A Low Background Beta Detection System using a Time Projection Chamber
Rui-Yang Zhang, Zhi-Yong Zhang, Zeng-Xuan Huang, Yong Zhou, Jian-Bei Liu, Song-Song Tang, Yuan-Fei Cheng, Chang-Qing Feng, Ming Shao, Yi Zhou · 2025
Read A Low Background Beta Detection System using a Time Projection Chamber by Rui-Yang Zhang, Zhi-Yong Zhang, Zeng-Xuan Huang, Yong Zhou, Jian-Bei Liu, Song-Song Tang, Yuan-Fei Cheng, Chang-Qing Feng, Ming Shao, Yi Zhou (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-24837.txt.
Introduction
Ruiyang Zhang, Zhiyong Zhang, and co-authors describe their low background beta detection system, built around a time projection chamber designed to spot rare beta decays while rejecting background events. Sensitive rare-event searches need detectors that record particle tracks in detail and keep outside radiation from mimicking a signal. A time projection chamber images tracks in three dimensions, giving handles on event shape and origin.
Design choices aimed at low background operation are laid out for readers in particle instrumentation. Track information helps separate true beta events from noise and contamination. Such systems support experiments on nuclear and particle physics questions where signals are rare and backgrounds dominate the raw data.
Catalog record
| CREATOR | Rui-Yang Zhang, Zhi-Yong Zhang, Zeng-Xuan Huang, Yong Zhou, Jian-Bei Liu, Song-Song Tang, Yuan-Fei Cheng, Chang-Qing Feng, Ming Shao, Yi Zhou |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 41 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2512-24837
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A Low Background Beta Detection System using a Time Projection Chamber Rui-Yang Zhang, Zhi-Yong Zhang, Zeng-Xuan Huang, Yong Zhou, Jian-Bei Liu, Song-Song Tang, Yuan-Fei Cheng, Chang-Qing Feng, Ming Shao, Yi Zhou Abstract In this paper, we present a Time Projection Chamber (TPC) system for low-background beta radiation measurements. The system consists of a TPC with two-dimensional-strip readout Micromegas and an anti-coincidence detector with readout pads for cosmic ray veto. The detector system utilize an AGET-based waveform sampling system for data acquisition. The beta detection capability of the system was verified through experimental test using 90 Sr beta source. Additionally, a dedicated simulation program based on Geant4 was developed to model the entire detection process, including responses to both the beta source and background radiation. Simulation results were compared with experimental data for both beta and background samples, showing good agreements. The simulation samples were utilized to optimize and train classification models for beta and background discrimination. By applying the selected model into test data, the system achieved a background rate of 0.49 cpm / cm 2 0.49\text{\,}\mathrm{c}\mathrm{p}\mathrm{m}\mathrm{/}\mathrm{c}\mathrm{m}^{2} while retaining more than 55% of 90 Sr beta signals within a 7 cm 7\text{\,}\mathrm{c}\mathrm{m} diameter detection region. Further analysis revealed that approximately 70% of the background originates from environmental gamma radiation, while the remaining contribution mainly comes from intrinsic radioactivity of detector materials, particularly the FR-4 based field cage and readout plane. Based on the knowledge gained from the experiments and simulations, an optimization of the TPC system has been proposed, with simulation predicting a potential reduction of the background rate to 0.0012 cpm / cm 2 0.0012\text{\,}\mathrm{c}\mathrm{p}\mathrm{m}\mathrm{/}\mathrm{c}\mathrm{m}^{2} . I Introduction Since the discovery of alpha and beta radiation by Rutherford in 1899 RN27 , their properties have been extensively studied and widely utilized in nuclear physics experiments. Alpha and beta radiation are commonly found in the environment and are generally originated from natural and human produced radionuclides shahbazi2013review . In specific situations, it is crucial to monitor radiation levels to ensure they remain within safety standards reactors . For instance, measurements of 90 Sr radioactivity in environmental samples near the Fukushima Daiichi Nuclear Power Plant in 2013 provided insights into the nuclide’s mitigation following the nuclear accident RN61 . Similarly, radioactivity of alpha and beta emitting sources were monitored at Qinshan Nuclear Power Plant for a long period of time qinshan ; qinshan2 . In rare-event search experiments, alpha and beta radiation from uranium and thorium decay chains can significantly contribute to background signals formaggio2004backgrounds . Evaluating and suppressing these backgrounds is critical for achieving the desired sensitivity, as demonstrated in experiments like \chreplaced [id=rzhang]XENON aprile2011study , NEXT novella2019radiogenic and N \nu DEx nvdex XENON aprile2011study and NEXT novella2019radiogenic . Beyond nuclear and high-energy physics, alpha and beta radiation detection is also essential for monitoring pollution in drinking water and food water1 ; water2 ; food_review ; food1 ; food2 . In all these scenarios, accurately determining radiation levels is vital. However, radiation signals