Smart IoT-Based Leak Forecasting and Detection for Energy-Efficient Liquid Cooling in AI Data Centers

Krishna Chaitanya Sunkara, Rambabu Konakanchi · 2025

Read Smart IoT-Based Leak Forecasting and Detection for Energy-Efficient Liquid Cooling in AI Data Centers by Krishna Chaitanya Sunkara, Rambabu Konakanchi (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-21801.txt.

Introduction

Krishna Chaitanya Sunkara and Rambabu Konakanchi build a monitoring system that forecasts coolant leaks in liquid-cooled AI data centers before they force shutdowns. Liquid cooling handles the extreme heat of graphics-processor clusters, but a leak wastes energy through unplanned downtime and long repairs.

Their proof-of-concept system pairs two machine learning components fed by Internet-of-Things sensors. An LSTM network forecasts leaks probabilistically, while a random forest classifier detects sudden events instantly. On synthetic data built to ASHRAE 2021 standards, detection accuracy reached about ninety-six percent and forecasting about eighty-seven percent within half-hour windows. Humidity, pressure, and flow rate carried the strongest warning signals; temperature lagged because of thermal inertia. The system streams data over MQTT into InfluxDB with live dashboards, warning two to four hours ahead. For a typical facility, the authors estimate meaningful annual energy savings.

Catalog record

CREATORKrishna Chaitanya Sunkara, Rambabu Konakanchi
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE22 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2512-21801

