Neural-network-based high-speed and high-definition full-field dynamic optical coherence tomography Journal: opticajournal Publication type: Research Article
Suzuyo Komeda, 1 Nobuhisa Tateno, 1 Yusong Liu, 1 Rion Morishita, 1 Xibo Wang, 1 Ibrahim Abd El-Sadek, 1,2 Atsuko Furukawa, 3 Satoshi Matsusaka, 3 Shuichi Makita, 1 and Yoshiaki Yasuno 1,* · 2026
Read Neural-network-based high-speed and high-definition full-field dynamic optical coherence tomography Journal: opticajournal Publication type: Research Article by Suzuyo Komeda, 1 Nobuhisa Tateno, 1 Yusong Liu, 1 Rion Morishita, 1 Xibo Wang, 1 Ibrahim Abd El-Sadek, 1,2 Atsuko Furukawa, 3 Satoshi Matsusaka, 3 Shuichi Makita, 1 and Yoshiaki Yasuno 1,* (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-10327.txt.
Introduction
Suzuyo Komeda and co authors speed up a deep scan of live tissue. The scan is optical coherence tomography, or OCT. It maps tissue by light bounce in depth. A dynamic form tracks how cells move. The rig used here sweeps a full field at once.
Full field scans yield sharp maps but vast data. That bulk makes streams slow and holds back fast work. The team use a neural net to cut that load. It forms sharp dynamic maps at high speed. The aim is high throughput scans that clinics and labs can run live.
Catalog record
| CREATOR | Suzuyo Komeda, 1 Nobuhisa Tateno, 1 Yusong Liu, 1 Rion Morishita, 1 Xibo Wang, 1 Ibrahim Abd El-Sadek, 1,2 Atsuko Furukawa, 3 Satoshi Matsusaka, 3 Shuichi Makita, 1 and Yoshiaki Yasuno 1,* |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 39 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2601-10327
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Neural-network-based high-speed and high-definition full-field dynamic optical coherence tomography Journal: opticajournal Publication type: Research Article Suzuyo Komeda, 1 Nobuhisa Tateno, 1 Yusong Liu, 1 Rion Morishita, 1 Xibo Wang, 1 Ibrahim Abd El-Sadek, 1,2 Atsuko Furukawa, 3 Satoshi Matsusaka, 3 Shuichi Makita, 1 and Yoshiaki Yasuno 1,* Abstract A neural-network (NN)-based method for high-speed, high-definition dynamic optical coherence tomography (DOCT) using full-field swept-source optical coherence microscopy (FF-SS-OCM) is demonstrated. FF-SS-OCM provides high-definition OCT images, but, particularly in DOCT imaging, it results in a significant enlargement of the data size and subsequently long data streaming and processing time, which prevents high-throughput imaging. We address this issue by introducing an NN-based DOCT method that generates high-definition logarithmic intensity variance (LIV) -based DOCT images from only four OCT volumes, whereas the conventional method required 32 volumes. The NN model successfully generates an LIV image that is qualitatively and quantitatively similar to the LIV image computed from 32 volumes. This approach significantly reduces data size, transfer time, and processing time for DOCT imaging by a factor of eight. Specifically, these were reduced from 42 GB to 5.3 GB, 7 min to 55 s, and 4 hours to 30 min, respectively. 1 Introduction In recent years, advancements in cultivation technology have made in vitro samples increasingly functional [ 1 ] and allowed them to better mimic living tissues [ 2 ] . Consequently, in vitro samples have become essential for drug development and large-scale screening. Simultaneously, the advancement of in vitro samples has increased the need for high-quality imaging modalities to extract their structural and functional information. To achieve the structural imaging, bright-field microscopy has been typically used due to its high resolution [ 3 ] . However, since it lacks depth resolution, the structural imaging cannot be achieved volumetrically. In contrast, to extract the functional information, fluorescence microscopy has been widely used [ 4 , 5 , 6 ] . Although fluorescence microscopy has target cell specificity, the procedure usually requires markers. And hence, this modality is typically invasive. Additionally, the imaging penetration is limited to within a-few-hundred micrometers. Optical coherence tomography (OCT) is an emerging modality that provides non-invasive and volumetric imaging. It has been used for the imaging of in vitro samples, such as tumor spheroids [ 7 ] , and has visualized their internal structure. However, two problems make OCT a sub-optimal modality. One is insensitivity to intratissue activity. The other is a trade-off between lateral resolution and depth of focus (DOF). The first problem has been recently addressed by dynamic OCT (DOCT), which visualizes intratissue activity without any labels [ 8 , 9 , 10 , 11 ] . The second problem has been partially resolved by several computational