Impact of Cold Noise on the tracking performance of ATLAS ITk short strip barrel modules using a charged particle beam Journal: Nuclear Instruments and Methods A
A. Affolder, J.-H. Arling, K. S. V. Astrand, I. Benaoumeur, J. Bucko, S. Diez-Cornell, B. J. Gallop, N. Ghorbanian, Y. He, C. M. Helling, N. Hessey, L. Huth, C. Jessiman, C. T. Klein, J. S. Keller, J. Kroll, J. Kvasnicka, K. Mauer, A. Murphy, L. Poley, D. M. Portillo Quintero, P. W. Phillips, R. Pri · 2026
Read Impact of Cold Noise on the tracking performance of ATLAS ITk short strip barrel modules using a charged particle beam Journal: Nuclear Instruments and Methods A by A. Affolder, J.-H. Arling, K. S. V. Astrand, I. Benaoumeur, J. Bucko, S. Diez-Cornell, B. J. Gallop, N. Ghorbanian, Y. He, C. M. Helling, N. Hessey, L. Huth, C. Jessiman, C. T. Klein, J. S. Keller, J. Kroll, J. Kvasnicka, K. Mauer, A. Murphy, L. Poley, D. M. Portillo Quintero, P. W. Phillips, R. Pri (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-05393.txt.
Introduction
Tony Affolder and 25 co-authors measure how a cold noise fault affects detector modules built for the upgraded ATLAS experiment in a 2026 paper. The ATLAS inner tracker will become a full silicon detector for the High-Luminosity Large Hadron Collider, and its modules must exceed strict efficiency and noise occupancy targets. During pre-production, many short-strip modules showed cold noise: clusters of strips with very high noise when operated below a threshold temperature.
The team studies the fault's impact on tracking performance using a charged particle beam, part of a large collaboration effort to ensure production quality. Understanding whether cold noise spoils real tracks decides whether affected modules can be accepted, repaired, or must be rejected before installation deep inside ATLAS.
Catalog record
| CREATOR | A. Affolder, J.-H. Arling, K. S. V. Astrand, I. Benaoumeur, J. Bucko, S. Diez-Cornell, B. J. Gallop, N. Ghorbanian, Y. He, C. M. Helling, N. Hessey, L. Huth, C. Jessiman, C. T. Klein, J. S. Keller, J. Kroll, J. Kvasnicka, K. Mauer, A. Murphy, L. Poley, D. M. Portillo Quintero, P. W. Phillips, R. Pri |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 33 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2601-05393
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Impact of Cold Noise on the tracking performance of ATLAS ITk short strip barrel modules using a charged particle beam Journal: Nuclear Instruments and Methods A A. Affolder, J.-H. Arling, K. S. V. Astrand, I. Benaoumeur, J. Bucko, S. Diez-Cornell, B. J. Gallop, N. Ghorbanian, Y. He, C. M. Helling, N. Hessey, L. Huth, C. Jessiman, C. T. Klein, J. S. Keller, J. Kroll, J. Kvasnicka, K. Mauer, A. Murphy, L. Poley, D. M. Portillo Quintero, P. W. Phillips, R. Privara, E. Torres Reoyo, P. Tuma, M. Warren Abstract The inner tracking system of the ATLAS experiment will be upgraded to a full silicon detector in 2030 for HL-LHC. The new tracking system is called ITk, the Inner Tracker. It is required to be operable with efficiency higher than 99% and noise hit occupancy smaller than 0.1%. During the pre-production phase of the ITk project, many short-strip modules were observed to exhibit so-called "Cold Noise (CN)", wherein clusters of strips displayed very high noise when the modules were operated at temperatures below − 35 ° -35\degree C. To investigate the CN impact and ensure the quality of module production, huge amount of effort have been put in by the collaboration. This paper focuses on the impact of CN on the tracking performance by examining two short strip modules that exhibit CN: one is non-irradiated, while the other one has been irradiated to the maximum expected end-of-lifetime fluence. For each module, the global and single strip tracking performance are evaluated. The global performance study shows that the non-irradiated module can be operated within specifications with a threshold around 1fC, but it is not possible to operate the irradiated module as required. In the single strip analysis, it was found that while CN does not affect the charge collection, it reduces the operating window and leaves less margin for detector operation. In the non-irradiated module, less than 3% of strips fail the detector requirements in the CN regions. For the irradiated module, about 20% of strips fail the requirements in the low CN region and around 52% fail in the high CN region. The fraction of strips that cannot operate due to CN throughout their lifetime can be predicted according to the measured Q c no \mathrm{Q_{c}^{no}} and its expected median collected charge. If the hit noise occupancy caused by CN is kept below 1% with a threshold greater than 0.45 fC, approximately 60% of strips could meet the operating requirements by the end of detector’s lifetime. Thus, the module is likely to satisfy the operating requirements in terms of global efficiency and global noise occupancy. 