Constraints on the polarization angle oscillations of the Crab Nebula with the Simons Array and its applications to the search for axion-like particles

Tylor Adkins, Shahed Shayan Arani, Kam Arnold, Carlo Baccigalupi, Darcy R. Barron, Bryce Bixler, Yuji Chinone, Matthew R. Chu, Kevin T. Crowley, Nicole Farias, Takuro Fujino, Masaya Hasegawa, Masashi Hazumi, Haruaki Hirose, Jennifer Ito, Oliver Jeong, Daisuke Kaneko, Brian Keating, Akito Kusaka, Adr · 2025

Read Constraints on the polarization angle oscillations of the Crab Nebula with the Simons Array and its applications to the search for axion-like particles by Tylor Adkins, Shahed Shayan Arani, Kam Arnold, Carlo Baccigalupi, Darcy R. Barron, Bryce Bixler, Yuji Chinone, Matthew R. Chu, Kevin T. Crowley, Nicole Farias, Takuro Fujino, Masaya Hasegawa, Masashi Hazumi, Haruaki Hirose, Jennifer Ito, Oliver Jeong, Daisuke Kaneko, Brian Keating, Akito Kusaka, Adr (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-18882.txt.

Introduction

Tylor Adkins and a large collaboration check whether the Crab Nebula's polarization angle wobbles, and use it to hunt axion-like particles. The Crab, or Tau A, calibrates polarization measurements across millimeter astronomy, so its steadiness matters. The team analyzed 90 GHz data from the Simons Array's 2023 season. Their paper, posted to arXiv in December 2025, follows up earlier POLARBEAR hints of oscillation.

No global oscillation signal appears. They cap the amplitude at 0.12 degrees with 95 percent confidence across the frequencies searched. Read as an axion search, that bound limits the axion-photon coupling below 3.84 times ten to the minus twelve, scaled by mass, for particle masses between 4.4 times ten to the minus twenty-two and 7.2 times ten to the minus twenty electron-volts. The earlier hints are neither confirmed nor fully excluded, leaving the case open.

Catalog record

CREATORTylor Adkins, Shahed Shayan Arani, Kam Arnold, Carlo Baccigalupi, Darcy R. Barron, Bryce Bixler, Yuji Chinone, Matthew R. Chu, Kevin T. Crowley, Nicole Farias, Takuro Fujino, Masaya Hasegawa, Masashi Hazumi, Haruaki Hirose, Jennifer Ito, Oliver Jeong, Daisuke Kaneko, Brian Keating, Akito Kusaka, Adr
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE53 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2512-18882

