First Positronium Lifetime Imaging using 52 Mn and 55 Co with a plastic-based PET scanner

Manish Das, Sushil Sharma, Ermias Yitayew Beyene, Aleksander Bilewicz, Jarosław Choiński, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Jakub Hajduga, Sharareh Jalali, Krzysztof Kacprzak, Tevfik Kaplanoglu, Łukasz Kapłon, Kamila Kasperska, Aleksander Khreptak, Grzegorz Korcyl, Tomasz Kozik, Karol K · 2025

Read First Positronium Lifetime Imaging using 52 Mn and 55 Co with a plastic-based PET scanner by Manish Das, Sushil Sharma, Ermias Yitayew Beyene, Aleksander Bilewicz, Jarosław Choiński, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Jakub Hajduga, Sharareh Jalali, Krzysztof Kacprzak, Tevfik Kaplanoglu, Łukasz Kapłon, Kamila Kasperska, Aleksander Khreptak, Grzegorz Korcyl, Tomasz Kozik, Karol K (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-24261.txt.

Introduction

Manish Das and a large team report first positronium lifetime imaging with two unusual isotopes. The imaging extends standard PET scanning. Positronium atoms form in tissue before annihilating. Their lifetime probes the tissue's molecular architecture. The scanner used is the plastic-based modular J-PET. The isotopes are manganese-52 and cobalt-55.

Four samples were studied in each run. Two were certified reference materials, polycarbonate and fused silica. Two were human tissues, cardiac myxoma and fat. Events were selected by triple coincidence of two annihilation photons and one prompt gamma. Lifetimes in polycarbonate matched certified values for both isotopes. Cobalt-55 gave cleaner spectra with better peak-to-background ratios. Manganese-52 offers a longer half-life but more background. The study shows complex decay schemes still allow lifetime imaging.

Catalog record

CREATORManish Das, Sushil Sharma, Ermias Yitayew Beyene, Aleksander Bilewicz, Jarosław Choiński, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Jakub Hajduga, Sharareh Jalali, Krzysztof Kacprzak, Tevfik Kaplanoglu, Łukasz Kapłon, Kamila Kasperska, Aleksander Khreptak, Grzegorz Korcyl, Tomasz Kozik, Karol K
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE66 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2512-24261

