Optimal Dispatch of Electricity and Water in Renewable-Integrated Desalination Plants
Ahmed S. Alahmed, Audun Botterud, Saurabh Amin, Ali T. Al-Awami · 2026
Read Optimal Dispatch of Electricity and Water in Renewable-Integrated Desalination Plants by Ahmed S. Alahmed, Audun Botterud, Saurabh Amin, Ali T. Al-Awami (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-02243.txt.
Introduction
Ahmed S. Alahmed, Audun Botterud, and Saurabh Amin study how a desalination plant that makes fresh water can also help run an electric power grid. Their plant joins heat based generation, membrane units that can be turned up or down, and renewable power. The plant sells water to a utility and can buy or sell electricity as its own needs change.
Inside, the authors build a math model for scheduling the plant to earn the most profit while respecting how the machines and markets work. They find a simple threshold rule, worked out in near closed form, that tells the plant when to switch modes. Tests in simulation show clear gains over simpler methods and show how prices and technology choices change profit.
Catalog record
| CREATOR | Ahmed S. Alahmed, Audun Botterud, Saurabh Amin, Ali T. Al-Awami |
|---|---|
| YEAR | 2026 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 76 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2601-02243
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Optimal Dispatch of Electricity and Water in Renewable-Integrated Desalination Plants Ahmed S. Alahmed, Audun Botterud, Saurabh Amin, Ali T. Al-Awami Abstract We develop a mathematical framework for the optimal dispatch of flexible water desalination plants (WDPs) as hybrid generator-load resources. WDPs integrate thermal generation, membrane-based controllable loads, and renewable energy sources, offering unique operational flexibility for power system operations. They can simultaneously participate in two markets: selling desalinated water to a water utility, and bidirectionally transacting electricity with the grid based on their net electricity demand. We formulate the dispatch decision problem of a profit-maximizing WDP, capturing operational, technological, and market-based coupling between water and electricity flows. The threshold-based structure we derive provides computationally tractable coordination suitable for large-scale deployment, offering operational insights into how thermal generation and membrane-based loads complementarily provide continuous bidirectional flexibility. The thresholds are analytically characterized in closed form as explicit functions of technology and tariff parameters. We examine how small changes in the exogenous tariff and technology parameters affect the WDP’s profit. Extensive simulations illustrate the optimal WDP’s operation, profit, and water-electricity exchange, demonstrating significant improvements relative to benchmark algorithms. I Introduction T he ongoing transformation of power systems, driven by increasing penetration of variable renewables, creates growing demand for flexible resources that can provide bidirectional grid services. Water desalination plants (WDPs), 1 1 1 By WDP, we also refer to water treatment plants. The two differ only in terms of the salinity coefficients considered [ 25 ] . representing approximately 5-12% of total electricity consumption in Middle East countries [ 29 ] with 7% per annum global capacity growth since 2010 [ 9 ] , are evolving from passive to active market participants capable of dynamically adjusting operations in response to price signals and renewable energy availability. Unlike conventional generators that can only supply power or loads that can only reduce consumption, modern WDPs integrating both thermal and renewable generation and membrane-based loads function as hybrid generator-load resources with continuous bidirectional flexibility. With global freshwater demand projected to exceed available supply by 40% by 2030 [ 15 ] , WDPs have become an increasingly vital component of sustainable water infrastructure in various parts of the world. As the demand for seawater and wastewater treatment continues to grow, so does the need for efficient and sustainable operation of WDPs. These facilities are inherently energy-intensive, consuming substantial amounts of energy to drive both thermal- and membrane-based desalination processes [ 10 ] . Consequently, there is growing interest in integrating desalination operations with renewable energy sources and advanced dispatching strategies to reduce operational costs and environmental impact [ 12 ] . In parallel, the ongoing transformation of power systems, driven by increasing penetration of renewables and the rise of decentralized energy resources, has given rise to novel opportunities and challenges at the water-energy nexus. In this context, WDPs are evolving from passive energy consumers to active participants in electricity markets, capable of dynamically adjusting their operations in response to electricity price signals and renewable energy