Time-domain anode–decoupling co-design for a floating MCP TOF-MS readout Preprint: The following article has been submitted to Review of Scientific Instruments. After it is published, it will be found at https://pubs.aip.org/aip/rsi . Copyright 2025 Authors. This article is distributed under a CC BY

Robin F. Bonny, Lorenzo Obersnel, Martin Rubin, André Galli, Peter Wurz, Rico G. Fausch · 2025

Read Time-domain anode–decoupling co-design for a floating MCP TOF-MS readout Preprint: The following article has been submitted to Review of Scientific Instruments. After it is published, it will be found at https://pubs.aip.org/aip/rsi . Copyright 2025 Authors. This article is distributed under a CC BY by Robin F. Bonny, Lorenzo Obersnel, Martin Rubin, André Galli, Peter Wurz, Rico G. Fausch (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-19495.txt.

Introduction

Robin Bonny, Lorenzo Obersnel, Martin Rubin, and André Galli redesign the readout of a microchannel plate detector for compact time-of-flight mass spectrometers. Space instruments need sharp timing from little mass and volume. Classic waveguide detectors are heavy, and floating electrical operation invites baseline wobble after each pulse.

Their co-design shapes the anode and its high-voltage decoupling network together, in the time domain. A flat circular patch anode with decoupling placed close by confines fields, keeps peak height, and settles fast. The decoupling capacitance sets the corner that governs undershoot decay. Bench tests show waveguide-level pulse quality at a fraction of the size.

Catalog record

CREATORRobin F. Bonny, Lorenzo Obersnel, Martin Rubin, André Galli, Peter Wurz, Rico G. Fausch
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE43 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2512-19495

