Adaptive algorithm for microsensor in sustainable environmental monitoring

Nursultan Daupayev, Christian Engel, Ricky Bendyk, Prof. Dr.-Ing. Sören Hirsch · 2026

Read Adaptive algorithm for microsensor in sustainable environmental monitoring by Nursultan Daupayev, Christian Engel, Ricky Bendyk, Prof. Dr.-Ing. Sören Hirsch (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-10780.txt.

Introduction

Nursultan Daupayev, Christian Engel, Ricky Bendyk, and Sören Hirsch design an adaptive algorithm for environmental microsensors. Steady sensing matters for jobs like anomaly detection in building structures. But collecting data at a fixed rate wastes energy and piles up redundant readings. Deleting data to save space costs quality instead.

Their algorithm adapts how the sensor samples, so it gathers more when conditions change and less when they are flat. Smarter timing cuts energy use and storage load at the source. The work targets long-lived sensor networks that must run for years on small batteries. It shows how a little on-device judgment can stretch both power and data value.

Catalog record

CREATORNursultan Daupayev, Christian Engel, Ricky Bendyk, Prof. Dr.-Ing. Sören Hirsch
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE3 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2601-10780

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Adaptive algorithm for microsensor in sustainable environmental monitoring
Nursultan Daupayev, Christian Engel, Ricky Bendyk, Prof. Dr.-Ing. Sören Hirsch

Abstract




Introduction

Continuous collection of environmental data in sensors plays an important role for example for anomaly detection in building structures [1]. However, regular data collection results in high energy consumption and data redundancy, where it is necessary to either optimize data in the hardware storage or delete them, which leads to a loss of data quality [2].

Description of the method

Within the scope of applying the algorithm, we collected different parameters including carbon dioxide (
CO_{2}
), humidity (
H
) and temperature (
T
) from a micro multivariate sensor, shown in Fig. 1, installed on the surface of the wall inside the building’s room.

Fig. 1:
Multivariate Microsensor

Initially, the algorithm analyses the data behaviour and it can be represented as a time series graph for
CO_{2}
,
T
,
H
(Fig. 2) and simulation (Fig. 3) for
CO_{2}
based on 24-hour measurements with an interval of 15 minutes. In this study, we focus only on the
CO_{2}
, since the application of the method on all parameters is similar.

Fig. 2:
Microsensor Measurements

Fig. 3:
CO_{2}
Modeling

Following this, the developed algorithm is aimed at reducing the number of measurements by finding important peaks and excluding insignificant measurement points. To achieve this, by applying Fast Fourier Transform (FFT), algorithm transforms the data from the time domain to the frequency domain, which made it possible to identify the periodic characteristics of the sensor signals:

X[k]=\sum_{n=0}^{N-1}x[n]e^{-j\frac{2\pi}{N}kn},\quad k=0,1,\ldots,N-1.

(1)

Then, it determines the optimal number of harmonics to achieve a reduction in sensor measurement, where the optimal number of harmonics is selected. In this case, there are 26 optimal harmonics:

A[k]=|X[k]|=\sqrt{(\operatorname{Re}\{X[k]\})^{2}+(\operatorname{Im}\{X[k]\})^{2}}

(2)

After selecting the optimal harmonics, an algorithm uses an inverse fast Fourier transform (IFFT) to reconstruct the signal (Fig 4.). It is expected to be close to the original data, showing minor deviations from them:

x[n]=\frac{1}{N}\sum_{k=0}^{N-1}X[k]e^{j\frac{2\pi}{N}kn}

(3)

Fig. 4:
Reconstructed
CO_{2}
Signal

In addition, we are also aim to save energy by preserving at least 50% of the total signal energy (in current data measurements), while minimizing the amount of data by eliminating unimportant harmonics and saving the main signal trends:

\sum_{k=0}^{K_{\text{opt }}}|X[k]|^{2}\geq 0.5\sum_{k=0}^{N-1}|X[k]|^{2}

(4)

Results

As a result, the necessary points for sensor activation were obtained by applying the DFT and HA, that allowed to reduce the number of measurements, while saving important frequency characteristics of the signal (Fig.5).

Fig. 5:
Microsensor activation time for

Read the complete text