Measurement of Light Yield Response of Gd-compatible Water-based Liquid Scintillator with the Brookhaven 1-ton testbed Preprint: preprint for arXiv
S. Gwon, M. Askins, D.M. Asner, A. Baldoni, D.F. Cowen, R. Diaz Prerez, M.V. Diwan, S. Gokhale, S. Hans, P. Kumar, G. Lawley, S. Linden, G.D. Orebi Gann, J. Park, C. Reyes, R. Rosero, K. Siyeon, M. Smiley, J.J. Wang, M. Wilking, G. Yang, M. Yeh · 2025
Read Measurement of Light Yield Response of Gd-compatible Water-based Liquid Scintillator with the Brookhaven 1-ton testbed Preprint: preprint for arXiv by S. Gwon, M. Askins, D.M. Asner, A. Baldoni, D.F. Cowen, R. Diaz Prerez, M.V. Diwan, S. Gokhale, S. Hans, P. Kumar, G. Lawley, S. Linden, G.D. Orebi Gann, J. Park, C. Reyes, R. Rosero, K. Siyeon, M. Smiley, J.J. Wang, M. Wilking, G. Yang, M. Yeh (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-15968.txt.
Introduction
S. Gwon and co authors measure the light yield of gadolinium compatible water based liquid scintillator in a 2025 paper. The material mixes scintillation and Cherenkov light in one detector medium, which improves event reconstruction over conventional neutrino detectors. Optimizing future detectors needs hard numbers for how much light each mix gives.
Using cosmic ray muons in the Brookhaven 1-ton testbed, the team measures light yield at scintillator concentrations from 0.35 percent to 1 percent by mass. Yield rises from 69.16 plus or minus 6.92 photons per mega electron volt at 0.35 percent to 87.32 plus or minus 8.73 at 1 percent. Those values set a quantitative basis for designing later detectors.
Catalog record
| CREATOR | S. Gwon, M. Askins, D.M. Asner, A. Baldoni, D.F. Cowen, R. Diaz Prerez, M.V. Diwan, S. Gokhale, S. Hans, P. Kumar, G. Lawley, S. Linden, G.D. Orebi Gann, J. Park, C. Reyes, R. Rosero, K. Siyeon, M. Smiley, J.J. Wang, M. Wilking, G. Yang, M. Yeh |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 37 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2512-15968
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Measurement of Light Yield Response of Gd-compatible Water-based Liquid Scintillator with the Brookhaven 1-ton testbed Preprint: preprint for arXiv S. Gwon, M. Askins, D.M. Asner, A. Baldoni, D.F. Cowen, R. Diaz Prerez, M.V. Diwan, S. Gokhale, S. Hans, P. Kumar, G. Lawley, S. Linden, G.D. Orebi Gann, J. Park, C. Reyes, R. Rosero, K. Siyeon, M. Smiley, J.J. Wang, M. Wilking, G. Yang, M. Yeh Abstract The Water-based Liquid Scintillator (WbLS) enables hybrid detection by combining scintillation and Cherenkov signals, providing superior event reconstruction capabilities compared to conventional neutrino detectors. We measured the light yield of Gd-compatible WbLS at varying concentrations from 0.35% to 1% by mass, using cosmic-ray muons in a 1-ton scale detector at BNL. The light yield is measured as (69.16 ± \pm 6.92) ph / MeV at 0.35% concentration, which increased to (87.32 ± \pm 8.73) ph / MeV at 1%. These results establish a quantitative basis for optimizing future WbLS-based detectors in neutrino physics. I Introduction Large, kiloton-scale detectors are being planned and built around the world to investigate a wide range of physics, including the search for Beyond-Standard-Model phenomena, the detection of astrophysical neutrinos from sources like supernovae, and precision measurements of neutrino oscillations Abe et al. 2018 ; Adam et al. 2015 ; Abi et al. 2020 . They aim to precisely measure neutrino oscillation, proton decay, as well as serve as active shielding for dark matter direct detection experiments. The detector material that is widely used for such a large detector so far is a binary choice: either water, leveraging directional Cherenkov radiation, or organic liquid scintillator, producing a high yield of isotropic light. These technologies present a trade-off. While Water-Cherenkov detectors are easily scalable to huge volumes at low cost and provide excellent particle directionality, their high energy threshold and low light yield render them insensitive to low-energy events. Liquid scintillators overcome this limitation with their excellent light yield and correspondingly low energy threshold, but the scalability of liquid scintillators is limited by the high cost, chemical hazards, and environmental concerns of organic materials. This fundamental dilemma—a choice between cost-effective scalability and low-energy sensitivity—motivates the development of a hybrid technology. WbLS has been proposed as a next-generation detection medium to compensate for the shortcomings of both techniques while maximizing their advantages Caravaca et al. 2017 ; Akindele et al. 2023 ; Askins et al. 2020 ; Anderson et al. 2023 . WbLS is a medium in which a liquid scintillator is dispersed throughout pure water in the form of micelles. Based on this, it is expected to improve light yield and lower the energy threshold by scintillation, while retaining the existing infrastructure