Calibration of an Irradiated Prototype for the EIC Zero-Degree Calorimeter
Miguel Arratia · 2025
Read Calibration of an Irradiated Prototype for the EIC Zero-Degree Calorimeter by Miguel Arratia (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-20852.txt.
Introduction
Weibin Zhang, Xilin Liang, Sean Preins, and Miguel Arratia stress-tested a detector part built for the future Electron-Ion Collider. Their prototype zero-degree calorimeter, with 563 channels, is about a tenth of the final device. It was blasted with proton beams to mimic one year of full-power running at the collider.
Radiation badly damaged the light sensors, unevenly across the device, just as expected in real operation. Even so, the team calibrated every channel individually using cosmic rays. The most damaged channels still produced a signal clearly above noise. The test reassures designers of this and other detectors using the same sensor-on-tile technology.
Catalog record
| CREATOR | Miguel Arratia |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 20 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2512-20852
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Calibration of an Irradiated Prototype for the EIC Zero-Degree Calorimeter Miguel Arratia Abstract We study the response of a prototype Zero-Degree Calorimeter (ZDC) detector to irradiation equivalent to 10 11 1-MeV protons/cm 2 , which matches the expected exposure after one year of operation at full nominal luminosity at the future Electron-Ion Collider (EIC). The prototype consists of 563 channels and represents about 10 percent of the final ZDC design in terms of both channel count and detector volume. It was irradiated at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL) with a dose equivalent to 10 11 protons/cm 2 . We demonstrate that, despite significant radiation damage to the SiPMs and non-uniform degradation across the detector volume, the detector can be successfully calibrated on a channel-by-channel basis using cosmic-ray data. The damage profile, similar to what is expected in the experiment, varies by an order of magnitude or more across the detector. Even for the most heavily damaged channels, the signal-to-noise ratio for a MIP signal remains above 5. This study provides a realistic test of the system’s performance under irradiation. It complements previous SiPM-specific irradiation studies and will inform the future operation of the ZDC and other detectors that use SiPM-on-tile technology. 1 Introduction The future Electron–Ion Collider (EIC) [ 2 , 1 ] to be constructed at Brookhaven National Laboratory (BNL) will be the first collider capable of delivering high-luminosity collisions of polarized electrons with polarized protons and light ions, as well as unpolarized heavy ions. The EIC will enable a broad program to study the spin and spatial structure of the nucleon and the emergent properties of nuclear matter in terms of quarks and gluons. To fully realize this program, the ePIC detector [ 9 ] has been designed as a comprehensive multi-purpose apparatus with specialized subsystems in the forward and backward regions. Silicon photomultiplier (SiPM)-on-tile technology [ 17 , 13 ] has been widely adopted across ePIC due to its compactness, scalability, and excellent photon detection efficiency. It is employed in both central and forward calorimetry, where the expected annual radiation levels vary by orders of magnitude, from about 10^{9} to 10^{12} 1-MeV n_{\text{eq}}/\text{cm}^{2} depending on detector position [ 1 ] . Among these systems, the Zero-Degree Calorimeter (ZDC) [ 14 ] is particularly exposed, as it detects neutral particles emitted at very small angles with respect to the beamline. The ZDC provides essential capabilities for tagging spectator neutrons in electron–ion collisions and identifying diffractive processes, and thus must maintain stable operation under sustained high radiation doses. This work continues a sequence of SiPM-on-tile calorimeter developments carried out by our group. The first-generation device, consisting of 10 layers and 40 channels, demonstrated the feasibility of the concept in a controlled beam test at Jefferson Lab [ 3 ] . A second-generation instrument, with 20 layers and 192 channels, was deployed in the STAR experiment at RHIC, where it provided the first operational validation of the technology under real collision and radiation conditions [ 18 ] . The present third-generation prototype extends the program with 23 layers and 563 channels, representing approximately 10% of the final ZDC design. The prototype was exposed to controlled irradiation at the NASA Space Radiation Laboratory (NSRL) at BNL, reaching a fluence of 10^{11} 1-MeV protons/cm 2 , equivalent to one year of EIC operation at nominal luminosity. This provided a realistic, system-level irradiation test of the detector. This paper studies pedestal and minimum ionizing particle (MIP) calibrations as diagnostics of SiPM degradation and detector stability under irradiation. Pedestal shifts and broadenings directly reflect radiation-induced dark current and noise evolution, while the MIP response provides a robust anchor for gain calibration and energy reconstruction. Together, these observables provide a comprehensive picture of SiPM performance under dose. By studying their evolution before and after irradiation, we demonstrate that despite substantial and non-uniform SiPM damage, channel-by-channel calibration with cosmic-ray data remains feasible and ensures adequate signal-to-noise performance. These results provide an essential benchmark for the long-term operation of the ePIC ZDC and offer broader insight for other ePIC subsystems based on similar technology. This paper is organized as follows. Section 2 describes the design and construction of the prototype and the irradiation setup. Section 3 outlines the calibration methodology. Section 4 presents the results of pedestal and MIP studies before and after irradiation. Section 5 discusses the implications of these findings for ZDC operation at the EIC, and provides a summary and outlook. 2 Prototype The prototype is a sampling calorimeter with 23 active layers interleaved with 22 absorber layers, as shown in Fig. 1 . Each layer consists of a 2 cm-thick steel absorber, a scintillator-tile layer, and a custom PCB with SiPMs mounted directly on it. The absorber layers are built from a 3\times 3 array of steel blocks, while each active layer contains 25 square scintillator tiles arranged in a 5\times 5 grid. Odd and even layers are diagonally shifted relative to each other to create smaller effective cells and improve spatial resolution, using the HEXPLIT reconstruction algorithm [ 15 ] . Figure 1 : Schematic plot (left) and picture (right) of the ZDC prototype. The steel blocks were reused from the STAR FCS upgrade [ 16 ] . Each block is a square prism measuring 9.5\times 9.5\times 2~\mathrm{cm^{3}} , with two pairs of blind holes on opposite faces (two per face) to accommodate dowel pins. The 2 cm thickness corresponds to 1.14 radiation lengths ( X_{0} ) and approximately 0.5 hadronic interaction lengths ( \lambda_{I} ). Each active layer consists of 25 EJ-212 scintillating tiles [ 8 ] wrapped in reflective ESR foil. A central dimple on the back of each tile houses a Hamamatsu S14160-1315PS 1.3-mm SiPM, air-coupled to the tile. The tiles are adhered onto a custom PCB that routes signals to adapter connectors for readout. Assembly began with three bottom steel plates with pre-drilled holes. The absorber blocks were then stacked layer by layer on top of the plates, up to three blocks high, and connected using dowel pins. An aluminum top plate, machined with the same hole pattern as the combined bottom plates, was placed on top of the absorber stack and secured with pins. The stacked absorber blocks created slots into which the PCB–scintillator assemblies were inserted from the side, with careful longitudinal alignment to maintain co-linearity with the absorber grid. The completed prototype measured approximately 30\times 30\times 60~\mathrm{cm^{3}} . A frame made of 80-20 bars, wrapped with blackout fabric, covered the prototype to make it light-tight. Each PCB is equipped with two adapter connectors, each supporting up to 13 channels. Custom 1 m ribbon cables link the adapters to CAEN FERS-5200 units (model DT5202) [ 5 ] , with compatible ports. Each CAEN unit provides five adapter ports; nine units are used to cover 22.5 layers, with the final layer reading out only half of its channels. In total, the system reads out 507 channels. The CAEN FERS system, based on the CITIROC-1A ASIC [ 4 ] , is adopted for prototyping and beam-test operation, while the final readout electronics for the EIC calorimeters, based on the EIC-custom CALOROC ASIC [ 7 ] , are still under development and not