from samples are often accompanied by natural background radiation, necessitating the development of low-background detection techniques for precise measurements. The primary sources of background include environmental gamma rays, cosmic rays, and radioactive contamination in construction materials, with their contributions varying depending on the detection techniques and the type of radiation being measured background_source ; low_background_techniques . While several solutions exist in pursuing low-background radiation measurement jobbagy2010current , including commercially available detectors based on proportional counters or scintillators RN45 ; MPC9604 ; scint ; scint2 , these techniques rely primarily on counting rates and pulse height information to distinguish between different radiation types. This approach imposes limitations, particularly when detecting beta radiation, as its energy loss is similar to that of environmental background radiation. Consequently, these detectors lack the ability to actively separate beta signals from background noise, often requiring thick lead shielding layers (typically 10\text{\,}\mathrm{cm} ) to achieve low background rates. Such shielding materials restrict the detection volume and compromise system portability. To address these limitations, we propose using a Time Projection Chamber (TPC) as the foundational concept for low-background alpha and beta radiation detection RN37 . TPC offers the capability to simultaneously measure the 3D track and energy deposition of charged particles within the detector. By leveraging the detailed information provided by the incoming particles, it becomes possible to effectively discriminate target particles of interest from background signals. Furthermore, compared to traditional proportional counter-based techniques, TPC provides the additional advantage of event localization, enabling the determination of the spatial distribution of radiation within the sample. In our previous work RN37 , a Micromegas-based time projection chamber (TPC) prototype was developed for low-background alpha detection. The results demonstrated an alpha background rate of less than 1.6\text{\times}{10}^{-3}\text{\,}\mathrm{c}\mathrm{p}\mathrm{m} at a 95% confidence level without shielding, while achieving a 241 Am acceptance rate of 96%. \chadded [id=rzhang]The excellent performance in alpha particle detection highlights the potential of TPC technology for low-background radiation detection screener3D ; alphaTPC . Building on this success, we have developed a new TPC system aimed at low-background beta radiation detection. Unlike alpha particles, beta particles have significantly weaker ionization power, resulting in longer track lengths siegbahn2012alpha . Furthermore, beta detection is subject to additional background sources, such as cosmic rays and environmental gamma radiation. To address these challenges, we optimized the TPC system design to improve its sensitivity and discrimination capabilities. A dedicated simulation program was established to model the detector response, providing insights into its performance and the separation of beta signals from background events. In this paper, we present the design, fabrication, simulation, and test results of the TPC prototype for beta radiation detection in Section II – V . The beta detection background origins were investigated in Section VI using both experimental data and simulation results. Finally, further optimizations of the detector are discussed in Section VII , with simulations predicting an anticipated reduction in the background rate. II Detector structure The new TPC prototype builds upon experience gained from the previous version and is optimized to achieve a larger detection area while effectively suppressing background in beta radiation detection. The system consists of two sub-detectors assembled back-to-back: a TPC detector and an anti-coincidence detector, as shown in Figure 1 . The TPC detector serves as the primary detection element for beta particles, while the anti-coincidence detector is employed to veto cosmic ray background. The drift lengths of the TPC detector and the anti-coincidence detector are 55\text{\,}\mathrm{mm} and 8\text{\,}\mathrm{mm} , respectively. For clarity, the term “TPC” will refer to the TPC detector alone, while “TPC system” will refer to the entire combined detection system hereafter. Figure 1: Schematic lay-out (left) and the mechanical drawing (right) of the TPC system. Thermal-bonded Micromegas RN31 ; RN32 is used both as the readout plane of the TPC and as the anti-coincidence detector. The core component of Micromegas comprises a stainless-steel mesh bonded to a printed circuit board (PCB) with thermal bonding adhesive, forming a 100\text{\,}\mathrm{\SIUnitSymbolMicro m} amplification gap. The readout electrodes of the two detectors are situated on opposite sides of the PCB. The PCB is a 10-layer board with a thickness of 2.3\text{\,}\mathrm{mm} , sufficient to block beta particles with energies below 5\text{\,}\mathrm{M}\mathrm{e}\mathrm{V} from reaching the anti-coincidence detector. To provide discharge protection, a germanium layer