ProDM: Synthetic Reality–driven Property-aware Progressive Diffusion Model for Coronary Calcium Motion Correction in Non-gated Chest CT

Xinran Gong, Gorkem Durak, Halil Ertugrul Aktas, Vedat Cicek, Jinkui Hao, Ulas Bagci, Nilay S. Shah, Bo Zhou · 2025

Read ProDM: Synthetic Reality–driven Property-aware Progressive Diffusion Model for Coronary Calcium Motion Correction in Non-gated Chest CT by Xinran Gong, Gorkem Durak, Halil Ertugrul Aktas, Vedat Cicek, Jinkui Hao, Ulas Bagci, Nilay S. Shah, Bo Zhou (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-24948.txt.

Introduction

Xinran Gong, Gorkem Durak, Halil Ertugrul Aktas, and colleagues present ProDM, a diffusion model that corrects heart motion artifacts in coronary calcium scoring from ordinary chest scans. Calcium scoring guides cardiovascular risk, but cardiac and respiratory motion blur calcified lesions in non-gated scans. Gated cardiac scans reduce artifacts yet are limited by requirements and coverage in routine screening.

Their synthetic reality-driven, property-aware progressive diffusion approach aims to recover accurate calcium measures from non-gated images. Medical imaging readers get a method to use scans already taken for other reasons. Reliable incidental calcium scoring could widen risk screening without extra radiation or appointments.

Catalog record

CREATORXinran Gong, Gorkem Durak, Halil Ertugrul Aktas, Vedat Cicek, Jinkui Hao, Ulas Bagci, Nilay S. Shah, Bo Zhou
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE51 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2512-24948

