Asymmetry effects in homodyne and heterodyne measurements: Positive operator-valued measures and asymptotic security of Gaussian continuous variable quantum key distribution
A. S. Naumchik, Roman K. Goncharov, Alexei D. Kiselev · 2025
Read Asymmetry effects in homodyne and heterodyne measurements: Positive operator-valued measures and asymptotic security of Gaussian continuous variable quantum key distribution by A. S. Naumchik, Roman K. Goncharov, Alexei D. Kiselev (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-22591.txt.
Introduction
A. S. Naumchik, Roman K. Goncharov, and Alexei D. Kiselev examine how imperfect detectors distort quantum key distribution, the technique that uses quantum states to share secret keys. Real homodyne and heterodyne readings suffer asymmetry: beam splitters are uneven and detectors differ in efficiency. Working in a Gaussian approximation for light-count stats, the authors compute the measurement operators, the POVMs, that honestly include those flaws.
For heterodyne detection, the ideal measurement must be written with projectors onto squeezed states, and the form is not unique; the squeezing parameter becomes an extra knob affecting the eavesdropper's information. They then analyze long-run security of the Gaussian-modulated continuous-variable protocol when an attacker controls the measurement noise. Mutual information, Holevo information, and the secret fraction all degrade under asymmetry.
Catalog record
| CREATOR | A. S. Naumchik, Roman K. Goncharov, Alexei D. Kiselev |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 84 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2512-22591
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Asymmetry effects in homodyne and heterodyne measurements: Positive operator-valued measures and asymptotic security of Gaussian continuous variable quantum key distribution A. S. Naumchik, Roman K. Goncharov, Alexei D. Kiselev Abstract We use the Gaussian approximation describing photocount statistics for both the homodyne and the double homodyne (heterodyne) measurements to study asymmetry effects arising from imbalance of the beam splitters and variations in quantum efficiencies of the photodetectors. After computing the Q Q symbols of the positive operator-valued measures (POVMs) of noisy measurements that take into account the asymmetry effects, the operator representations for the POVMs are obtained in the form that assumes applying the additive noise quantum channel to the POVMs of noiseless (ideal) measurements. For double homodyne detection, it was found that the noiseless measurements should generally be expressed in terms of the projectors onto squeezed-states and the corresponding squeezed-state operator representation of POVM along with the measurement noise channel depend on the squeezing parameter that lies in the interval dictated by the condition for the excess noise covariance matrix to be positive semi-definite. The analytical results are used to perform analysis of the asymptotic security of the Gaussian-modulated continuous variable quantum key distribution (CV-QKD) protocol in the untrusted-noise scenario where the measurement noise is assumed to be accessible to an adversary. The inherent non-uniqueness of the operator representation for the double-homodyne POVM manifests itself in the squeezing dependent Holevo information that needs to be additionally optimized. For both types of the measurements, the mutual information, the Holevo information and the asymptotic secret fraction are sensitive to asymmetry effects leading to degraded performance of the protocol. I Introduction Optical homodyne detection is a well-established experimental technique of quantum optics for measuring phase-sensitive properties of light fields. In a typical four-port homodyne setup described in textbooks (see, e.g., the textbook Vogel and Welsch 2006 ), a weak quantum signal is superimposed with a strong local oscillator (LO) at a beam splitter and the resulting output fields are detected with photodiodes, so that information about the properties of the signal field quadratures is extracted from the statistics of the difference photocurrent. In the realm of continuous-variable (CV) quantum systems, this technique plays a key role of fundamentally important measurement method and, over the course of the last two decades of the past century, the homodyne-based measurement schemes have been the subject of numerous theoretical studies Yuen and Shapiro 1978 ; Shapiro et al. 1979 ; Yuen and Shapiro 1980 ; Yuen and Chan 1983 ; Walker 1987 ; Collett et al. 1987 ; Braunstein 1990 ; Vogel and Grabow 1993 ; Leonhardt and