A current source with metrological precision made on a 300mm silicon MOS process
Nathan Johnson, Stefan Kubicek, Julien Jussot, Yann Canvel, Kristiaan De Greve, M. Fernando Gonzalez-Zalba, Ross C. C. Leon, John J. L. Morton · 2026
Read A current source with metrological precision made on a 300mm silicon MOS process by Nathan Johnson, Stefan Kubicek, Julien Jussot, Yann Canvel, Kristiaan De Greve, M. Fernando Gonzalez-Zalba, Ross C. C. Leon, John J. L. Morton (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-03916.txt.
Introduction
Nathan Johnson and seven co-authors report a single-electron current source built on an industrial three hundred millimeter silicon manufacturing process. Electrical current is now defined through the electron's charge, but making a practical standard from single electrons is hard. Error rates must be extraordinarily low, and many sources must run in parallel to reach useful nanoampere currents. A gate-defined quantum dot made with industry-grade fabrication offers a route to that scale.
Measurements showed an error rate below the threshold required to realize the SI ampere, among the lowest ever reported. Comparisons with established quantum tunneling models further supported the device's accuracy. Because the process is the same kind used for commercial chips, control and measurement electronics could eventually be integrated alongside many sources, a concrete step toward chip-scale current standards.
Catalog record
| CREATOR | Nathan Johnson, Stefan Kubicek, Julien Jussot, Yann Canvel, Kristiaan De Greve, M. Fernando Gonzalez-Zalba, Ross C. C. Leon, John J. L. Morton |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 35 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2601-03916
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A current source with metrological precision made on a 300mm silicon MOS process Nathan Johnson, Stefan Kubicek, Julien Jussot, Yann Canvel, Kristiaan De Greve, M. Fernando Gonzalez-Zalba, Ross C. C. Leon, John J. L. Morton Abstract Although the measurement of current is now defined with respect to the electronic charge, producing a current standard based on a single-electron source remains challenging. The error rate of a source must be below 0.01 ppm, and many such sources must be operated in parallel to provide practically useful values of current in the nanoampere range. Achieving a single electron source using an industrial grade 300 mm wafer silicon metal oxide semiconductor (MOS) process could offer a powerful route for scaling, combined with the ability for integration with control and measurement electronics. Here, we present measurements of such a single-electron source indicating an error rate of 0.008 ppm, below the error threshold to satisfy the SI Ampere, and one of the lowest error rates reported, implemented using a gate-defined quantum dot device fabricated on an industry-grade silicon MOS process. Further evidence supporting the accuracy of the device is obtained by comparing the device performance to established models of quantum tunnelling, which reveal the mechanism of operation of our source at the single particle level. The low error rate observed in this device motivates the development of scaled arrays of parallel sources utilising Si MOS devices to realise a new generation of metrologically accurate current standards. The 2019 redefinition of the International System of units (SI) determined a number of physical constants to have precise values Bureau International des Poids et Mesures 2024 ; Stock et al. 2019 . The unit of electrical current, the Ampere, is now defined as a number of elementary charges e moving in a second s , and thus replaces the cumbersome definition that referenced the Ampere to the magnetic force between two currents passing parallel wires Giblin et al. 2012 ; Pekola et al. 2013 . Semiconductors provide a natural platform to realise this new current standard, where there has been significant progress in the manipulation of single-electron currents Philips et al. 2022 ; Fletcher et al. 2023 ; Thomas et al. 2025 ; Yamahata et al. 2019 ; Künne et al. 2024 . However, realising this new Ampere at the required metrological precision, with an error below 0.01 ppm (or 10^{-8} ) in the charges transferred individually per unit time, has proven challenging Pekola et al. 2013 ; Kaestner and Kashcheyevs 2015 . Whilst there have been attempts to utilise the bulk flow of charge to realise a current source Rodenbach et al. 2025 ; de Graaf et al. 2018 ; Djordjevic et al. 2025 , quantum dot (QD) based sources have been promising both in precision and in applications such as forming