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

ProDM: Synthetic Reality–driven Property-aware Progressive Diffusion Model for Coronary Calcium Motion Correction in Non-gated Chest CT Xinran Gong, Gorkem Durak, Halil Ertugrul Aktas, Vedat Cicek, Jinkui Hao, Ulas Bagci, Nilay S. Shah, Bo Zhou Abstract Coronary artery calcium (CAC) scoring from chest CT is a well-established tool to stratify and refine clinical cardiovascular disease risk estimation. CAC quantification relies on the accurate delineation of calcified lesions, but is oftentimes affected by artifacts introduced by cardiac and respiratory motion. ECG-gated cardiac CTs substantially reduce motion artifacts, but their use in population screening and routine imaging remains limited due to gating requirements and lack of insurance coverage. Although identification of incidental CAC from non-gated chest CT is increasingly considered for it offers an accessible and widely available alternative, this modality is limited by more severe motion artifacts. We present ProDM (Property-aware Progressive Correction Diffusion Model), a generative diffusion framework that restores motion-free calcified lesions from non-gated CTs. ProDM introduces three key components: (1) a CAC motion simulation data engine that synthesizes realistic non-gated acquisitions with diverse motion trajectories directly from cardiac-gated CTs, enabling supervised training without paired data; (2) a property-aware learning strategy incorporating calcium-specific priors through a differentiable calcium consistency loss to preserve lesion integrity; and (3) a progressive correction scheme that reduces artifacts gradually across diffusion steps to enhance stability and calcium fidelity. Experiments on real patient datasets show that ProDM significantly improves CAC scoring accuracy, spatial lesion fidelity, and risk stratification performance compared with several baselines. A reader study on real non-gated scans further confirms that ProDM suppresses motion artifacts and improves clinical usability. These findings highlight the potential of progressive, property-aware frameworks for reliable CAC quantification from routine chest CT imaging. 1 Introduction Cardiovascular diseases (CVDs) remain one of the most prevalent and preventable causes of death globally, with an estimation of nearly 20 million fatalities worldwide in 2022 alone [ 40 ] . In the United States, CVDs are responsible for roughly every one in three mortalities [ 7 ] . Detection of coronary artery calcium (CAC) can help refine CVD risk estimation, enabling timely lifestyle modification and medical intervention [ 11 , 16 , 21 ] . CAC score is a highly specific marker of subclinical atherosclerosis and a powerful predictor of future cardiovascular events [ 16 , 4 , 28 ] . Compared to other methods of evaluating coronary artery disease and CVD risk, CAC scoring acquired through chest computed tomography (CT) is a non-invasive approach and offers a reliable, reproducible, and cost-effective method for assessing coronary plaque burden and providing risk stratification of the patient developing CVDs [ 14 ] . While ECG-gated cardiac CTs remain the gold standard for CAC scoring due to the ability to minimize motion artifacts, they are not routinely acquired in clinical practice due to the need for specialized imaging protocols involving ECG-gating [ 31 ] . Additionally, many insurance do not cover such scans as it is considered a screening rather than diagnostic procedure [ 1 , 17 ] . In contrast, non-gated chest CTs are far more commonly covered by insurance, and are frequently obtained for oncologic or pulmonary evaluation. Nearly twenty times more non-gated chest CTs are performed annually in the United States than gated cardiac CTs, and the ability to accurately assess incidental CAC on non-gated CT represents a major untapped opportunity for CVD prevention [ 12 ] . In fact, studies have found that CAC scores derived from non-gated scans strongly correlated with those acquired from gated scans, and incidental findings through non-gated scans are capable of predicting major adverse cardiac events in the future [ 36 , 2 , 44 , 23 , 39 ] . However, accurate cardiovascular risk stratification depends on the precise representation of both the spatial distribution and intensity of calcified lesions. The Agatston score, which is the most widely clinically used metric for CAC quantification, integrates both lesion area and peak intensity within predefined thresholds to quantify calcium burden. As a result, even subtle blurring or smearing, which are common in non-gated acquisitions, can lead to substantial deviations in Agatston scores, potentially impacting clinical usability and shifting patients across risk categories [ 3 , 5 , 35 ] . Consequently, despite their wide availability and potential as a substitute for gated scans, non-gated chest CTs remain limited by motion-induced degradation that undermines the accuracy of CAC quantification [ 30 ] . Compounding this challenge is the scarcity of paired datasets, as patients rarely undergo both ECG-gated cardiac CT and non-gated chest CT [ 10 ] , making it difficult to obtain matched motion-free and motion-corrupted images for supervised learning of a motion-correction model. Motion-compensated reconstruction (MCR) methods represent the classical efforts toward mitigating the effect of cardiac motion in CT. These techniques estimate local motion vectors fields from multi-phase or ECG-synchronized data and apply the estimated motion during reconstruction to compensate for cardiac motion [ 13 , 6 , 22 , 37 , 25 ] . While effective in reducing motion artifacts and improving image quality, they require projection data, ECG-gating, and multiple phase reconstructions, which are not readily available and not applicable to non-gated chest CT. More recently, many studies began adopting deep learning approaches to learn motion correction from the image domain directly. For example, [ 42 ] uses a VNet-based deep learning approach to perform centerline-based motion tracking and estimate the motion vector field from Coronary CT Angiography (CCTA) images. [ 15 ] proposed an attention-guided and spatial transformer–based framework that leverages cross-phase information for artifact correction, while [ 43 ] recently introduced a temporal-weighted motion correction network with a differentiable spatial transformer module trained on simulated motion data. These works primarily target gated-cardiac CT and CCTA, which already use ECG-gating and therefore exhibit smaller motion amplitudes, whereas motion in routine non-gated chest CTs is typically more severe. Generative diffusion-based models have also demonstrated promising results for motion artifact reduction in head CT [ 9 ] and MRI [ 27 , 33 ] , but to our best knowledge, no study has applied such diffusion-based approaches to coronary calcium motion correction with preservation of calcified lesion properties. To address the aforementioned challenges and gaps in research, we propose ProDM ( Pro perty-Aware Progressive Correction D iffusion M odel), a generative framework that restores motion-free coronary calcified lesions in non-gated chest CTs. Our main contributions are as follows: (1) Motion Simulation Engine for Supervised Learning We build a motion simulation data engine that generates large-scale, realistic paired datasets spanning diverse motion profiles, enabling supervised learning of motion artifact correction in non-gated chest CT scans. (2) CAC property-aware and score-driven learning. We introduce CAC property-aware supervision that explicitly preserves calcified lesion properties through a differentiable volumetric CAC score loss, which approximates the non-differentiable Agatston scoring process. (3) Progressive motion correction framework for non-gated chest CT. We developed a progressive motion correction framework that progressively removes motion artifacts and recovers the motion-free calcified lesions. This design enables stable and interpretable correction of motion artifacts in non-gated chest CTs, and is the first diffusion-based approach tailored for this task. 2 Methods In this section, we detail our proposed method, including simulating realistic CAC motion artifacts ( 2.1 ), the

Read the complete text