Nine years of UVIT: assessing sensitivity variation Facilities: UVIT, Gaia , SIMBAD Aafitrans ( 22 ; 7 ) ; Astrometry.net ( 25 ) ; Astropy ( 5 ; 3 ; 4 ) ; Curvit ( 21 ) ; Jupyter ( 24 ) ; Matplotlib ( 20 ) ; Numpy ( 18 ) ; Pandas ( 27 ) ; Photutils ( 8 ) ; SaoImageDS9 ( 23 ) ; Scipy ( 36 ) ; Spyder

Akanksha Dagore, Prajwel Joseph, S.N. Tandon, Annapurni Subramaniam, S.K. Ghosh, C.S. Stalin · 2025

Read Nine years of UVIT: assessing sensitivity variation Facilities: UVIT, Gaia , SIMBAD Aafitrans ( 22 ; 7 ) ; Astrometry.net ( 25 ) ; Astropy ( 5 ; 3 ; 4 ) ; Curvit ( 21 ) ; Jupyter ( 24 ) ; Matplotlib ( 20 ) ; Numpy ( 18 ) ; Pandas ( 27 ) ; Photutils ( 8 ) ; SaoImageDS9 ( 23 ) ; Scipy ( 36 ) ; Spyder by Akanksha Dagore, Prajwel Joseph, S.N. Tandon, Annapurni Subramaniam, S.K. Ghosh, C.S. Stalin (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-24475.txt.

Introduction

Akanksha Dagore and five colleagues check whether a space telescope's eye has dimmed with age. The Ultra-Violet Imaging Telescope flies on AstroSat, India's first multiwavelength observatory. It launched in September 2015. The telescope images in far- and near-ultraviolet light at once. Its near-ultraviolet channel failed in 2018. Contamination might slowly dull the far-ultraviolet optics.

Nine years of calibration data test that worry. Two steady targets anchor the check: the open cluster NGC 188 and the white dwarf HZ 4. Their far-ultraviolet brightness was tracked across the mission. No significant sensitivity loss appears over the nine years. No unexplained episodic dips appear either. The far-ultraviolet channel remains as sensitive as at launch. Long-lived ultraviolet astronomy from AstroSat rests on firm ground.

Catalog record

CREATORAkanksha Dagore, Prajwel Joseph, S.N. Tandon, Annapurni Subramaniam, S.K. Ghosh, C.S. Stalin
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE49 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2512-24475

