The BigBite Calorimeter for the Super Bigbite Spectrometer Program at Jefferson Lab Journal: NIM A
P. Datta, K.T. Evans, J. Bane, H. Bhatt, B. Devkota, E. Fuchey, T. Hague, D.W. Higinbotham, A. Hoebel, M.K. Jones, A. Karki, M. Kubantsev, S. Li, M. Nycz, R. Pomatsalyuk, A.J.R. Puckett, I. Rachek, S. Riordan, B. Sawatzky, S.A. Seeds, A. Shahinyan, Y. Shestakov, A.S. Tadepalli, †V. Verebryusov, H. V · 2026
Read The BigBite Calorimeter for the Super Bigbite Spectrometer Program at Jefferson Lab Journal: NIM A by P. Datta, K.T. Evans, J. Bane, H. Bhatt, B. Devkota, E. Fuchey, T. Hague, D.W. Higinbotham, A. Hoebel, M.K. Jones, A. Karki, M. Kubantsev, S. Li, M. Nycz, R. Pomatsalyuk, A.J.R. Puckett, I. Rachek, S. Riordan, B. Sawatzky, S.A. Seeds, A. Shahinyan, Y. Shestakov, A.S. Tadepalli, †V. Verebryusov, H. V (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-10799.txt.
Introduction
P. Datta and a large collaboration report the BigBite Calorimeter, an instrument built for Jefferson Lab. The calorimeter is made of lead glass and measures electron energies. It forms the electron arm of the BigBite Spectrometer. That spectrometer served the Super Bigbite program in Hall A, which measured neutron electromagnetic form factors with high precision.
The paper covers the design, construction, installation, and performance of the device. Form factors describe how charge and magnetism spread inside the neutron. Precise values test our picture of quarks inside matter. Instrument papers like this one are the record that lets later teams trust, reuse, and improve the hardware behind the physics.
Catalog record
| CREATOR | P. Datta, K.T. Evans, J. Bane, H. Bhatt, B. Devkota, E. Fuchey, T. Hague, D.W. Higinbotham, A. Hoebel, M.K. Jones, A. Karki, M. Kubantsev, S. Li, M. Nycz, R. Pomatsalyuk, A.J.R. Puckett, I. Rachek, S. Riordan, B. Sawatzky, S.A. Seeds, A. Shahinyan, Y. Shestakov, A.S. Tadepalli, †V. Verebryusov, H. V |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 75 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2601-10799
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
The BigBite Calorimeter for the Super Bigbite Spectrometer Program at Jefferson Lab Journal: NIM A P. Datta, K.T. Evans, J. Bane, H. Bhatt, B. Devkota, E. Fuchey, T. Hague, D.W. Higinbotham, A. Hoebel, M.K. Jones, A. Karki, M. Kubantsev, S. Li, M. Nycz, R. Pomatsalyuk, A.J.R. Puckett, I. Rachek, S. Riordan, B. Sawatzky, S.A. Seeds, A. Shahinyan, Y. Shestakov, A.S. Tadepalli, †V. Verebryusov, H. Voskanyan, B. Wojtsekhowski, A. Yoon Abstract We report features of the design, construction, installation, and performance of the BigBite Calorimeter (BBCal), a lead-glass electromagnetic calorimeter constructed as part of the BigBite Spectrometer (BBS), which served as the electron arm for the Super Bigbite Spectrometer (SBS) program of high-precision neutron electromagnetic form factor measurements in Hall A at Jefferson Lab. As a total-absorption calorimeter, BBCal provided the primary electron trigger for BBS, detecting (quasi-) elastically scattered electrons in the 1-4 GeV energy range with an energy resolution of approximately 6.2 % 6.2\% , position resolution of 1.2 cm, and timing resolution of 0.5 ns. 1 Introduction The first version of the BigBite calorimeter (BBCal) was constructed during the 6 GeV era of Jefferson Lab experiments aimed at exploring nucleon structure in exclusive and semi-inclusive processes in the intermediate Q^{2} range [ 1 , 2 ] . Due to the drop in cross section, the next generation of experiments that wished to extend these studies to larger Q^{2} values required detectors which could handle higher luminosities, requiring higher data acquisition and trigger rate capabilities, and better, radiation-hard calorimeter modules. The advent of high-luminosity polarized targets, fast tracking detectors, and high-intensity electron beams opened doors to a new series of high-precision measurements. The 12 GeV upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) [ 3 ] has enabled a new generation of high-precision measurements at Jefferson Lab (JLab). Taking advantage of the upgrade to the beam energy and detector capabilities, the Super Bigbite Spectrometer (SBS) collaboration conducted a series of experiments in JLab’s experimental Hall A between fall 2021 and summer 2025 to determine nucleon electromagnetic form factors with unprecedented precision and resolution. The objectives of the experiments that used the calorimeter described in this paper are summarized below: 1. E12-09-019 (SBS-GMn, Oct 2021–Feb 2022) — First SBS experiment, extending high-precision measurements of the neutron magnetic form factor G_{M}^{n} over Q^{2}=3 -13.6 (GeV/ c ) 2 using the ratio method [ 4 ] . 2. E12-20-010 (SBS-nTPE, Jan 2022–Feb 2022) — Ran in series with SBS-GMn to perform the first Rosenbluth separation of the neutron form factors at high Q^{2} ( \sim 4.5 (GeV/ c ) 2 ) [ 5 ] . 3. E12-09-016 (GEn-II, Oct 2022–Oct 2023) — Extended precision measurements of the neutron electric form factor G_{E}^{n} over Q^{2}=3 –10 (GeV/ c ) 2 via beam–target double spin asymmetry technique utilizing a state-of-the-art polarized 3 He target [ 6 , 7 ] . 