Algorithms for Achieving Subpixel Resolution in Muon Tomography

Matthew Mark Romano, 1,2 JungHyun Bae, 2,∗ Paul Cantonwine 2 · 2025

Read Algorithms for Achieving Subpixel Resolution in Muon Tomography by Matthew Mark Romano, 1,2 JungHyun Bae, 2,∗ Paul Cantonwine 2 (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-20644.txt.

Introduction

Matthew Mark Romano, JungHyun Bae, and Paul Cantonwine work on muon tomography, a way of imaging with muons. Their task is subpixel resolution: pinning down where a particle crossed a detector more finely than the detector's own blocks allow. They find that machine learning methods reconstruct particle positions in scintillation-based detectors more accurately than standard approaches. Finer positions mean finer images of what muons pass through.

Catalog record

CREATORMatthew Mark Romano, 1,2 JungHyun Bae, 2,∗ Paul Cantonwine 2
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE15 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2512-20644

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Algorithms for Achieving Subpixel Resolution in Muon Tomography Matthew Mark Romano, 1,2 JungHyun Bae, 2,∗ Paul Cantonwine 2 Abstract 1 Introduction Muon tomography has emerged as a promising nondestructive imaging technique for monitoring the internal structure of dense and shielded objects by exploiting the natural flux of cosmic ray muons. Unlike conventional radiographic methods, which rely on transmitted photons or neutrons, muon imaging utilizes multiple Coulomb scattering (MCS) to infer material composition and geometry. This use of MCS means that muon tomography offers a unique advantage in nuclear energy and nuclear security applications, particularly for inspecting spent nuclear fuel canisters, verifying the integrity of dry storage casks [ 11 , 2 ] , and detecting the illicit trafficking of nuclear materials [ 4 , 3 ] . A critical limitation to the practical application of muon tomography systems is the spatial resolution of the tracking detectors—typically, scintillators or gaseous detectors with discrete readout granularity [ 8 ] . The finite pitch or segmentation of these physical detector elements inherently constrains the positional accuracy with which muon trajectories can be reconstructed. To transcend this hardware-imposed limit, subpixel resolution techniques become necessary. Achieving subpixel resolution—reconstructing muon positions with accuracy finer than the detector’s physical segmentation—is thus necessary for advancing the fidelity of muon imaging. However, subpixel positioning in muon detectors poses technical challenges. Muons are minimum ionizing particles that deposit limited energy in each interaction, and scintillation light yields can be sparse and variable. Additionally, light propagation within the scintillators introduces spatial diffusion, complicating the estimation of true interaction position. The pursuit of subpixel position reconstruction is especially valuable because it will enable significant performance gains using existing detector technologies and will thereby prevent the need for costly and complex hardware modifications. Such algorithmic enhancements are critical for overcoming the fundamental challenge of low cosmic muon flux at sea level, which limits imaging speed. By maximizing the accuracy of each measurement, these methods can make muon tomography a more practical and timely inspection tool. In this work, we investigated three computational approaches to achieve subpixel resolution in a simulated muon tomography system using a scintillator: (1) Centroid reconstruction method: a computationally lightweight technique that estimates the muon hit position based on the energy distribution across neighboring scintillator cells. (2) Maximum likelihood estimation (MLE): a statistically grounded method that seeks the most probable interaction position given the observed energy profile and detector response. (3) ML approach: a feedforward neural network trained on simulated data to infer muon positions based on engineered features derived from energy deposition patterns. Using a Geant4-based model of a four-plane scintillator system and 4 GeV muons, we evaluated each method’s ability to resolve muon interaction positions within a single detector plane. Our results indicate that all methods achieve subpixel localization; the ML method yields the highest accuracy, reducing mean positional error to just over 10% of the detector cell size. These findings support the potential of algorithmic advancements to substantially improve muon tomography performance without the need to modify existing detector hardware. Such innovations directly align with national priorities in cost-effective nuclear safeguards, nonproliferation, and radioactive waste monitoring, offering scalable improvements for next-generation imaging systems. 