nano-electronic circuits, or in closing the quantum metrological triangle Keller 2008 ; Scherer and Schumacher 2019 . Quantum dot single-electron sources have been demonstrated in several materials including GaAs, graphene and silicon Blumenthal et al. 2007 ; Connolly et al. 2013 ; Yamahata et al. 2016 ; Giblin et al. 2012 ; Giblin et al. 2019 . In particular devices based on GaAs/AlGaAs heterostructures and Si nanowires have shown error rates close to the required 0.01 ppm level at frequencies approaching 1 GHz, generating currents at the \sim 100 pA level Giblin et al. 2019 . To be of practical benefit, QD current sources aiming to realize the current standard should produce (i) a current on-demand at the nanoampere level Pekola et al. 2013 ; Stock et al. 2019 , which may require the parallelization of multiple QD sources, (ii) be embeddable with other electronic elements such as microwave generators and transimpedance amplifiers that would complement the current standard and (iii) deployable without using a calibration chain. Such requirements have motivated work on silicon-based QD sources Jehl et al. 2013 ; Yamahata et al. 2011 ; Rossi et al. 2014 over GaAs that lacks the maturity of silicon as a large scale semiconductor manufacturing platform. Further, GaAs-based devices typically require high magnetic fields (10 - 14 T). Recent results report the co-integration of single-electron sources with on-chip signal generation and addressing electronics Dash et al. 2025 and the demonstration of parallel operation of up to four Si nanowire devices Yamahata et al. 2025 . These results demonstrate the potential of SiMOS QDs as a platform for parallelized current sources, and how moving to industrial grade fabrication processes could enable integrated metrologically-precise on-chip current generation. However, in both cases above the precision falls several orders of magnitude short of the required 10^{-8} error. Here, we demonstrate the significant potential of current sources based on industrial-grade 300 mm wafer silicon CMOS, showing evidence of metrological precision at zero applied magnetic field. The device benefits from significant tunability, allowing for potential scalability by overcoming recently reported limitations Yamahata et al. 2025 , enabling parallelisation of devices and simplification, for example by using shared voltage schemes, in addition to the advantages of industrial CMOS processing. Our study encourages further work to leverage the large-scale integration capabilities of silicon to (i) produce high current sources by parallelization of homogenous devices and (ii) integration with additional support electronics. Further, we present a detailed analysis method and understanding of the single-electron transfer process in our device. Figure 1: A single-electron pump produced on a Si MOS 300 mm process. (a) Illustration of the device design and electrical connections with expected potential profile beneath. (b) With each cycle of V_{\rm G1}^{\rm ac} , charge is (i) loaded into the inter-gate QD; (ii) Sequential back-tunnelling of charge occurs, leaving capture of n charges; (iii) the charge(s) are isolated in the dynamic QD; finally (iv) the charge(s) are ejected to the drain forming the pumped current I_{p}=nef . (c) Measured current as a function of dc gate voltages, with V_{\rm G1}^{\rm ac}\sim 0.8 V at 100 MHz. Colour scale shows I_{p}/ef , denoting the number of charges n pumped per cycle. Contour lines are at unit increment. (d) Current measured as a function of the dc voltage on V_{\rm G2} (dashed line in (c)) with a fit (red) to the decay cascade model (Eq. 1 ) verifying the sequential tunnelling regime of operation. (ii) Fitting the deviation from single-electron tunnelling, \left|1-I_{p}/ef\right| indicates an error <10^{-8} . I Device and Accuracy Figure 1 (a) shows a sketch of our device (see Methods for further details) and the expected potential profile landscape created upon energising the gates. A channel is defined under an accumulation gate (TG) and between two confinement gates (C1, C2) forming a path between source and drain ohmic contacts. In the active region of the device, gates (G1, G2) define tunnel barriers in the channel, forming the QD between them. In regular operation, V_{\rm C1,2}= 0 V, and ambient temperature is T=10 mK. We add a sinusoid ac voltage V_{\rm G1}^{\rm ac} to fixed dc offset V_{\rm G1}^{\rm dc} , to drive the single-electron source at a frequency f . For each period of V_{\rm G1}^{\rm ac} , n charges (with charge -e ) pass from the source to the QD to the drain, producing a dc pumped current I_{p}=nef . The operation of