availability. Co-optimizing water and power dispatching, a global research priority in the water-energy nexus [ 26 ] , is crucial for ensuring economic viability and grid-supportive behavior. This paper develops an analytical framework for the optimal dispatch of WDPs operating as hybrid generator-load resources (Fig. 1 ). A key challenge lies in utilizing the complementarities between the load-generator resources within the plant, in addition to optimally dispatching both water and electricity transactions with water and electric utilities. Fig. 1: WDP as a hybrid generator-load resource. The water (power) output of the thermal desalination plant (TDP) and reverse osmosis desalination plant (RODP) is denoted by w_{h},w_{r}\;(q_{h},q_{r})\in\mathbb{R}_{+} , respectively. The renewable generation and net consumption are denoted by g\in\mathbb{R}_{+} , and z\in\mathbb{R} . I-A Related Work One of the earliest examinations of water-power systems is Gleick’s seminal review [ 14 ] , which highlighted the fundamental interdependence between water and power systems: energy is required for water extraction, treatment, and transport, while water is essential for electricity generation and fuel production. This foundational perspective has since motivated a broad literature on modeling, coordinating, and optimizing coupled water-energy infrastructures. In energy-abundant regions, TDPs often operate alongside power generation, producing freshwater as the primary output and electricity as a by-product. These colocated systems leverage shared thermal and electrical infrastructure, resulting in strongly coupled operational behavior. For instance, [ 28 ] propose dynamic, physics-based models of such integrated systems, emphasizing the value of coordinated control between thermal power and thermal desalination units. Reverse osmosis (RO) has emerged as the dominant desalination technology, favored for its modularity and superior energy efficiency. Recent estimates suggest that RO accounts for approximately 69% of global installed desalination capacity [ 8 ] . As RO units rely predominantly on electricity from the grid, they can function as substantial and flexible loads within the power system. Several recent studies [ 13 , 27 , 4 , 17 ] explore the integration of RODPs with variable renewable energy sources (e.g., solar and wind), primarily through simulation-based energy management frameworks designed to reduce operational costs, emissions, and improve grid compatibility. In particular, [ 17 ] present an energy management system for a standalone wind-powered desalination microgrid, highlighting coordinated control strategies for matching variable generation to water demand. However, these contributions remain largely simulation-based and typically treat the power system as an exogenous input, without explicitly modeling the endogenous coupling between the water and energy sectors. More recent efforts [ 21 , 22 , 11 ] address this gap by developing numerical co-optimization models for water-energy microgrids and joint RO-power dispatching under dynamic demand, grid constraints. These studies also explore the role of RO in demand response and grid services. The work in [ 23 ] formulates a security-constrained unit commitment problem to coordinate the operation of RO-only desalination plants and power plants and showed a reduction in the system’s operating costs by 5% to 8% under the IEEE 118-bus system. Despite these advances, existing approaches are predominantly computational, with limited analytical insight into structural properties of the optimal dispatching problem, an issue that our work aims to address. Beyond RO-power coordination, recent work expands to decentralized water-energy nexus markets and flexible cross-sector operations. [ 31 ] propose a blockchain-based transactive framework for interconnected water-energy hubs, showing performance gains under spatial-temporal uncertainty. Similarly, [ 6 ] develops a watershed-electricity model that exploits hydrological flexibility, through dynamic river conditions and pump dispatching, to support distribution network operations. While demonstrating the benefits of decentralized coordination, these studies do not consider colocating and the unique operating regimes of joint RO and TDP systems. The studies in [ 25 , 30 , 16 ] propose models for coordinating water and power distribution systems to minimize operational costs of meeting water and electricity demands by leveraging variable speed pumps and water tanks. However, these models do not incorporate colocated renewable energy sources or bidirectional energy transactions between WDPs and the electric grid, limiting their ability to fully optimize integrated resource management. Although significant progress has been made, most existing work models RODP and TDP separately, without capturing their distinct operational features or interactions with water and power systems, particularly when colocated with renewables. This siloed treatment overlooks opportunities for coordinated real-time