refocusing methods, such as digital holographic methods that invert defocusing [ 12 , 13 ] and interferometric synthetic aperture microscopy [ 14 , 15 , 16 ] . However, there is an inevitable problem for widely used conventional point-scanning OCT. Since the conventional point-scanning OCT has a confocal pinhole, it reduces the singly scattered light from a scatterer as the defocus increases. Namely, the confocal pinhole still limits the imaging depth even if the lateral resolution is restored by the computational refocusing [ 17 ] . To overcome this point, full-field swept-source optical coherence microscopy (FF-SS-OCM) has been recently developed [ 18 , 19 , 20 , 21 ] . Due to the lack of a confocal pinhole, FF-SS-OCM is not affected by depth-dependent signal decay caused by the confocality. Additionally, it enables the usage of a high-NA objective, which leads to high lateral resolution. By combining FF-SS-OCM with computational refocusing, high lateral resolution and long DOF are achieved simultaneously [ 18 , 21 ] . Recently, FF-SS-OCM has been combined with DOCT to make OCT much more suitable for in vitro sample imaging. This combination, denoted as FF-DOCT, can achieve high-resolution and label-free intratissue activity imaging with a longer imaging depth than conventional point-scanning OCT [ 21 ] . However, FF-DOCT still suffers from a significant problem caused by its high-resolution nature. Since high-resolution imaging naturally requires high pixel densities, i.e., high definition, the data size of FF-SS-OCM becomes inevitably large. In addition, DOCT requires a large number of repeatedly acquired OCT images at the same location. Consequently, the combination of FF-SS-OCM with DOCT further increases the data size, which leads to significantly long data streaming time and long data processing time. For instance, the FF-SS-OCM developed in Ref. [ 21 ] provides 896 \times 768 pixels in the lateral direction and requires a 32-image repeating acquisition for DOCT imaging, which leads to around 10 min including measurement time and data transfer time from the camera to the PC. For example, if all samples in a 96-well plate need to be measured, data acquisition takes over 10 hours. Additionally, data processing time, including OCT reconstruction, computational refocusing, and DOCT computation, takes around 4 hours even for a single DOCT dataset. This problem significantly hinders the application of FF-DOCT for high-throughput imaging such as large-scale screening. To reduce the number of images for DOCT, neural networks (NNs) have been recently employed. Liu et al. demonstrated NN-based DOCT generation [ 22 ] , which can generate a logarithmic intensity variance (LIV) image [ 23 , 24 ] from only 4 images, which is one-eighth of the conventionally required 32 images. However, the application of this method to FF-DOCT is not straightforward. First, the original NN model in Ref. [ 22 ] was solely trained by the conventional point-scanning OCT data, and hence this ready-made NN model cannot be used directly with FF-SS-OCM data. Another strategy could be training an NN model from scratch using FF-SS-OCM data. However, this strategy is unfeasible because it requires a large number of FF-DOCT datasets and, as mentioned, the acquisition and computation of a single FF-DOCT volume take more than 4 hours. To overcome these issues, we hypothesized that a model refinement strategy, that is additional training with a limited amount of FF-DOCT data on the NN model established for point-scanning OCT, would make the model applicable to FF-SS-OCM data and enable high-speed FF-DOCT imaging. In this paper, we demonstrate high-speed FF-DOCT generation, where the NN model established for point-scanning OCT with relatively low resolution [ 22 ] (denoted as the basement NN model) is additionally trained by a limited number of FF-DOCT datasets to generate an LIV image from only 4 OCT images. The refined NN-generated LIV image was subjectively and objectively compared with conventional LIV images (i.e., the ground truth images) and also with the basement NN-generated LIV images. Consequently, the size of an FF-DOCT dataset is reduced from 42 GB to 5.3 GB. This data size reduction shortened the data transfer time and the data processing time from around 7 min to 55 s and 4 hours to 30 min, respectively. 2 Principle 2.1 Basement NN model Figure 1: NN architecture used for LIV generation. The NN consists of three parts: an encoder (red dashed-line box), a decoder (blue dashed-line box), and a skip connection (brown arrows). The input to the NN is a set of four cross-sectional OCT images, which were acquired at the same position in the sample but at different time