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Time-domain anode–decoupling co-design for a floating MCP TOF-MS readout Preprint: The following article has been submitted to Review of Scientific Instruments. After it is published, it will be found at https://pubs.aip.org/aip/rsi . Copyright 2025 Authors. This article is distributed under a CC BY-NC-ND 4.0 International License. Robin F. Bonny, Lorenzo Obersnel, Martin Rubin, André Galli, Peter Wurz, Rico G. Fausch Abstract We present a microchannel plate detector for compact time-of-flight mass spectrometers (TOF-MS) that jointly optimizes the anode geometry and high-voltage AC-decoupling network for electrically floating operation. Undershoot-driven baseline artifacts and pulse broadening are addressed by a time-domain co-design of the anode geometry and decoupling network. The design is validated through a staged workflow that combines full-wave electromagnetic simulations, vector network analyzer measurements, circuit-level transient models, and end-to-end mass spectra. The resulting planar circular patch anode with anode-proximal decoupling confines fields, preserves peak amplitude, and suppresses post-pulse energy, leading to fast settling and minimal baseline wander. We show that the effective high-pass corner set by the decoupling capacitance directly governs undershoot decay and baseline recovery. Measurements in a representative TOF-MS test setup demonstrate waveguide-level pulse fidelity at a fraction of the mass and volume of heritage waveguide-based detectors, with residual ripples in the measured response originating from downstream cable and digitizer terminations rather than the detector itself. By limiting detector-induced temporal broadening and inter-peak baseline coupling, the design supports high mass resolution and dynamic range in miniaturized TOF-MS architectures. Variants of this planar flight-ready architecture are being implemented in several next-generation spaceborne TOF-MS instruments currently under development at the University of Bern. I Introduction I.1 Time-of-flight mass spectrometry Time-of-flight mass spectrometers (TOF-MS) have been instruments of choice for planetary exploration for multiple decades due to their fast acquisition rates, broad mass ranges, extensive dynamic range, and spectral continuity. 2 ; 27 ; 18 ; 13 A TOF-MS operates on the principle that ions, once accelerated by an electric field, separate according to their mass-to-charge ratio ( m/z ) during their flight. Mass spectra are acquired through pulsed operations: Ions with different m/z will arrive at a detector at distinct times 21 according to the relation t\propto\sqrt{m/z} and with respect to their extraction time. Therefore, precise measurements of the ion arrival times on the detector are critical to obtain high mass resolution. I.2 Detection limitations Since spaceborne mass spectrometers are allocated limited size, weight, and power budgets, there is an extrinsic need to miniaturize instruments. When downsizing time-of-flight mass spectrometers, the time of flight decreases and the mass resolution is reduced, as in R=m/\Delta m=t/(2\Delta t) . The detector has a considerable influence on the mass resolution of a TOF instrument. The time-resolving power ( \Delta t ) of a TOF-MS can be approximated as the quadrature sum of independent timing contributions; including ion-source pulse width, ion-optical aberrations, detector response, and electronics jitter. Among these, the detector contribution is set by its single-event pulse width, defined here as the full width at half-maximum (FWHM). To comply with the required ion-optical resolving powers of spaceborne instruments, for example, the Neutral Gas and Ion Mass Spectrometer (NIM) built for the Jupiter Icy Moons Explorer (JUICE) mission, 6 the detector pulse width ideally equals about 500\text{\,}\mathrm{ps} or less. When coadding multiple peaks into a histogram, the noise floor decreases and low-amplitude systematic artifacts after the main peak become apparent. Some features can be attributed to impedance mismatch, while others are characteristic of high-voltage decoupling capacitors in the signal transmission line that serve as AC-decoupling elements toward front-end electronics. In such purely AC-coupled readouts, the capacitors cannot sustain a net DC charge: Charge conservation requires that any positive transient through the capacitor be followed by an oppositely signed response. This behavior produces a characteristic undershoot that follows the main pulse. Additional features, such as small oscillations or extended tails, can arise from reflections at impedance transitions or from the limited bandwidth of the downstream stages. The combination of these artifacts compromises the detection of small peaks following large ones, effectively reducing the dynamic range of the TOF-MS when closely spaced peaks are present. For example, analyzing Xe isotopes 5 or Rb / Sr isotopes 10 becomes challenging, as such isotope patterns often result in small minor isotopologue peaks appearing in close succession after the large peaks of the main isotopologues. Moreover, this undershoot can complicate fully automated analysis of mass spectra, 12 since the baseline of a given peak would depend on the preceding ones and vice versa. These detector-specific limitations are central to the requirements of the compact TOF-MS architectures, including the Chemistry, Organics, and Dating Experiment (CODEX) instrument, currently under development and which serves as the primary testbed for the design and validation of the work presented in this paper. CODEX is part of the Dating an Irregular Mare Patch with a Lunar Explorer (DIMPLE) payload aboard a Commercial Lunar Payload Services (CLPS) lander. 3 ; 24 I.3 Detector architecture Spaceborne TOF-MS detectors often employ microchannel plates (MCPs), which convert an incident ion into an avalanche of electrons, collected on a downstream anode. 22 A single ion interaction produces a current impulse whose temporal shape is approximately Gaussian. 22 When many ions arrive within a narrow time window, the resulting ion-packet peak reflects both the intrinsic MCP response and the time dispersion introduced by the ion-optical system. Their relative contributions depend on the specific energy and mass range of the measurement. The MCP input side (MCP-front) is held at or slightly below the ion-optical reference potential of the mass analyzer. The MCP output side (MCP-back) is biased several hundred volts below this level to set the MCP gain, which may need to be adjusted over the lifetime of the MCP. To efficiently collect the electrons exiting the MCP, the anode surface is biased an additional 100\text{\,}\mathrm{V}200\text{\,}\mathrm{V} below MCP-back, providing sufficient post-acceleration while avoiding premature electron signals. Because the readout electronics are usually referenced to true ground, whereas the MCP and anode operate at several kilovolts of negative potential, the anode must be electrically floating relative to the readout chain. This floating configuration also decouples the detector from the ion-optical reference potential and therefore allows the drift voltage to be selected freely. The signal is AC coupled into the transmission line, and to obtain optimal signal fidelity, the AC-coupling capacitors must be located as close as possible to the anode surface. 26 The trade-off whether to implement an electrically floating anode was studied for the NIM instrument. 9 Floating the anode enables more degrees of freedom in the design and operation of the ion-optical system and MCP bias at the cost of requiring an anode-proximal AC-decoupling stage. The NIM trade-off study concluded that these advantages outweighed the added complexity. 9 Grounded-anode alternatives include segmented circular microstrip readouts 14 or fully impedance-matched transmission-line anodes directly connected to front-end electronics. 4 All detector configurations evaluated in this work assume a floating anode with a high-voltage AC-decoupling capacitor. A block-level overview of this architecture is shown in Fig. 1 and the detailed electrical layout is presented in Fig. 2 . Figure 1: Schematic MCP detector overview: floating anode with proximal AC-decoupling feeding a 50\text{\,}\mathrm{\SIUnitSymbolOhm} readout. Anode i_{\textsubscript{A}}\!(t) Z_{\textsubscript{A}} C_{1} C_{2} Z_{0} R_{3} R_{4} MCP-Back R_{2} R_{1} U_{1}

Read the complete text