2 Multiple Coulomb Scattering Cosmic ray muon tomography relies on detecting the trajectories of naturally occurring muons to image dense materials. A typical muon tomography apparatus consists of two pairs of position-sensitive particle detectors installed before and after a scanning volume. Each pair of detectors records the 2D position of the muon. These position measurements are combined to reconstruct muon trajectories within the scanning volume. Because muons are charged particles, they undergo consecutive deflection when they interact with matter due to Coulomb interaction with nuclei and electrons. This phenomenon is known as MCS, and it is directly proportional to the atomic number (Z) of the material. The expected scattering angle distribution follows the Gaussian distribution with a zero mean, with the RMS projected angle \theta_{0} is given by Eq. (1) [ 9 ] : \theta_{0}=\frac{13.6\,\text{MeV}}{\beta cp}\sqrt{\frac{x}{X_{0}}}\left[1+0.038\ln\left(\frac{x}{X_{0}}\right)\right] (1) where \beta is the particle velocity in units of c , p is the momentum in MeV/c, x is the thickness of the material, and X_{0} is the radiation length of the material (which scales approximately as A/Z^{2} , where A is the atomic mass and Z is the atomic number). Although this analytical model aligns well with experimental results, low surface-level cosmic muon flux motivates more accurate reconstruction methods. Because practical detector configurations are often limited by pixel size, this coarse resolution limits imaging capabilities, motivating the development of subpixel reconstruction techniques. 3 Investigated Method Improvements 3.1 Detector Configuration and Simulation The muon tomography system is modeled using Geant4 version 11.3.2, employing the FTFP_BERT physics list with optical physics enabled for scintillation modeling. A typical muon tomography apparatus consists of four scintillator planes arranged in two pairs. For the purpose of this analysis, we focus on a single scintillator plane as the only constraint on trajectory resolution between two detectors is position resolution in one detector. The plane consists of an array of 8\times 8 individual scintillator cells, totaling 64 cells per plane. Each cell measures 6.25 × 6.25 cm, resulting in a total active detection area of 50 × 50 × 2 cm for each plane. Monoenergetic muons with an energy of 4 GeV (the average at sea level) were tested, and only small angles of incidence (< 0.25 rad) were considered to ensure that the muon traversed all four scintillators. Lastly, a conservative quantum efficiency of 10% was used. Muons traversing these cells deposit energy, which is the primary observable for reconstructing their path. This analysis is focused on the position reconstruction accuracy within a single scintillation detector plane based on the energy deposition patterns from simulated muon events. 3.2 Centroid Reconstruction Method The centroid method estimates the muon interaction position by calculating an energy-weighted average of the positions of the activated scintillator cells. The reconstructed position, \vec{r}_{\text{recon}} , is determined using Eq. 2 [ 6 ] : \vec{r}_{\text{recon}}=\frac{\sum_{i}E_{i}\vec{r}_{i}}{\sum_{i}E_{i}} (2) where E_{i} represents the energy deposited in the i -th scintillator cell, and \vec{r}_{i} represents the geometric center coordinates of that cell. This method assumes that cells closer to the true muon path will receive higher energy deposits and therefore weights their positions more heavily. Intuition for this assumption can be observed in Fig 1 . The 2D and 3D reconstructions clearly convey the energy centroid being centered near the true position of the muon. Figure 1: Visualization of the centroid method for a single simulated muon event. (Top) The heatmap displays the summed energy of optical photons (eV) in each scintillator cell. (Bottom) Cell volume is proportional to the energy distribution in each cell. 3.3 Maximum Likelihood Estimation The MLE method seeks to determine the muon interaction position (x,y) that most likely explains the observed pattern of energy depositions in the scintillator cells [ 1 , 12 ] . The detection of individual photons is a random, independent process, so the measured energy M_{k} in each cell k is assumed to be governed by Poisson statistics. The model, \{E_{k}(x,y)\} , then predicts the expected energy signal in cell k for a given muon position. For a proposed muon position (x,y) , the model

Read the complete text