Read Widefield Quantum Sensor for Vector Magnetic Field Imaging of Micromagnetic Structures by Orlando D. Cunha, Filipe Camarneiro, João P. Silva, Hariharan Nhalil, Ariel Zaig, Lior Klein, Jana B. Nieder (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-03748.txt.

Introduction

Many future devices, from magnetic memory to brain-inspired chips, depend on magnetic fields that vary across tiny structures. Orlando D. Cunha and colleagues show in a 2025 quantum sensing preprint how to photograph those fields with full direction information. Their tool uses nitrogen-vacancy centres, atomic defects in diamond that respond to magnetism, mounted on an ordinary commercial microscope.

The team adapted the microscope to run a pulsed measurement protocol that reads the shifts of all four defect orientations. From those shifts they rebuild the stray-field vector above microfabricated permalloy structures with several stable magnetic states. Images resolve details near half a micrometre across a wide field of view, and each acquisition takes only a few minutes. The authors present the setup as a practical, scalable way to inspect complex magnetic devices routinely, rather than a one-off laboratory demonstration.

Catalog record

CREATOROrlando D. Cunha, Filipe Camarneiro, João P. Silva, Hariharan Nhalil, Ariel Zaig, Lior Klein, Jana B. Nieder
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE31 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2512-03748

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Widefield Quantum Sensor for Vector Magnetic Field Imaging of Micromagnetic Structures Preprint: APS/123-QED Orlando D. Cunha, Filipe Camarneiro, João P. Silva, Hariharan Nhalil, Ariel Zaig, Lior Klein, Jana B. Nieder Abstract Many spintronic, magnetic-memory, and neuromorphic devices rely on spatially varying magnetic fields. Quantitatively imaging these fields with full vector information over extended areas remains a major challenge. Existing probes either offer nanoscale resolution at the cost of slow scanning, or widefield imaging with limited vector sensitivity or material constraints. Quantum sensing with nitrogen-vacancy (NV) centers in diamond promises to bridge this gap, but a practical camera-based vector magnetometry implementation on relevant microstructures has not been demonstrated. Here we adapt a commercial widefield microscope to implement a camera-compatible pulsed optically detected magnetic resonance protocol to reconstruct stray-field vectors from microscale devices. By resolving the Zeeman shifts of the four NV orientations, we reconstruct the stray-field vector generated by microfabricated permalloy structures that host multiple stable remanent states. Our implementation achieves a spatial resolution of ≈ 0.52 ​ μ ​ m \approx 0.52~\mu\mathrm{m} across an 83 ​ μ ​ m × 83 ​ μ ​ m 83~\mu\mathrm{m}\times 83~\mu\mathrm{m} field of view and a peak sensitivity of ( 828 ± 142 ) ​ nT ​ Hz − 1 (828\pm 142)~\mathrm{nT\,Hz^{-1}} , with acquisition times of only a few minutes. These results establish pulsed widefield NV magnetometry on standard microscopes as a practical and scalable tool for routine vector-resolved imaging of complex magnetic devices. I Introduction Micromagnetic textures serve as the foundation for a wide range of emerging spintronic technologies, including memory devices 2 , skyrmion-based logic 46 and neuromorphic architectures 51 that exploit multistable magnetic states. In all of these systems, the relevant information is encoded not only in the presence of magnetic fields but also in their spatial distribution. Quantitatively mapping these fields with micrometer-scale spatial resolution, over large areas and with full vector information is therefore essential for understanding and optimizing these devices. Several established techniques address parts of this problem, but each one comes with its own trade-offs. Electrical probes such as harmonic Hall measurements 17 ; 14 quantify effective spin–orbit torques and anisotropy fields, but they average over the device area and do not provide spatially resolved field maps. X-ray magnetic circular dichroism (XMCD) 3 ; 10 can image complex magnetization patterns, yet they require access to synchrotron radiation. Magneto-optical Kerr effect (MOKE) microscopy 23 ; 5 offers fast, widefield imaging of domains and dynamics, but it is limited to materials with a strong Kerr response and usually yields only partial vector information. As a result, none of these methods provides a quantitative map of the full magnetic-field vector. More recently, nitrogen-vacancy (NV) centers in diamond have emerged as one of the most promising quantum sensing platforms 8 . Their exceptional coherence properties at room temperature, optical