4. E12-17-004 (GEn-RP, Apr–May 2024) — Performed a G_{E}^{n} measurement via the recoil polarization technique at high Q^{2} ( \sim 4.5 (GeV/ c ) 2 ). Comparison with E12-20-010 and E12-09-016 results will provide critical tests of the one-photon exchange (OPE) approximation in elastic en scattering [ 8 ] . 5. E12-20-008 ( K_{LL} , May 2024) — Performed a measurement of polarization transfer in charged pion photoproduction in the wide angle regime. Data from this experiment will provide a critical test of the applicability of the handbag mechanism [ 9 ] . All experiments listed above employed a two-arm coincidence setup. The hadron arm consisted of the Super Bigbite Spectrometer (SBS), while the BigBite Spectrometer (BBS) was used as the electron arm. In the SBS, scattered nucleons were momentum-analyzed by the SBS dipole magnet and detected in a highly segmented hadron calorimeter (HCal) with comparable and high efficiencies for protons and neutrons. The electron arm used the BigBite dipole magnet to bend scattered charged particles into or out of the acceptance depending on their charge and momentum. Precise tracking in the BBS was achieved with five layers of Gas Electron Multiplier (GEM) detectors, and energy measurements were made in BBCal. Additional BBS subsystems included the Gas Ring Imaging Cherenkov (GRINCH) detector for particle identification and a timing hodoscope (TH) for time-of-flight measurements. The BBS layout is shown in Fig. 1 . BBCal—the focus of this work—was designed, constructed, installed, commissioned, and calibrated for the BBS and demonstrated reliable performance throughout the SBS program. Figure 1 : Side view CAD drawing of the BBS detector stack installed in experimental Hall A. Scattered electrons travel through the detector stack from left to right in the drawing. Here, BB Magnet is the BigBite magnet, GEMs are the Gas Electron Multiplier detectors, GRINCH is the Gas Ring Imaging CHerenkov detector, PS is preshower, TH is Timing Hodoscope and SH represents the shower detector. 2 Design The BigBite calorimeter (BBCal) is a lead-glass electromagnetic calorimeter consisting of two parts: the preshower (PS) and shower (SH) layers. Together these layers provide a measurement of the total energy of the scattered electrons. The main purposes of BBCal for each experiment are the following: 1. Act as the main experiment trigger with good time resolution, 2. Measure the total energy of electrons scattered from the target, 3. Identify and differentiate incoming pions and electrons, 4. Define a region-of-interest for fast and efficient track-finding in the GEM system. 2.1 Preshower Detector The PS layer of BBCal was updated from its “old" design used during JLab’s 6\, GeV era to include new lead-glass (LG) blocks (refurbished from the HERMES experiment [ 10 ] ) for better radiation hardness as well as to implement better magnetic field shielding in the form of mu-metal plates between each row of blocks and 0.25-inch thick soft iron plates in front of and behind the PS layer. The updated PS detector was constructed in the fall of 2020 at JLab and consists of 52 F101 LG blocks [ 11 ] , each with dimensions of 29.5\times 9\times 9\,\text{cm}^{3} . Tab. 1 provides details on the properties of these blocks. Table 1 : Chemical composition and important properties of both types of LG blocks used in BBCal. LG Properties F101 (PS) TF1 (SH) Chemical Comp. Weight (%) \text{Pb}{\vphantom{\text{X}}}_{\smash[t]{\text{3}}}\text{O}{\vphantom{\text{X}}}_{\smash[t]{\text{4}}} 51.23 0.0 PbO 0.0 51.2 \text{SiO}{\vphantom{\text{X}}}_{\smash[t]{\text{2}}} 41.53 41.3 \text{K}{\vphantom{\text{X}}}_{\smash[t]{\text{2}}}\text{O} 7.0 7.0 \text{As}{\vphantom{\text{X}}}_{\smash[t]{\text{2}}}\text{O}{\vphantom{\text{X}}}_{\smash[t]{\text{3}}} 0.0 0.5 Ce 0.2 0.0 Density 3.86\text{\,}\mathrm{g}\mathrm{/}\mathrm{c}\mathrm{m}^{3} 3.86\text{\,}\mathrm{g}\mathrm{/}\mathrm{c}\mathrm{m}^{3} Refractive Index 1.65\text{\,} 1.65\text{\,} Radiation Length 2.78\text{\,}\mathrm{c}\mathrm{m} 2.50\text{\,}\mathrm{c}\mathrm{m} Molière Radius 3.28\text{\,}\mathrm{c}\mathrm{m} 3.50\text{\,}\mathrm{c}\mathrm{m} Critical Energy 17.97\text{\,}\mathrm{M}\mathrm{e}\mathrm{V} 15.00\text{\,}\mathrm{M}\mathrm{e}\mathrm{V} Each LG block is attached to a Philips XP3461/PA photomultiplier tube (PMT) [ 12 ] which reads out the Cherenkov radiation emitted by relativistic charged particles and secondary e^{+}/e^{-} pairs produced in electromagnetic cascades. This combination of LG block and PMT serves as the basic unit of the PS layer. The LG blocks are arranged in 26 rows of two columns oriented perpendicular to the spectrometer axis, with the PMTs connected on the outer edge of each column. The sides of the the LG blocks on the inner edge of the columns were painted with EJ-510 reflective paint to reflect light back towards the PMT. As shown in Fig. 2 , the PMTs attached to column 0 (1) blocks are on the right (left) side of the PS, when looking downstream. Figure 2 :