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Smart IoT-Based Leak Forecasting and Detection for Energy-Efficient Liquid Cooling in AI Data Centers Krishna Chaitanya Sunkara, Rambabu Konakanchi Abstract AI data centers which are GPU centric, have adopted liquid cooling to handle extreme heat loads, but coolant leaks result in substantial energy loss through unplanned shutdowns and extended repair periods. We present a proof-of-concept smart IoT monitoring system combining LSTM neural networks for probabilistic leak forecasting with Random Forest classifiers for instant detection. Testing on synthetic data aligned with ASHRAE 2021 standards, our approach achieves 96.5% detection accuracy and 87% forecasting accuracy at 90% probability within ± \pm 30-minute windows. Analysis demonstrates that humidity, pressure, and flow rate deliver strong predictive signals, while temperature exhibits minimal immediate response due to thermal inertia in server hardware. The system employs MQTT streaming, InfluxDB storage, and Streamlit dashboards, forecasting leaks 2-4 hours ahead while identifying sudden events within 1 minute. For a typical 47-rack facility, this approach could prevent roughly 1,500 kWh annual energy waste through proactive maintenance rather than reactive emergency procedures. While validation remains synthetic-only, results establish feasibility for future operational deployment in sustainable data center operations. I Introduction Modern GPU data centers require liquid cooling to manage thermal loads beyond air cooling capabilities [ 1 ] . Direct-to-chip cold plates offer superior thermal transfer but create leak risks causing equipment failures and energy waste. The 2019 Google Paris incident demonstrated these risks when cooling system failure flooded infrastructure and ignited fires, disrupting continental services [ 2 ] . Similar events at Meta facilities underscore industry-wide vulnerability [ 3 ] . Existing methods, containment trays, moisture sensors, threshold monitoring, respond only after leaks occur and damage begins. Predictive maintenance techniques reducing utility equipment failures by 50% [ 4 , 5 ] can apply to cooling infrastructure. Our approach uses machine learning to identify precursor patterns in sensor data, forecasting leaks before occurrence. We combine LSTM networks for probabilistic time-horizon prediction with Random Forest classifiers for immediate detection, implemented through MQTT streaming [ 13 ] , InfluxDB storage [ 15 ] , and Streamlit visualization. This proof-of-concept validation uses synthetic data representing 7 days of minute-resolution monitoring from four IoT sensors in rack enclosures, with cold plate leak scenarios matching ASHRAE 2021 specifications [ 16 ] . Key contributions: (1) probabilistic LSTM forecasting validated within \pm 30-minute windows, (2) 96.5% F1-score RF detection, (3) integrated smart IoT architecture design, (4) thermal inertia insights and energy savings quantification for sustainable operations. We acknowledge this work represents a feasibility study requiring empirical validation before operational deployment. II Related Work Physical leak detection relies on hardware sensors. TTK and Sensaphone systems locate moisture but cannot predict failures [ 6 , 7 ] . Machine learning shows promise: Random Forest achieved 96% accuracy on irrigation leak detection from pressure signatures [ 8 ] , CNNs identified water pipe leaks through acoustic analysis [ 9 ] . LSTM autoencoders reached 97-100% sensitivity in distribution networks by modeling normal behavior [ 10 ] . RUL forecasting for industrial equipment [ 11 ] provides precedent for our coolant system application. IoT monitoring leverages MQTT’s lightweight architecture and low latency [ 13 ] . Manufacturing facilities use MQTT streaming for equipment fault detection [ 14 ] . InfluxDB optimizes high-volume timestamped data handling [ 15 ] . However, prior work hasn’t integrated probabilistic time-to-event forecasting with real-time classification for liquid-cooled facilities while quantifying energy efficiency gains. Deep learning approaches have demonstrated effectiveness in anomaly detection for critical infrastructure monitoring. Recurrent architectures excel at capturing temporal dependencies in multivariate sensor streams, enabling early warning systems before catastrophic failures occur. Time-series forecasting using sequence-to-sequence models has shown particular promise for systems with gradual degradation patterns, where subtle precursor signals emerge hours before actual failures. However, these approaches typically focus on binary classification or point-in-time predictions rather than probabilistic time-to-event forecasting that provides actionable maintenance windows. The challenge lies in calibrating prediction confidence intervals to balance early warning time against false alarm rates in operational environments. Data center cooling systems present unique challenges for predictive maintenance due to their mission-critical nature and complex failure modes. Traditional approaches rely on threshold-based alerting with fixed parameter bounds, leading to high false positive rates from normal operational variance or delayed detection when degradation occurs gradually within nominal ranges. While BMS and DCIM platforms collect extensive telemetry, they primarily serve reactive monitoring rather than predictive analytics. Recent work in HVAC fault detection [ 12 ] demonstrates the value of model-based approaches, but direct-to-chip liquid cooling introduces distinct physics with rapid failure propagation requiring sub-minute detection latency. The integration of edge computing capabilities with cloud-based training pipelines remains an open research area for enabling real-time inference while maintaining model currency through continuous learning from operational data. IoT monitoring leverages MQTT’s lightweight architecture and low latency [ 13 ] . Manufacturing facilities use MQTT streaming for equipment fault detection [ 14 ] . InfluxDB optimizes high-volume timestamped data handling [ 15 ] . However, prior work hasn’t integrated probabilistic time-to-event forecasting with real-time classification for liquid-cooled facilities while quantifying energy efficiency gains. III System Architecture and Methodology Fig. 1: System architecture showing data flow from IoT sensors in rack enclosures through MQTT broker and InfluxDB storage to dual ML models (LSTM forecasting and Random Forest detection) with Streamlit dashboard for real-time monitoring and alerts. Our four-layer system simulates direct-to-chip cold plate scenarios per ASHRAE 2021 specifications [ 16 ] : coolant loop pressure (0.7-2.5 bar [ 17 ] ), cold plate flow rate (2-5 L/min [ 18 ] ), rack enclosure ambient humidity (40-60% RH [ 16 ] ), and enclosure temperature (18-27 ∘ C [ 16 ] ). Normal operation uses Gaussian-distributed minute-resolution parameters: pressure 2.0 \pm 0.05 bar, flow 1.5 \pm 0.03 L/min, humidity 50 \pm 2% RH, temperature 25 \pm 0.3 ∘ C, matching major facility operations [ 19 ] . Cold plate leak events (5% occurrence) follow documented patterns [ 16 , 20 ] : coolant pressure drops > 15%, ambient humidity spikes > 10% from vapor escape, flow reductions > 20%, and gradual temperature shifts due to server component and rack air thermal inertia. The 7-day dataset contains 40,320 observations with 500 leak instances. III-A ML Models The ML engine uses dual models. LSTM forecasting employs 60-minute sliding windows through two stacked layers (128, 64 units) with 0.2 dropout, trained via MSE loss. Random Forest detection uses 100 trees at depth 15. Feature importance: humidity (51%), pressure (27%), flow (17%), temperature (5%), matching documented signatures [ 16 ] . III-B Probabilistic Forecasting Methodology The LSTM outputs point estimates \hat{y}_{t} of time-to-leak in hours. We convert these to probabilistic forecasts using calibrated prediction intervals derived from validation set errors. Specifically, we compute the empirical distribution of prediction errors e_{t}=|y_{t}-\hat{y}_{t}| on the validation set and use the 90th percentile error \epsilon_{90} to construct confidence bounds. A forecast \hat{y}_{t}\pm\epsilon_{90} translates to “90% probability leak occurs within \hat{y}_{t}+\epsilon_{90} hours.” Calibration validation compares predicted probability levels against actual coverage rates. For 90% probability forecasts predicting leaks within time window [\hat{y}_{t}-\epsilon_{90},\hat{y}_{t}+\epsilon_{90}] , we measure what fraction of actual leaks fall within this window. Our system achieves 87% empirical coverage for nominal 90% probability forecasts, demonstrating reasonable calibration. Forecasting model:

Read the complete text