Read Robotic Tele-Operation for Upper Aerodigestive Tract Microsurgery: System Design and Validation by Giovani Braglia, José Jair Alves Mendes Junior, Augusto Tetsuo Prado Inafuco, Federico Mariano, Leonardo S. Mattos (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-06617.txt.
Introduction
Giovani Braglia and co-authors design a robotic tele-operation system for microsurgery in 2026. Their target is the upper aerodigestive tract, inside the throat. Such treatments often employ transoral laser microsurgery for delicate procedures.
In that surgery, a laser beam cuts target tissue precisely. Forceps grasp, manipulate, and stabilize tissue within the tract meanwhile. Procedures include removal of tumors or polyps from those passages. Tele-operation would let a surgeon control instruments remotely and steadily. The paper covers system design and validation of their setup. Medical robotics readers get a full pipeline, from design to tests. It aims at steadier, safer work in a tight surgical space.
Catalog record
| CREATOR | Giovani Braglia, José Jair Alves Mendes Junior, Augusto Tetsuo Prado Inafuco, Federico Mariano, Leonardo S. Mattos |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 24 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2601-06617
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Robotic Tele-Operation for Upper Aerodigestive Tract Microsurgery: System Design and Validation Giovani Braglia, José Jair Alves Mendes Junior, Augusto Tetsuo Prado Inafuco, Federico Mariano, Leonardo S. Mattos Abstract Upper aerodigestive tract (UADT) treatments frequently employ transoral laser microsurgery (TLM) for procedures such as the removal of tumors or polyps. In TLM, a laser beam is used to cut target tissue, while forceps are employed to grasp, manipulate, and stabilize tissue within the UADT. Although TLM systems may rely on different technologies and interfaces, forceps manipulation is still predominantly performed manually, introducing limitations in ergonomics, precision, and controllability. This paper proposes a novel robotic system for tissue manipulation in UADT procedures, based on a novel end-effector designed for forceps control. The system is integrated within a teleoperation framework that employs a robotic manipulator with a programmed remote center of motion (RCM), enabling precise and constrained instrument motion while improving surgeon ergonomics. The proposed approach is validated through two experimental studies and a dedicated usability evaluation, demonstrating its effectiveness and suitability for UADT surgical applications. I Introduction Telerobotic surgery enables the transfer of a surgeon’s sensorimotor skills to a robotic platform, allowing surgical interventions to be performed on the patient’s body through a master-slave control architecture. On one hand, by decoupling the surgeon from the operative site, telesurgery has marked a significant step forward in surgical technology, enabling procedures to be carried out remotely with enhanced accuracy and precision [ 13 , 1 ] . On the other hand, the integration of advanced sensing and haptic feedback within telerobotic systems further improves the surgeon’s sensory awareness and motor control, contributing to increased precision during manipulation and, ultimately, to improved surgical procedures and patient outcomes [ 16 ] . Indeed, the benefits of robot-assisted telesurgery are increasingly recognized in healthcare, leading to its adoption in a growing number of surgical procedures; however, several application domains remain unexplored [ 4 ] . Upper aerodigestive tract (UADT) diseases fall within this category. Tumors affecting this anatomical region represent, for instance, the sixth most common type of cancer and show a strong prevalence among smokers. In recent years, UADT conditions have attracted increasing research attention for several reasons. First, advances in medical imaging and artificial intelligence have enabled improved diagnostic capabilities, including tumor segmentation [ 10 ] and analysis [ 17 ] . Second, surgical treatments have become more accurate and less invasive due to techniques such as transoral laser microsurgery (TLM) [ 15 , 5 ] . In TLM, the surgeon employs a laser micromanipulator to perform precise laser ablation for the resection of pathological tissue, such as tumor regions [ 12 ] . This approach benefits patients by enabling minimally invasive and highly accurate cuts, resulting in reduced trauma and faster postoperative recovery [ 2 , 5 ] . While tissue ablation is executed by the laser micromanipulator, tissue manipulation and removal are still performed manually using forceps. Fig. 1 : OR setup example during UADT procedures. The typical operating room (OR) setup for TLM is schematically illustrated in Fig. 1 . During the procedure, the patient’s mouth is kept open using a laryngoscope, which is inserted into the oral cavity and mechanically fixed to the operating table. A surgical endoscope camera is employed to provide a magnified view of the UADT, while the surgeon operates the laser micromanipulator through a dedicated user interface to perform tissue ablation [ 5 ] . Prior to laser ablation, the surgeon inserts forceps through the laryngoscope to grasp and manipulate the target tissue, improving visibility and positioning of the area of interest. As shown in Fig. 1 , this manipulation is currently performed manually, which may introduce limitations such as hand tremor, grasp instability, and surgeon fatigue, especially during prolonged or repeated interventions [ 14 ] . Motivated by recent advances in telesurgery, this work proposes a novel teleoperated system to replace manual tissue manipulation in transoral microsurgery. Previous approaches addressing this application have been reported in [ 6 , 7 ] ; however, the proposed system advances the state of the art by reducing hardware complexity and introducing additional capabilities, such as the software enforcement of a remote center of motion (RCM) to facilitate forceps manipulation within the laryngoscope. The resulting proposed approach aims to improve manipulation stability and reduce surgeon effort while remaining fully compatible with the operational and spatial requirements of TLM. I-A Motivations and Contributions Because UADT microsurgery relies on manual tissue manipulation, procedural performance may be affected by hand tremor, unstable grasping, and fatigue, particularly in long or repetitive surgical tasks [ 14 ] . This paper addresses these limitations by proposing a novel teleoperation framework that assists the surgeon in performing tissue manipulation through a robotic system. The main contributions of this work are threefold: (i) the design of a novel computer-controlled end-effector for forceps manipulation; (ii) the development of a complete teleoperation pipeline for robotic control based on a remote center of motion (RCM) constraint; and (iii) an extensive experimental validation, including a pilot user study involving the manipulation of a silicone vocal fold. The remainder of the paper is organized as follows. Section II describes the components of the proposed framework. Section III details the experimental setup and presents the key results. Section IV discusses the findings and concludes the paper. II Materials and Methods Fig. 2 : Proposed teleoperation system. On the surgeon side, the master operator takes control by simultaneously pressing two enabling pedals, thus sending velocity commands with the remote controller. On the patient side, the slave robot moves our custom end-effector, whose open-close movements are controlled directly from the operator. The description of the proposed telesurgery system for UADT treatments is depicted in Fig. 2 . The system consists of a master (surgeon) and a slave (patient) side. On the surgeon side, the operator sit on a chair where he/she can visualize the operating site through a 2D monitor displaying the view of an exoscopic camera located at the patient side. Visualization of the target tissue is performed through the laryngoscope, providing the surgeon a magnified view of the UADT [ 2 ] . On the patient side, the proposed forceps control end-effector is mounted on a robot manipulator. The robot reads movements commands from the surgeon side, sent through an haptic device located on the surgeon desk. Commands are read by the robot only if two safety foot switch are pressed simultaneously. Finally, the haptic device also allows to send open/close commands, which are read and processed by the end-effector controller to open/close the forceps jaws. In the next paragraphs, the architecture and control aspects are detailed. The reader is also encouraged to have a look at the paper’s video to have a comprehensive view of how the proposed system works. II-A System setup The designed forceps control end-effector is shown on the right side of Fig. 2 . The tool consists of an aluminum structure approximately 20 cm in length and weighing 2.1 kg, mounted on a Franka Emika Panda robot. The distal end of the aluminum structure is designed to accommodate a Karl Storz surgical forceps, which can be easily mounted or replaced using an aluminum clamp secured by a hand screw.