of conventional water-Cherenkov detectors. Moreover, the aqueous base allows efficient loading of neutron-capturing compounds such as gadolinium (Gd). The identification of neutron-capture events improves background discrimination and event reconstruction in neutrino measurements. In addition, the WbLS concentration can be tuned with precision to meet specific experiments’ goal. While previous study characterized the light yield and stability of 1% WbLS Xiang et al. 2024 , this study provides the first measurement of light yield as a function of Gd-compatible WbLS concentration from 0.35% to 1% by mass. These results establish a benchmark for optimizing future large-scale WbLS-based detectors. A similar measurement was performed and showed a comparable result with the BNL 1-ton testbed measurement Rosero et al. . II 1-ton WbLS Detector (a) (b) Figure 1 : (a) Schematic of the 1-ton detector. (b) Photograph of the 1-ton detector installed inside a light-tight dark box. The experiment was performed using the 1-ton WbLS demonstrator, built at Brookhaven National Laboratory (BNL) in 2022. It consists of a cylindrical transparent acrylic (Nakano UVT) tank with an outer radius of 575 mm and a height of 1275 mm. The tank is instrumented with a total of 58 photomultiplier tubes (PMTs), which are optically coupled to the acrylic surface with silicone gel pads referred to as “cookies”. Thirty 2-inch PMTs are placed on the bottom, and twenty-eight 3-inch PMTs (model 9821B) are arranged in seven rows on the side (two upper, three central, and two lower rows) as shown in Fig. 1 . Due to this unique geometry, Cherenkov light from vertically through-going muons (reffered to “crossing muon”) from top to bottom mainly reaches the bottom and side two rows of PMTs, while the top two rows are dominated by scintillation light. Based on this distribution, the PMTs are classified into two groups: those inside the Cherenkov cone of the crossing muon (“in-ring”) and those outside the cone (“out-ring”) as shown in Fig. 2 . This classification enables the disentanglement of the scintillation and Cherenkov components, which can subsequently be utilized for light yield analysis. Figure 2 : Conceptual diagram of the 1-ton WbLS detector showing the distinction between in-ring and out-ring PMT regions. The dashed lines represent the Cherenkov cone emitted by a through going muon, and the solid arrow indicates the muon’s path. Out-ring PMTs (blue) primarily detect isotropically emitted non-Cherenkov light (mostly scintillation light), whereas in-ring PMTs (red) are sensitive to both Cherenkov and non-Cherenkov light. To ensure stable optical properties of the WbLS for the duration of the measurement, a circulation system was used to maintain liquid purity, and the internal temperature was continuously monitored. Further details of the experimental setup can be found in the previous publication Xiang et al. 2024 . (a) (b) Figure 3 : (a) Two orthogonal layers of hodoscope array. (b) The bottom hodoscope array, positioned below the tank. To improve muon track reconstruction, additional segmented plastic scintillator arrays, serving as a hodoscope, were installed at both the top and bottom of the tank. Each hodoscope consists of two layers with eight 1-inch-wide scintillator bars. one layer is consists of eight plastic scintillator bars. Two layers oriented orthogonally, creating a 15 cm \times 15 cm overlapping region with 8 \times 8 segmentation, providing higher spatial resolution. Fig. 3(b) shows the bottom hodoscope installed beneath the PMTs. The hodoscopes aim to reconstruct the precise entry and exit location of muons, which reduces muon angle uncertainty significantly. However, the strict event selection required by the hodoscopes leads to lower statistics. Therefore, this hodoscope-tagged data is not used in the main analysis but serves as a independent set for validation. III Data Acquisition The data acquisition (DAQ) system processes, digitizes, and records the raw signals from the PMTs. The DAQ chain begins with an analog pulse from the PMT, which is then digitized by digitizer boards. A dedicated trigger system to select desired events records the digitized waveform. The PMTs are powered by multiple CAEN A7236N high-voltage (HV) modules, with connections via SHV cables. To minimize timing discrepancies between channels, all cables were matched in length, ensuring synchronization in signal arrival times. To ensure long-term operational stability, the output current from each module is continuously monitored and logged using the GECO2020 software. The analog signal from each PMTs is transferred to the digitizer system. The waveform is converted from analog to digital using three CAEN V1730 14-bit, 500 MS/s digitizers and one V1740 12-bit 62.5 MS/s digitizer. The acquisition time window is 1,920 ns. This window was specifically set for accurate time synchronization between the two different digitizer