Impact Assessment of Heterogeneous Grid Support Functions in Smart Inverter Deployments PubID: pubid: 979-8-3315-2503-3/25/$31.00 ©2025 IEEE

S. Gokul Krishnan, Mohd. Asim Aftab, Nabil Mohammed, Shehab Ahmed, Charalambos Konstantinou · 2026

Read Impact Assessment of Heterogeneous Grid Support Functions in Smart Inverter Deployments PubID: pubid: 979-8-3315-2503-3/25/$31.00 ©2025 IEEE by S. Gokul Krishnan, Mohd. Asim Aftab, Nabil Mohammed, Shehab Ahmed, Charalambos Konstantinou (2026) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2601-00289.txt.

Introduction

S Gokul Krishnan leads four coauthors in testing what happens when smart inverters on one grid follow different rule books. Solar power now floods low voltage networks in many places. Standards require inverters to support the grid actively. Each device acts on its own local readings. Mixed control modes can clash when penetration runs high.

Three modes anchor the comparison here. Constant power factor, volt var, and volt watt rules differ in response. Both resistive and inductive feeder types are tested. A real time simulator hosts a true low voltage network model. That setup gives high fidelity readings of the clashes. Efficiency, voltage control, and stability all come under watch. Earlier praise for coordination left this mixed case open. The study fills that gap for grid planners. Uncoordinated diversity itself becomes the risk to manage.

Catalog record

CREATORS. Gokul Krishnan, Mohd. Asim Aftab, Nabil Mohammed, Shehab Ahmed, Charalambos Konstantinou
YEAR2026
COLLECTIONPAPERS
FORMATTXT
FILE SIZE19 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2601-00289