Paul 1993 ; Ban 1997 ; Banaszek and Wódkiewicz 1997 ; Kuzmich et al. 1998 ; Feng et al. 2016 reviewed in Welsch et al. 1999 . In the limit of strong local oscillator, the noiseless homodyne detection becomes a projective measurement described by projectors onto a suitable set of quadrature eigenstates, whereas similar result for the eight-port double homodyne scheme, which is known to be equivalent to the so-called heterodyne detection scheme, is represented by the coherent states. In this case, homodyne and double homodyne (heterodyne) schemes can be regarded as implementations of Gaussian measurements defined as measurement procedures that produce a Gaussian probability distribution of outcomes for any Gaussian state Giedke and Ignacio Cirac 2002 ; Fiurášek and Mišta 2007 (see also the monograph Serafini 2023 ). Note that the LO intensity and fluctuations induced effects emerging beyond the strong LO approximation are studied in Refs. Vogel 1995 ; Cives-Esclop et al. 2000 ; Auyuanet et al. 2019 ; Olivares et al. 2020 ; Thekkadath et al. 2020 . A wide variety of technologically important applications, where the homodyne related techniques are of crucial importance, include the quantum tomography of CV states Leonhardt 1997 ; Smithey et al. 1993 ; Kühn et al. 1995 ; D’Auria et al. 2009 ; Lvovsky and Raymer 2009 ; Buono et al. 2010 ; Teo et al. 2017 ; Tiunov et al. 2020 ; Olivares et al. 2019 ; Qi et al. 2020 ; Kumar and Arvind 2022 ; Oh et al. 2019 and the quantum communication protocols Braunstein and van Loock 2005 ; Semenov et al. 2012 such as the CV quantum teleportation Furusawa et al. 1998 ; Shi et al. 2023 and the continuous-variable quantum key distribution (CV-QKD) systems Grosshans and Grangier 2002a ; Weedbrook et al. 2004a ; Weedbrook et al. 2012 ; Zhang et al. 2024 . Practical security for real-world QKD systems requires the deviations between the system and the ideal to be assessed so as to take into account imperfections of devices Scarani et al. 2009 ; Xu et al. 2020 . Imperfections of the photodetectors such as non-unity detector efficiencies, electronic noise, dark counts, finite bandwidth and photon-number resolution, detector dead times and afterpulses introduce excess noise that affects CV-QKD security Chi et al. 2011 ; Jouguet et al. 2012 ; Wang et al. 2019 ; Lupo and Ouyang 2022 ; Semenov et al. 2024 ; Hajomer et al. 2025 ; Oruganti et al. 2025 . Noisy homodyne and heterodyne measurements are no longer projective and has to be analyzed in terms of the positive operators-valued measures (POVMs). Imperfections leading to the measurement noise may open side channels exploitable by an adversary using either wavelength-dependent or detector-blinding attacks Huang et al. 2012 ; Huang et al. 2014 ; Qin et al. 2018 ; Qin et al. 2016 . Countermeasures to such attacks include spectral filtering, detector balancing, and careful calibration of the photodetectors Zou et al. 2022 ; Wang et al. 2023 ; Pan et al. 2025 . In this paper, we focus our attention on the quantum measurement imperfections that will be collectively referred to as the asymmetry effects . These effects arise from the unbalanced beam splitters and difference in quantum efficiencies of the photodetectors. Though in recent studies Barchielli and Santamato 2022 ; Ruiz-Chamorro et al. 2023a ; Bartlett et al. 2025 , the asymmetry effects are found to be of importance for quantum random number generators Barchielli and Santamato 2022 and security analysis of CV-QKD Ruiz-Chamorro et al. 2023a ; Bartlett et al. 2025 , a systematic POVM-based theoretical analysis has not yet been received proper attention. Our goal is to fill the gap. To this end, we derive the POVMs and and study how the asymmetry effects influence the asymptotic security of the Gaussian CV-QKD protocol in the untrusted-noise scenario where an adversary controls measurement imperfections. The paper is organized as follows. In Sec. II , we obtain the statistical distribution of difference photon counts with the asymmetry effects taken into account and apply the Gaussian approximation to deduce the Q symbol of the corresponding homodyne POVM. The general strategy described in Sec. II.2 is employed to deduce the operator representation for the POVM. In Sec. III , the eight-port double-homodyne scheme is analyzed using the method presented in the previous section. After deriving the Q symbol of POVM in the Gaussian approximation, we show that the operator representation of the POVM can be obtained by applying the additive noise channel with the squeezing dependent excess noise covariance matrix to the noiseless squeezed-state measurements. Thus, it turned out