1 Introduction The Inner Tracker (ITk) is a full-silicon tracking detector developed for the ATLAS experiment, specifically designed for the High Luminosity phase of the Large Hadron Collider (HL-LHC). It comprises both pixel and strip detectors. The strip detectors are positioned in the outer layers of the ITk, including the barrel and end-cap regions, ensuring coverage of the entire radius of the solenoid’s inner bore. The total coverage area is approximately 165 m 2 , consisting 17888 modules. Among these modules, 21.3% are short strip modules, covering the innermost layers of the barrel region. During the pre-production phase of the ITk project, many short strip modules exhibited clusters of channels with noise level falling outside of the required specifications when tested at operating temperatures of -35\degree C or lower; this issue is referred to as "Cold Noise (CN)". Further investigations revealed that this CN is caused by vibrating capacitors on a flexible printed circuit board (PCB) glued to the sensor surface [ 8 ] . These vibrations couple into the silicon sensor via the glue and generate unwanted electrical signals. The ITk strip modules are required to achieve tracking efficiency higher than 99% and to keep hit noise occupancy lower than 0.1% throughout their operational lifetime. This paper aims to highlight the impact of CN on tracking performance and to determine whether the modules can operate within specifications when affected by CN. The input data for the analyses in this paper are from two short strip modules with identified CN: one is non-irradiated, while the other one has been sensor-irradiated to a fluence of 1.1\times 10^{15} 1 MeV \mathrm{n_{eq}/cm^{2}} using 24 GeV protons from the IRRAD facility [ 13 ] . This corresponds to the maximum expected end-of-lifetime fluence for any short strip module, including a 50% safety factor. CN modules have different levels and patterns of noise. Therefore, in this paper, both the single strip performance as a function of its noise and the global performance are studied, so that the results can be extrapolated to other modules. 2 ITk Short Strip Module A short strip module [ 15 ] consists of one sensor, two low-mass PCBs known as hybrids that house the readout and control ASICs — the ABCStar and HCCStar — as well as a power board. The power board features a DC-DC converter, a GanFET transistor, and a monitoring and control ASIC (AMACv2). An exploded view of a short strip module is shown in Figure 1 . The sensor of the ITk short strip module is of the n + -in-p type, produced from a 6-inch float-zone p-type silicon wafer [ 16 ] . It is divided into four segments, with 1282 parallel strips per segment, which includes 1280 readout strips and one dummy strips on each side to help shape the electric field. Each strip has a pitch of 75.5 \mathrm{\SIUnitSymbolMicro m} and a length of about 2.5 cm. The flex hybrids and the power board are glued directly to the silicon sensor using electronics-grade epoxy. Figure 2(a) displays a short strip module mounted on its test frame. In the picture, the hybrids glued onto the inner two segments of the sensor and the power board is glued between the hybrids. Each hybrid holds 10 ABCStar read-out chips [ 12 , 5 ] , with each ABCStar chip providing binary output for 256 channels. Half of the channels come from the segment beneath the hybrid, and the other half come from the segment away from the hybrid. Figure 2(b) illustrates the numbering scheme used in this paper. The hybrid on the lower half of the module communicates with the lower two segments, labeled s20 and s21. The ABCStar chips, arranged from right to left, are labeled from 0 to 9. Similarly, the active strips in both s20 and s21 are numbered from 0 to 1279 from right to left. The second hybrid, positioned at the upper part of the module, communicates with the upper two segments, labeled s22 and s23. For these chips and strips, the numbering scheme follows a left-to-right order. Vibrating components originate from the DC-DC converter, and CN only occurs in the sensor segments overlapping with the power board, i.e. s20 and s22, the investigation in this paper focus on these segments, with the other two segments for reference. Figure 1 : Exploded view of a short strip barrel module with all relevant components. Taken from [ 15 ] . (a) Module (b) Numbering scheme Figure 2 : (a) A physical short strip module attached to its test frame. (b) Numbering scheme for the SS module, with