Optimizing Sterile Neutrino Searches: Impact of Position Resolution in Short-Baseline Reactor Experiments

Young Ju Ko · 2025

Read Optimizing Sterile Neutrino Searches: Impact of Position Resolution in Short-Baseline Reactor Experiments by Young Ju Ko (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-20952.txt.

Introduction

Young Ju Ko asks how much the design of the device matters in the hunt for sterile neutrinos, ghost-like particles that may show up as subtle shifts in counts near a reactor. Ko models two designs at two Korean research reactor sites, HANARO and Kijang. One design is segmented. The other uses an opaque liquid that traps the light each event makes, so the event can be placed far more sharply.

Sharp placement wins. The opaque design reaches top sensitivity across a wide range of the unknowns, even under cautious guesses about fluxes and backgrounds. Knowing just where each event took place sharpens the pattern the team hunts for. The study gives future short-baseline tests a concrete reason to invest in imaging-grade placement.

Catalog record

CREATORYoung Ju Ko
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE25 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2512-20952

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Optimizing Sterile Neutrino Searches: Impact of Position Resolution in Short-Baseline Reactor Experiments Young Ju Ko Abstract The impact of position resolution on the sensitivity of short-baseline reactor neutrino experiments searching for light sterile neutrinos is investigated. Detailed simulations are conducted to evaluate two detector configurations: a segmented detector and an opaque liquid scintillator (OLS) detector, each positioned at two candidate research reactor sites, HANARO and Kijang. For both detector types, pseudo-data are generated under realistic assumptions regarding neutrino flux, detector response, and background levels. Oscillation analyses are performed to estimate detector sensitivity, incorporating both statistical and systematic uncertainties. The results indicate that the OLS detector, owing to its superior position resolution, achieves leading sensitivity across a wide range of oscillation parameters, even under conservative experimental conditions. These findings underscore the potential of OLS technology as a highly effective approach for future sterile neutrino searches. ]Received August 10, 2026 I Introduction In 2011, the reactor antineutrino anomaly (RAA) was reported Mention et al. 2011 , showing consistency with neutrino anomaly observed in gallium experiments Anselmann et al. 1995 ; Abdurashitov et al. 2006 . The RAA can be interpreted as the oscillation of light sterile neutrinos at the eV scale, which reignited interest in this possibility. This has led to numerous proposals for very short-baseline reactor neutrino experiments. Several of these proposals have been realized, with experiments either conducted or still ongoing Ko et al. 2017 ; Almazán et al. 2023 ; Andriamirado et al. 2021 ; Alekseev et al. 2018 ; Abreu et al. 2021 . However, except for Neutrino-4 Serebrov et al. 2019 , no definitive positive evidence has been observed. Recently, the BEST experiment provided additional support for the gallium anomaly Barinov et al. 2022 , interpreted as a sign of sterile neutrino oscillations. Furthermore, the IceCube collaboration reported a weak but potentially indicative signal related to sterile neutrinos Abbasi et al. 2024 . The current experimental landscape presents a mix of positive and negative results, leaving the field ambiguous. To resolve this, further experiments are underway or proposed. New detector technologies are being explored to enhance results from very short-baseline reactor neutrino experiments. Traditionally, experiments used homogeneous or segmented scintillator-based detectors, each with specific advantages and disadvantages. In particular, the segmented detectors have the advantage of being free from the use of a reference spectrum, which reduces systematic uncertainty when the baseline is sufficiently short. Therefore, segmented detectors may be preferred for research reactor experiments that can be installed at closer distances than experiments using commercial reactors. A novel design using opaque media Cabrera et al. 2021 offers excellent position resolution, introducing more pronounced trade-offs. In addition to the oscillation analysis advantages offered by segmented detectors, particle identification, which can distinguish between beta and gamma-ray signals, can lead to a dramatic reduction in background. This is a great advantage for experiments at research reactors with relatively high background due to shallow overburden. However, it may have limited energy resolution due to a short light attenuation length. Of