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Constraints on the polarization angle oscillations of the Crab Nebula with the Simons Array and its applications to the search for axion-like particles Preprint: APS/123-QED Tylor Adkins, Shahed Shayan Arani, Kam Arnold, Carlo Baccigalupi, Darcy R. Barron, Bryce Bixler, Yuji Chinone, Matthew R. Chu, Kevin T. Crowley, Nicole Farias, Takuro Fujino, Masaya Hasegawa, Masashi Hazumi, Haruaki Hirose, Jennifer Ito, Oliver Jeong, Daisuke Kaneko, Brian Keating, Akito Kusaka, Adrian T. Lee, Masaaki Murata, Lucio Piccirillo, Christian L. Reichardt, Kana Sakaguri, Praween Siritanasak, Satoru Takakura, Sayuri Takatori, Osamu Tajima, Kyohei Yamada, Yuyang Zhou, The Polarbear collaboration Abstract We present a search for polarization oscillation of the Crab Nebula, also known as Tau A, at millimeter wavelengths using observations with the Simons Array, the successor experiment to Polarbear . We follow up on previous work by Polarbear using 90 GHz band data of the 2023 observing season of the Simons Array to evaluate the variability of Tau A’s polarization angle. Tau A is widely used as a polarization angle calibration source in millimeter-wave astronomy, and thus it is necessary to validate the stability. Additionally, an interesting application of the time-resolved polarimetry of Tau A is to search for axion-like particles (ALPs). We do not detect a global signal across the frequencies considered in this analysis and place a median 95% upper bound of polarization oscillation amplitude A < 0.12 ∘ A<0.12^{\circ} over oscillation frequencies from 3.39 year -1 to 1.50 day -1 . This constrains the ALP-photon coupling at a median 95% upper bound of g a ​ γ ​ γ < 3.84 × 10 − 12 × ( m a / 10 − 21 ​ eV ) g_{a\gamma\gamma}<3.84\times 10^{-12}\times\left(m_{a}/10^{-21}\,\mathrm{eV}\right) in the mass range from 4.4 × 10 − 22 4.4\times 10^{-22} to 7.2 × 10 − 20 7.2\times 10^{-20} eV, assuming the ALP constitutes all of dark matter, its field is a stochastic Gaussian field, and it is the sole source of Tau A’s polarization angle oscillation. Additionally, we do not detect signal at the frequencies where 2.5 σ \sigma hints were previously reported by Polarbear , but we do not exclude these signals at the 95% confidence level. I Introduction Tau A, also known as the Crab Nebula, is a supernova remnant whose polarization emission is widely used as a polarization angle calibration source in millimeter-wave astronomy Aumont et al. 2010 ; Aumont et al. 2020 . The Polarbear collaboration recently demonstrated a method of investigating the time-varying polarization angle of Tau A using its 150 GHz band observations and reported a 2.5 \sigma hint of polarization oscillation at 1/61 day -1 and 1/52 day -1 [ POLARBEAR Collaboration 2024 , hereafter 3 ]. This potential variation is crucial for understanding the internal dynamics of Tau A and may be treated as a systematic error when using Tau A as a calibration source. Here we extend the results by applying the method to data from independent observations at 90 GHz with Polarbear -2a (PB-2a), the first receiver of the successor experiment of Polarbear , the Simons Array. In addition to probing the stability of Tau A as a millimeter-wave calibration source, 3 explored its applications to the search for axion-like particles (ALPs), assuming the observed time-varying polarization angle is induced by electromagnetic coupling to ALPs. The reported hint of signal is inconsistent with other studies searching for ALP-induced oscillations in the same mass range SPT-3G Collaboration 2022 ; Fedderke et al. 2019 ; PPTA Collaboration 2024 ; Sisk-Reynés et al. 2021 , highlighting the need for this paper to apply 3 ’s method as a consistency check. Originally proposed to solve the strong CP problem Weinberg 1978 ; Peccei and Quinn 1977a ; Peccei and Quinn 1977b ; Wilczek 1978 , the QCD axion and its generic pseudoscalar form, the ALP, are prime particle candidates of dark matter and are therefore of broad astrophysical interest. The ALP does not solve the strong CP problem and is motivated by string theories Weinberg 1978 ; Arvanitaki et al. 2010 ; Cicoli et al. 2012 . Without a fixed relationship between its mass and the Standard Model, the ALP mass is theoretically unconstrained over a broad range Ferreira 2021 ; Hui 2021 . For masses around 10 -22 eV, ALP dark matter resolves existing small-scale tensions in the standard cold dark matter model and fits the observed phenomenology of dark matter Hu et al. 2000 ; Hui et al. 2017 . In this paper, we exploit the ALP’s coupling to electromagnetism through the Chern-Simons term, introducing a birefringence of the ALP field Carroll et al. 1990 ; Harari and Sikivie 1992 and rotating the polarization angle of the photon propagating through the ALP field as \psi=\frac{g_{a\gamma\gamma}}{2}(\phi_{\mathrm{obs}}-\phi_{\mathrm{emit}}) (1) where g_{a\gamma\gamma} is the ALP-photon coupling, \phi_{\mathrm{obs}} is the ALP field where the photon is observed, and \phi_{\mathrm{emit}} is the ALP field where the photon was emitted. We consider the case in which the ALP behaves as wave-like dark matter, for which the time variation of its field is described by a single mode sinusoid with period h/(m_{a}c^{2}) where m_{a} is the ALP mass. For the mass range investigated in this study, 4.4\times 10^{-22} to 7.2\times 10^{-20} eV, the ALP’s coherence length is much shorter than the distance to Tau A Kaplan et al. 2008 and the ALP Compton wavelength is much smaller than the size of Tau A Hester 2008 . Thus, as in 3 , the ALP-induced polarization oscillation of Tau A can be modeled as \psi(t)=\psi_{0}+\frac{g_{a\gamma\gamma}\phi_{0}}{2}\sin\left(\frac{m_{a}c^{2}}{\hbar}t+\theta\right), (2) where \psi_{0} is the polarization angle of Tau A. In addition to studying the polarization angle variability of Tau A as a polarization angle calibrator at 90 GHz to extend Polarbear ’s study at 150 GHz, using the 90 GHz band data of PB-2a to study axion-like polarization angle oscillations enables a check against frequency-dependent systematics such as Faraday rotations to Polarbear ’s 150 GHz ALP search. This investigation into the PB24 ALP search is feasible because the ALP signal coherence time is greater than 100 years for the mass range of interest of this paper and thus remains coherent across Polarbear ’s observations from 2016–2017 and PB-2a from 2023. To follow up on the results of the previous publication, the analysis method is purposely kept as identical as possible. This paper is organized as follows: In Sec. II , we provide an overview of the instrument and its polarization modulator. In Sec III , we describe the Tau A observations used in this analysis. In Sec. IV , we describe the analysis method used in this paper, closely adapted from 3 , and in Sec. V , the framework used to check for internal consistency against spurious results. In Sec. VI , we present the results of the analysis in Tau A polarization angle oscillation and limits on the ALP-photon coupling constant. We close in Sec. VII with concluding remarks and expectations of a follow-up study by the Simons Array. II Instrument Overview II.1 Site, telescope and receiver The Simons Array is a millimeter-wave observatory on Cerro Toco in the Atacama Desert of Chile at an elevation of 5,200 m Suzuki et al. 2016 . It upgrades and expands the Polarbear instrument into an array consisting

Read the complete text