ratio) and {}^{212}\mathrm{Po} (8.9 MeV) also appear in the spectrum. In practice, the activity is usually determined from the {}^{216}\mathrm{Po} peak only, which responds almost immediately, whereas the {}^{212}\mathrm{Bi} and {}^{212}\mathrm{Po} peaks require of order 12 hours to

Read the complete text