course, there is room for improvement in energy resolution depending on the opacity of the media or the gap between fibers, but this study considers the energy resolution to be somewhat worse than other types of detectors. Therefore, the key question is whether enhanced position resolution outweighs the reduced energy resolution. This study provides a preliminary feasibility assessment, estimating detector sensitivity to sterile neutrino searches as a function of various experimental parameters. II Estimation of Sensitivities II.1 Assumptions for Experimental Setup The NEOS experiment, conducted at the Hanbit Nuclear Power Plant in South Korea, deployed a neutrino detector at Unit 5, securing a baseline of approximately 24 meters. With a sufficiently high thermal power of 3 gigawatts and the presence of substantial overburden, a homogeneous type detector was adopted. However, no significant signals indicative of sterile neutrino oscillations were observed Ko et al. 2017 . The reliance on reactor neutrino flux models, an inherent limitation of single-detector setups, largely negates the statistical advantage gained from increased data collection. Consequently, experiments under similar conditions offer limited benefits even if conducted over longer durations or with larger detector volumes. In contrast, experiments like STEREO and PROSPECT operate at research reactors, which have relatively lower thermal power and less overburden, resulting in a lower signal-to-background ratio. However, the advantage of closer proximity to the reactor provides significant benefits. To maximize these benefits and enhance background reduction, a segmented type detector was employed. This configuration can effectively function as a set of multiple identical and independent detectors placed at different distances from the reactor core, similar to the far-to-near ratio technique employed in multi-detector experiments Almazán et al. 2023 ; Andriamirado et al. 2021 . In the environment of research reactors, the primary advantage of opaque liquid scintillator (OLS) can be further maximized Cabrera et al. 2021 . OLS’s exceptional position resolution, similar to that of segmented ones, has a greater impact on oscillation analyses as the baseline is shortened. When the baseline reaches the meter scale, improvements in position resolution for a meter-scale detector can significantly enhance sensitivity. Additionally, this approach could incorporate the benefits of a multi-detector setup. The ability to mitigate flux model dependence in multidetector configurations—typically achieved by comparing event rates at different baselines—can instead be realized within a single detector by analyzing events at different positions inside it. Furthermore, superior position resolution plays a crucial role in background suppression. OLS technology offers a resolution high enough to distinguish interactions caused by beta particles and gamma rays Cabrera et al. 2021 . If the prompt signal by the positron from inverse beta decay (IBD) can be effectively separated from gamma-induced background events, most expected background sources could be eliminated. In very short-baseline research reactor experiments, the relatively low thermal power results in a smaller number of IBD events. Consequently, the high background caused by the low overburden becomes an even more critical issue, potentially limiting the sensitivity of the experiment. The use of OLS can significantly mitigate this issue. Based on these considerations, this study estimates the sensitivities for two detector configurations at two potential experimental sites. The first candidate site is the HANARO research reactor, a 30-MW thermal power facility located at the Korea Atomic Energy Research Institute in Daejeon. The second is a 15MW research reactor currently under construction in Kijang, Busan. The assumed baselines are 12 meters for HANARO and 7 meters for the Kijang reactor, determined based on expert consultation on reactor size and surrounding infrastructure. The background rate is assumed to be identical for both sites. Two detector configurations are considered: a segmented detector, similar to STEREO, and a homogeneous detector that utilizes OLS. It is assumed that both configurations have a rectangular volume of 1\times 2\times 1\,\mathrm{m}^{3} , positioned so that the variation in the distance from the reactor core is 2 meters. In the segmented detector type, five detector modules of 40 cm each are assumed, with position resolution effects not explicitly considered for each module. In contrast, for the OLS detector, a position resolution of 5 cm is assumed in each of the x, y, and z directions, based on reports suggesting centimeter-level resolution. Furthermore, the reactor core is considered a volume

Read the complete text