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Nine years of UVIT: assessing sensitivity variation Facilities: UVIT, Gaia , SIMBAD Aafitrans ( 22 ; 7 ) ; Astrometry.net ( 25 ) ; Astropy ( 5 ; 3 ; 4 ) ; Curvit ( 21 ) ; Jupyter ( 24 ) ; Matplotlib ( 20 ) ; Numpy ( 18 ) ; Pandas ( 27 ) ; Photutils ( 8 ) ; SaoImageDS9 ( 23 ) ; Scipy ( 36 ) ; Spyder ( 29 ) ; Topcat ( 35 ) Akanksha Dagore, Prajwel Joseph, S.N. Tandon, Annapurni Subramaniam, S.K. Ghosh, C.S. Stalin Abstract The Ultra-Violet Imaging Telescope (UVIT) is one of the five payloads onboard the first Indian multiwavelength astronomical observatory, AstroSat , launched by the Indian Space Research Organisation on 28 September 2015. UVIT, designed for simultaneous imaging in the far-ultraviolet (FUV; 1300 − - 1800 Å) and near-ultraviolet (NUV; 2000 − - 3000 Å) channels, has completed nine years in orbit in 2024 despite the failure of the NUV channel in 2018. As the FUV optics is subject to possible reduction in sensitivity due to microscopic amounts of contaminants, we used the FUV data acquired by UVIT over the past nine years on the open cluster NGC 188 and the white dwarf HZ 4 to study sensitivity variations in the UVIT FUV channel. Our findings indicate no significant reduction in the sensitivity of the FUV channel over the last nine years, with no significant episodic variations due to unknown causes. show][email protected] I Introduction The Ultra-Violet Imaging Telescope (UVIT) is one of the five payloads onboard AstroSat ( 30 ; 1 ) , India’s first space observatory targeted towards carrying out simultaneous multi-wavelength observations launched on 28 September 2015. AstroSat is capable of observing in the ultraviolet (UV), visible (VIS), and X-ray spectral bands with the help of its five scientific payloads, namely UVIT, the Soft X-ray imaging Telescope (SXT), the Large Area X-ray Proportional Counter (LAXPC), the Cadmium Zinc Telluride Imager (CZTI), and the Scanning Sky Monitor (SSM). While the other four payloads observe in the X-ray window, UVIT performs simultaneous observations for a given region of the sky in far-ultraviolet (FUV; 1300 - 1800 Å), near-ultraviolet (NUV; 2000 - 3000 Å) and VIS (3200 - 5500 Å) channels. UVIT consists of twin Ritchey-Chr \acute{\mathrm{e}} tian telescopes, each with a primary and a secondary mirror of \sim 375 mm and \sim 140 mm diameter, respectively, along with a channel-filter configuration and a detector system. Each channel is equipped with a set of filters to select a narrower band-pass in which the intensified imaging detectors can operate in two distinct modes, namely high-gain photon counting (PC) mode and low-gain integration (INT) mode. The FUV and NUV channels perform observations in the photon counting mode, with a frame rate of \sim 29 frames per second. The VIS channel, on the other hand, works in the low-gain integration mode, which gives out a reduced frame rate ( \sim 1 frame per second). The VIS channel is used to estimate the spacecraft pointing drift ( 15 ) . For the two UV channels, UVIT has a spatial resolution of \sim$$ FWHM and a field of view of \sim$$ diameter. The C-MOS imagers of the detectors have a size of 512\times 512 pixels. Observations can also be carried out in already-defined, narrower window settings at faster frame rates. The expected mission duration for AstroSat was planned to be five years ( 30 ) ; however, as of September 2024, AstroSat has completed nine years in orbit. The UVIT NUV channel became non-operational during this period on 30 March 2018. Despite the failure of the NUV channel, the FUV and VIS channels continue to function as intended. However, given its time in orbit, there exists a possibility that UVIT could have experienced a reduction in sensitivity. Possible factors can include degradation of reflectivity due to atomic oxygen ( 6 ) , chemical contamination of the optical surfaces due to charged particles and UV radiation assisted reactions ( 26 ) , and accumulation of space dust and debris ( 14 ) . Therefore, all these issues raise a need to investigate for any sensitivity degradation in UVIT. In a previous study, 33 found no significant degradation in the sensitivity of the FUV and NUV channels of UVIT, using stars in open cluster NGC 188 observations between 31 December 2015 and 23 October 2018. Since then, several years have passed, highlighting the need for new analysis. With the NUV channel non-functional since 2018, only the FUV channel requires sensitivity checks. To assess potential sensitivity variations in the FUV channel, frequent observations of a stable source spanning the lifetime of UVIT are necessary. The requirement of stability is obviously fulfilled by the white dwarf HZ 4, which is the calibration source for photometry with UVIT. However, unlike NGC 188, HZ 4 is not available for observation for all months of the year. Therefore, we use frequent observations of NGC 188 to monitor any significant variations, such as > 5 per cent, on timescales of a few months, and infrequent observations of HZ 4 to monitor long-term decline at levels of one per cent. By comparing flux measurements of this source at various epochs, we can identify any changes in the FUV channel’s sensitivity over time. UVIT captured its first sky image on 30 November 2015 of the open cluster NGC 188 ( \alpha=00h\ 47m\ 11.5s , \delta = [formula] [formula] [formula] ) 1 1 1 https://simbad.u-strasbg.fr/simbad/sim-basic?Ident=NGC+188 ( 15 ) , which has been monitored ever since for the telescope’s calibration and sensitivity studies, including the current one. NGC 188 observations are also conducted to test UVIT’s functionality after performing mitigation operations to resolve instrument problems. Furthermore, these observations have contributed to scientific studies ( 32 ; 28 ) . Fig. 1 illustrates a pseudo-colour image of the NGC 188 field created from the FUV F148W and NUV N279N filters of UVIT. While three FUV-bright sources are visible in Fig. 1 , the brightest source suffers from saturation effects, and the other two were found to be variable during the course of this work. Nevertheless, this calibration source provides data to monitor any decline in sensitivity at levels below 1% over long periods of years. Figure 1 : A pseudo-colour image of the NGC 188 field. The blue and yellow colours represent the observations conducted in the UVIT’s FUV F148W (exposure time = 36484 seconds) and NUV N279N (exposure time = 14954 seconds) filters, respectively. The image has been processed to bring out the faint features. Section 2 discusses the characteristics of the observational data used for the analysis. The data reduction methodology is explained in Section 3. The analysis and results are given in Section 4. Lastly, the conclusion is reported in Section 5. II Observational Data The UVIT observations are planned to coincide with the orbital phase of the satellite that falls within the Earth’s shadow, which blocks direct exposure from the Sun to prevent instrument damage. AstroSat covers a complete orbit around the Earth in \sim 100 minutes, and any uninterrupted imaging session during this phase with a specific filter-window configuration is termed an episode . The observational data for HZ 4 and

Read the complete text