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Impact Assessment of Heterogeneous Grid Support Functions in Smart Inverter Deployments PubID: pubid: 979-8-3315-2503-3/25/$31.00 ©2025 IEEE S. Gokul Krishnan, Mohd. Asim Aftab, Nabil Mohammed, Shehab Ahmed, Charalambos Konstantinou Abstract The decarbonization of the energy sector has led to a significant high penetration of distributed energy resources (DERs), particularly photovoltaic (PV) systems, in low-voltage (LV) distribution networks. To maintain grid stability, recent standards (e.g., IEEE 1547-2018) mandate DERs to provide grid-support functionalities through smart inverters (SIs), which typically operate autonomously based on local measurements. However, as DER penetration increases, uncoordinated control modes of SIs can lead to adverse interactions, compromising system efficiency, voltage regulation, and overall stability. While previous studies have demonstrated the benefits of coordinated inverter control and optimal dispatch strategies, the system-wide impacts of heterogeneous SI groups operating under different control modes remain largely unexamined. This paper addresses this gap by assessing the dynamic interactions among multiple SI groups with varying control strategies, namely: Constant Power Factor (CPF), Volt-VAR, and Volt-Watt modes. Furthermore, the analysis covers both resistive and inductive feeder types. The validation is performed using a real-time setup. The CIRGE low-voltage (LV) distribution network is simulated in the Opal-RT platform as the test network, enabling realistic and high-fidelity evaluation of SI control interactions under practical grid conditions. † † aftertitle: I Introduction The global shift toward decarbonization has accelerated the deployment of renewable energy resources, particularly photovoltaic (PV) systems [ 6 ] . Initially, these distributed energy resources (DERs) were deployed with minimal coordination, as their low penetration posed negligible impact on grid stability. However, with the increasing proliferation of DERs, traditional grid operation and control paradigms have become insufficient. This necessitated the revision of IEEE 1547-2003 and the release of IEEE 1547-2018, which mandates essential grid support functionalities such as voltage, frequency ridethrough, power regulation, and ramp rate control of DERs [ 7 ] . These capabilities are facilitated by smart inverters (SIs), which are capable of dynamically adjusting their power output and can also communicate with the DER aggregators to enhance reliability and resilience. SIs provide advanced ancillary services, including reactive power control (Volt-VAR), active power curtailment (Volt-Watt), frequency stabilization (Frequency-Watt), and ride-through capabilities under abnormal grid conditions [ 10 ] . The majority of SIs utilize preprogrammed control curves that define their active and reactive power responses based solely on local measurements obtained via phase-locked loops (PLLs). This decentralized control architecture enables autonomous inverter operation without requiring a centralized communication framework. However, the control behavior of SIs is highly dependent on their electrical and geographical deployment context [ 1 ] . The selection of SIs operating mode depends on factors such as feeder location/topology, local voltage level, power quality metrics, and utility interconnection standards. For instance, an inverter located at the end of a radial distribution feeder may operate in Volt-Var mode for local voltage support, whereas one near a substation may be configured to maintain a constant power (CPF). Distribution system operators (DSOs) may mandate specific control modes to address feeder-specific constraints or mitigate grid disturbances. As DER penetration continues to increase, the uncoordinated, locally governed operation of SIs can lead to adverse interactions. Since each SI operates independently based on its own local measurements, their collective response may result in control conflicts, reduced voltage regulation effectiveness, or decreased overall system efficiency and stability. Although coordinated PV inverter control strategies have demonstrated benefits such as reduced power curtailment, lower line losses, improved PV hosting capacity, and enhanced system stability [ 8 ] , most existing studies assume homogeneous inverter operation or rely on centralized optimization frameworks [ 4 , 3 ] . The system-level implications of heterogeneous control mode deployment—where different groups of SIs operate under distinct control strategies—remain largely unexplored. In particular, the cross-impact of control mode changes in one SI group on the dynamic performance of other groups within the network has not yet been systematically investigated. To address this research gap, this paper presents a comprehensive impact assessment of heterogeneous grid support functions deployed via SIs in a LV distribution network. A real-time simulation framework is employed using the Opal-RT simulator to model the CIGRE LV distribution network under both resistive and inductive line configurations. This high-fidelity platform enables realistic evaluation and validation of the dynamic interactions among SI groups operating under heterogeneous control modes. This study contributes novel insights into the collective dynamics of SIs with heterogeneous control modes and demonstrates their influence on voltage regulation in distribution networks. The rest of the paper is organized as follows. Section II describes the electric grid architecture and functions of SI. Section III details the system modeling used for the analysis. Section IV presents the simulation results. Finally, Section V concludes the paper. II System Description and Control of SIs This section outlines the fundamental principles governing the relationship between power injections and voltage behavior in electric power systems, with emphasis on the influence of line impedance characteristics. It further introduces widely adopted control strategies of SIs for voltage regulation in low- and medium-voltage networks. II-A Fundamentals of Electric Grid Modeling The coupling between power flows and voltage profiles in electric networks is strongly influenced by the impedance characteristics of the lines. In high-voltage (HV) transmission networks, where line reactance dominates resistance (\frac{X}{R}>>1) , voltage variations are primarily influenced by reactive power flows. In contrast, LV distribution networks exhibit a higher resistance-to-reactance ratios (\frac{R}{X}>>1) , where voltage variations are more sensitive to active power injections [ 5 ] . Fig. 1 : Two-bus network representation. Consider a two-bus network as shown in Fig. 1 , where node A (slack/source) is connected to node B (load/generation point) via an impedance Z_{AB}=R_{AB}+jX_{AB} . Let V_{B} be the complex voltage at node B, with net complex power injection S_{B}=P_{B}+jQ_{B} . Assuming the sending-end voltage V_{A} is fixed at node A, the current flowing through the line is: I_{AB}=(\frac{P_{B}+jQ_{B}}{V_{B}})^{*} (1) Applying Ohm’s law, the complex voltage drop across the line is: \Delta V_{AB}=I_{AB}.(R_{AB}+jX_{AB}) (2) Substituting ( 1 ) into ( 2 ) and separating real and imaginary components, ( 3 ) is obtained. The first term in ( 3 ) is a real term influencing voltage magnitude and the second term is an imaginary term affecting the phase angle. \Delta V_{AB}=\frac{P_{B}R_{AB}+Q_{B}X_{AB}}{|V_{B}|}+j\frac{P_{B}X_{AB}-Q_{B}R_{AB}}{|V_{B}|} (3) In LV networks where R_{AB}\gg X_{AB} , the real part governs the magnitude of voltage deviation. Ignoring the phase angle, the magnitude approximation is: |\Delta V_{AB}|\approx\frac{P_{B}R_{AB}+Q_{B}X_{AB}}{|V_{B}|} (4) Taking the Jacobian of ( 4 ), the sensitivity of voltage to active and reactive power is obtained by taking the partial derivatives as in ( 5 ): |\frac{\delta|\Delta V|}{\delta P_{B}}|=\frac{R_{AB}}{{|V_{B}}|},|\frac{\delta|\Delta V|}{\delta Q_{B}}|=\frac{X_{AB}}{{|V_{B}}|} (5) In resistive grids (LV networks) \frac{R_{AB}}{X_{AB}}\gg 1 , the voltage magnitude is more sensitive to active power injections as expressed in ( 6 ): |\frac{\delta|\Delta V|}{\delta P_{B}}|>>|\frac{\delta|\Delta V|}{\delta Q_{B}}| (6) Conversely, in inductive HV systems: |\frac{\delta|\Delta V|}{\delta Q_{B}}|>>|\frac{\delta|\Delta V|}{\delta P_{B}}| (7) Eqs. ( 6 )-( 7 ) highlight that voltage regulation is governed predominantly by active power in resistive grids and reactive power in inductive networks.. II-B Functions of SIs SIs provide both steady-state and dynamic grid-support function. Their flexibility in changing control modes allows dynamic regulation of active and reactive power, enabling real-time grid support without additional devices (e.g., centralized communication

Read the complete text