Quantum Imaging of Birefringent Samples using Hong-Ou-Mandel Interference

Carolina Gonçalves, Tiago D. Ferreira, Catarina S. Monteiro, Nuno A. Silva · 2025

Read Quantum Imaging of Birefringent Samples using Hong-Ou-Mandel Interference by Carolina Gonçalves, Tiago D. Ferreira, Catarina S. Monteiro, Nuno A. Silva (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-19637.txt.

Introduction

Carolina Gonçalves and three co-authors turn a quantum effect into a microscope. Their tool is Hong-Ou-Mandel interference. Two photons that meet at a beam splitter tend to leave together. That leaves a dip in paired counts, and the dip shifts with tiny changes. The team aims the effect at clear samples that twist light's polarization. Past quantum microscopes of this kind failed on samples more than a few micrometers thick.

The fix is a photon-pair source with a long coherence length, over a millimeter. That stretches the dip, so normal thickness changes barely register. Shifts in the dip then track the twist in polarization. The team built a stats model and a best-fit method for the local twist angle. Scanned images match classic polarized-light images, while the setup runs at its sharpest setting.

Catalog record

CREATORCarolina Gonçalves, Tiago D. Ferreira, Catarina S. Monteiro, Nuno A. Silva
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE31 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2512-19637

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Quantum Imaging of Birefringent Samples using Hong-Ou-Mandel Interference Preprint: APS Carolina Gonçalves, Tiago D. Ferreira, Catarina S. Monteiro, Nuno A. Silva Abstract Two-photon interference in a Hong–Ou–Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent works have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length > 1 >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip centre are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation at a maximum-precision regime and insensitiveness to layer thickness. Overall, the approach enclosed provides a quantum-based quantitative imaging of birefringent structures, which can motivate further advantageous applications, including enhanced signal-to-noise ratio and lower damage imaging of photosensitive samples. I Introduction Polarization imaging and microscopy is an interesting technique that can be used to recover information that is invisible to the naked eye by measuring spatially resolved Stokes or Mueller matrices and inferring properties such as anisotropy, diattenuation, depolarization, chiral response, and stress distributions 18 . This information supports applications in diverse subjects from biomedical diagnosis 12 to remote sensing 24 and material characterization 25 , just to mention a few examples. Classically, implementations range from Mueller-matrix polarimetry and quantitative polarized-phase microscopy 10 to polarization-sensitive optical coherence tomography 8 . However, because these schemes rely on classical light and intensity-based detection, they are fundamentally limited by shot noise, reduced sensitivity under low-photon-flux conditions, and trade-offs between spatial resolution, acquisition time, and sample damage, particularly for the characterization of weakly scattering or photosensitive samples 16 . In recent years, these limitations have motivated a growing interest in the integration of quantum light sources into imaging systems 16 , promising to surpass classical limits with enhanced measurement accuracy, particularly under low-light conditions 25 , and nonlocal capabilities with significant advantages for remote sensing applications 3 ; 19 . From a broad perspective, quantum polarimetric sensing techniques can be categorized into fixed-delay correlation-based schemes and interferometric approaches exploiting Hong–Ou–Mandel (HOM) two-photon interference. In fixed-delay correlation schemes, experimental implementations typically employ polarization-entangled photon pairs in a polarizer–sample-analyzer configuration to characterize both the phase retardance and optical-axis orientation of anisotropic materials. The birefringence parameters are inferred from coincidence photon counts following well-defined polarization transformations applied across the sample or reference arm. This approach enables nanometer-scale precision in phase-retardance estimation 15 and angular accuracies below 1^{\circ} for the optical-axis orientation 11 ; 21 , while exhibiting enhanced robustness in low-photon-flux and noisy environments due to the intrinsic noise rejection afforded by coincidence detection 25 ; 29 . Fixed-delay correlation schemes encompass a range of related protocols, including quantum optical rotatory dispersion 23 , ghost polarimetry 20 , and distributed or nonlocal polarimetric measurements based on polarization-entangled photon pairs. In particular, the latter exploits polarization transformations exclusively in the reference arm, allowing nonlocal extraction of the polarization properties of the sample, thus minimizing optical complexity and perturbation in the measurement arm and enabling remote polarimetric sensing modalities 25 ; 3 ; 19 . On the contrary, HOM–based schemes explore two-photon interference to infer birefringence from changes in the depth and shape of the coincidence dip as a function of reference delay and relative polarization alignment of the photons in the two interferometer arms. With the polarization in the control arm typically kept fixed 22 ; 27 ; 28 , depth-resolved birefringence profiles can be obtained with techniques such as quantum optical coherence tomography (QOCT) and its polarization-sensitive variants (PS-QOCT), being immune to even-order dispersion 1 ; 5 ; 4 . Yet, to increase sensitivity, most HOM-based schemes utilize ultrabroadband photon-pair sources, yielding coherence lengths of only tens of micrometres 17 ; 4 . This is ideal for depth resolution, but makes the HOM dip highly sensitive to small changes in sample thickness, strongly limiting the application of the technique. To circumvent this limitation, this work explores the use of a narrowband single-photon source with a coherence length exceeding 1 mm to deliberately broaden the HOM dip. Operating at the broad, flat minimum of the dip, the measurement is intrinsically insensitive to small depth variations, making the coincidence rate governed by polarization-induced distinguishability rather than path-length fluctuations and enabling accurate characterization of the intrinsic birefringence of samples. Leveraging on this concept, we describe the implementation of a two-dimensional raster-scan quantum birefringence imaging technique, providing a theoretical framework of a statistical estimator for the birefringence angle that incorporates losses 15 that is shown to maximize the Fisher information and saturate the Cramér-Rao bound. II Methodology For sensing applications, Hong–Ou–Mandel (HOM) interference provides a sensitive probe of the environment by exploiting two-photon indistinguishability. Indeed, when two photons are combined on a balanced beam splitter, their coincidence rate of the output ports exhibits a characteristic dip whose depth is set by the overlap of the quantum states of the individual photons across all degrees of freedom (temporal, spectral, spatial, and polarization) 13 ; 6 ; 11 ; 21 ; 2 ; 27 ; 28 ; 26 ; 7 . In the particular case of polarization sensing, the introduction of a birefringent sample in one of the paths induces distinguishability between the polarization states of the photons, which reduces the quantum interference visibility and decreases the depth of the HOM dip up to its disappearance for orthogonal polarization states. The core of this work is set on the implementation of a microscopy setup that performs a raster scan of a sample and monitors the depth of the HOM interference dip, correlating it with the polarization state change and birefringence of the sample. Yet, contrary to other approaches previously reported in the literature 4 ; 22 , our solution explores a narrowband single-photon source to suppress sensitivity to variations in sample thickness, ensuring that the measured dip depth primarily reflects the birefringent properties of the imaged sample. II.1 Theoretical Model Figure 1: Schematic of the experimental setup. Photon pairs from a commercial narrowband SPDC source are separated into reference and sample arms. Polarizing beam splitters (not shown) and half-wave plates prepare and control the polarization in each arm. In the sample arm, two f=50\,\mathrm{mm} lenses focus the photons onto the sample, which is mounted on motorized x – y translation stages for raster scanning. The reference arm includes a motorized translation stage that controls the relative delay \Delta z , thereby setting the HOM-dip position. The photons are then recombined at a 50:50 beam splitter and detected with single-photon avalanche diodes. The coincidence events are recorded with a time-tagger. Bandpass filters centered