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

First Positronium Lifetime Imaging using 52 Mn and 55 Co with a plastic-based PET scanner Manish Das, Sushil Sharma, Ermias Yitayew Beyene, Aleksander Bilewicz, Jarosław Choiński, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Jakub Hajduga, Sharareh Jalali, Krzysztof Kacprzak, Tevfik Kaplanoglu, Łukasz Kapłon, Kamila Kasperska, Aleksander Khreptak, Grzegorz Korcyl, Tomasz Kozik, Karol Kubat, Deepak Kumar, Sumit Kumar Kundu, Anoop Kunimmal Venadan, Edward Lisowski, Filip Lisowski, Justyna Medrala-Sowa, Simbarashe Moyo, Wiktor Mryka, Szymon Niedźwiecki, Anand Pandey, Piyush Pandey, Szymon Parzych, Alessio Porcelli, Bartłomiej Rachwał, Martin Rädler, Narendra Rathod, Noman Razzaq, Axel Rominger, Kuangyu Shi, Magdalena Skurzok, Maciej Słotwiński, Anna Stolarz, Tomasz Szumlak, Pooja Tanty, Keyvan Tayefi Ardebili, Satyam Tiwari, Kavya Valsan Eliyan, Rafał Walczak, Ewa Ł. Stepień, Paweł Moskal Abstract This study demonstrates applicability of 52 Mn and 55 Co radionuclides for positronium imaging. Positronium Lifetime Imaging (PLI) extends positron emission tomography by using the lifetime of positronium atoms as a probe of tissue molecular architecture. However, its practical use requires β + \beta^{+} emitters that also provide an additional prompt γ \gamma ray to mark the positron creation time. In this work, we report the first PLI measurements performed with 52 Mn and 55 Co using the modular J-PET. Four samples were studied in each experiment: two Certified Reference Materials (polycarbonate and fused silica) and two human tissues (cardiac myxoma and adipose). The selection of PLI events was based on the registration of two 511 keV annihilation photons and one prompt gamma in triple coincidence. From the resulting lifetime spectra we extracted the mean ortho-positronium lifetime τ oPs \tau_{\text{oPs}} and the mean positron lifetime Δ ​ T mean \Delta T_{\text{mean}} for each sample. The measured values of τ oPs \tau_{\text{oPs}} in polycarbonate using both isotopes matches well with the certified reference values. Furthermore, 55 Co reproduced identical results for fused-silica measurements at their respective uncertainty levels. In contrast, measurements with 52 Mn in fused silica show a minor deviation, which could be caused by the Parafilm spacer. In myxoma and adipose tissue, the reduced τ oPs \tau_{\text{oPs}} values are mainly linked to the long storage history of the samples rather than to the choice of isotope. Comparing peak-to-background ratios and spectral purity, 55 Co provides cleaner PLI data under the same experimental conditions. Although 52 Mn offers a longer half-life and a multi gamma cascade enhancing β + \beta^{+} + γ \gamma coincidences, but at the expense of higher background. In this study, we demonstrate that the applied selection criteria on the data measured with the modular J-PET can be used for PLI studies even with radionuclides with complex decay patterns. keywords PLI, Positronium, J-PET Introduction Positron Emission Tomography (PET) is a well established medical modality for tracing and mapping metabolic activity in-vivo within the human body. In a PET scan, a positron-emitting radiotracer is administered intravenously. The emitted positron annihilates with surrounding electrons, which produces a pair of 511-keV photons emitting in nearly opposite directions. Registering both photons in a coincident window defines the Line Of Response (LOR), and intersection of LORs acquired from the full scan are used to reconstruct the spatial map of annihilations sites. This technique enables the acquisition of precise non-invasive images of biological processes on a molecular scale [ 68 , 2 ] . The conventional PET method quantifies tracer uptake values, but does not directly provide information about the tissue microenvironment. Positronium imaging, an emerging extension of PET, complements the use of conventional PET [ 55 , 57 , 51 , 48 , 59 ] . During PET, in nearly 40% of cases, a metastable bound state known as the positronium atom (Ps) is formed within the human body. This previously underexplored phenomenon can be measured and characterized in-vivo [ 56 ] , enabling Positronium Lifetime Imaging (PLI) as a microenvironment sensitive extension of PET. Ps is formed when a positron from a radiotracer binds with an electron from a nearby molecule. It can be formed in either of the two spin configurations: para-positronium (pPs), a short-lived state with a mean lifetime of 125 ps and ortho-positronium (oPs), a significantly longer lived state with mean lifetime of about 142 ns in vacuum [ 4 ] .The oPs experiences a substantial decrease in its mean lifetime when it interacts with biological molecules in tissue environment [ 1 , 59 , 33 , 7 , 31 , 91 , 35 , 60 , 63 ] . Where positron can picks-off an electron from surrounding molecules, annihilating mainly into two photons [ 4 , 32 ] . Therefore, pick-off rate depends on the electron density and size of the cavity making the oPs mean lifetime a sensitive probe of nanoscale free-volume structure. Another important factor is the oxygen concentation in the tissues which can further reduce the mean lifetime [ 74 , 81 ] . Oxygen molecules are paramagnetic in nature and during collision with oPs, they induce conversion from oPs to pPs. The third process is the oxidation which refers to the chemical quenching of oPs via electron transfer to different reactive species (e.g., free radicals, certain biomolecules, oxidants), forming the transient chemical complexes with much shorter lifetimes [ 4 , 20 ] . Consequently, measuring the mean lifetime of oPs in biological tissues allows for a direct and quantitative measure to study the contrast of tissue microenvironment and hypoxia [ 74 , 81 , 54 ] . This makes Ps lifetime imaging (PLI) a promising biomarker for tissue structure analysis for disease characterization. The technique has become widely recognized and has stimulated a significant interest in the implementation of PLI in clinical PET scans. This has led to new development in both clinical and preclinical scanners worldwide [ 56 , 59 , 28 , 80 , 47 , 69 , 10 , 24 , 36 , 25 , 72 , 83 , 84 , 46 ] . However, the selection of a suitable radionuclide remains the main challenge limiting PLI’s clinical applications [ 12 , 57 ] . The ideal radioisotope needs to produce an additional prompt gamma emitted immediately after positron emission. In PLI, the registration time of the prompt gamma is used as a precise timestamp of positron creation, which serves as the start time for the positronium lifetime measurement. Subsequently, detection of the annihilation photons from direct annihilation of the positron with surrounding electrons or through the formation of the Ps atom allows measurement of the positron lifetime. For practical reasons, the radioisotope for clinical PLI should meet additional criteria, which include a high branching ratio for \beta^{+}+\gamma emission, a half-life compatible with PET scans, and manufacturing via standard protocols [ 78 , 12 , 57 ] . The proof of concept for positronium lifetime imaging in biological tissue was demonstrated by the J-PET collaboration, which performed the first ex-vivo PLI experiment using the J-PET tomograph [ 59 ] . In this study, 22 Na was used as the positron source, well suited for ex-vivo PLI emitting a 1275 keV prompt gamma in 99.94% of \beta^{+} decays. For this study, special phantoms were prepared with different biological tissues (cardiac myxoma, adipose) excised from two different patients. In each phantom, a 22 Na source was sandwiched between tissues samples. All phantoms were then

Read the complete text