addressability, and ability to reconstruct full magnetic vector fields make them ideal for investigating nano- and microscale magnetic phenomena 4 ; 45 . In their negatively charged state, NV centers have an electronic spin triplet ground state ( S=1 ). The Zeeman splitting of the m_{s}=\pm 1 spin states encodes the projection of the magnetic field along a crystal axis, which can be readout using optically detected magnetic resonance (ODMR). Since NV centers can align along four distinct \langle 111\rangle directions within the crystal, measuring the Zeeman shifts associated with each orientation allows for the reconstruction of the full three-dimensional magnetic field vector at the NV imaging plane. Figure 1: Illustration of nitrogen-vacancy (NV) vector magnetometry for imaging magnetic structures. A near-surface NV layer in diamond senses the stray field from microstructures, with each NV orientation measuring a different projection and enabling reconstruction of the magnetic-field vector. This principle has been explored with single NV centers in both scanning-probe and confocal implementations 37 ; 39 . These approaches provide nanoscale spatial resolution, but they require point-by-point scans and often demand more complex setups or protocols, especially for full vector reconstruction 16 . In contrast, when an ensemble of near-surface NV centers is combined with widefield imaging, every camera pixel effectively becomes an independent vector magnetometer, enabling parallel readout of the magnetic field over thousands of spatial points in a single acquisition 24 ; 38 . While this unlocks the potential for rapid wide-field imaging, the technique has thus far been limited to continuous-wave ODMR protocols and applied largely to simple, proof-of-principle samples 6 ; 27 ; 36 . In this work, we implement a camera-based pulsed ODMR protocol on a commercial widefield microscope, using a shallow implanted NV layer in bulk diamond to reconstruct the stray-field vectors generated by permalloy films (Figure 1 ). By fitting the ODMR spectra from the four NV orientations across the field of view, we extract the magnetic-field vector at the NV imaging plane. Beyond quantifying the spatial resolution and sensitivity of this platform, our results show that ensembles of NV centers provide a practical and accessible approach for the vector characterization of complex magnetic devices. II Experimental methods II.1 Nitrogen-vacancy center in diamond The NV center is a point defect in the diamond lattice consisting of a substitutional nitrogen neighboring a vacancy. Its negatively charged state forms a S=1 spin system with a ground state composed of the spin sublevel m_{\mathrm{s}}=0 and the degenerate m_{\mathrm{s}}=\pm 1 (see energy-level scheme in Figure 2 a). Without the presence of a magnetic field and at room temperature, the m_{\mathrm{s}}=\pm 1 are split from the m_{\mathrm{s}}=0 by D = 2.87 GHz. The spin-state-dependent intersystem crossing 12 ; 13 , combined with its non-radiative and non-conserving spin transition, allows the initialization into the m_{\mathrm{s}}=0 state and the readout of the spin state through their optical emission using ODMR techniques 43 . In the presence of an external magnetic field, the degeneracy of the m_{\mathrm{s}}=\pm 1 sublevels is lifted due to the Zeeman effect, as illustrated in the inset of Figure 2 a). This split is proportional to the projection of the magnetic field strength and can be expressed as 30 : B=\Delta v/2\gamma (1) where \Delta v is the difference in frequency between the m_{\mathrm{s}}=+1 and the m_{\mathrm{s}}=-1 , and \gamma\approx 28 \mathrm{GHz/T} is the NV gyromagnetic ratio. The vector reconstruction capability arises from the C_{3\mathrm{v}} symmetry property of the NV centers, which allows their alignment along one of the four possible [111] directions of the diamond. Since each NV center senses only the magnetic field projection along its quantization axis, by analyzing the Zeeman shifts from the four crystallographic orientations, it is possible to reconstruct the full 3D magnetic vector field 6 . II.2 Microstructured magnetic samples The multilayer stack of Ta (5 nm)/NiFe (100 nm)/Ta (5 nm) was deposited on a naturally oxidized Si wafer employing an Ion Beam Sputtering (IBS) unit. The patterning of two-crossing ellipse structures was carried out using a combination of photolithography, ion milling, and wet etching. Subsequently, a gold layer approximately 1.5 times thicker than the NiFe layer was deposited, patterned, and lifted off to form the electrical contact leads and pads. An exemplary optical image of the fabricated structure is shown in Figure 2 (b). Each ellipse measures 40 \mathrm{\mu m} in length and 5 \mathrm{\mu m} in width, having an aspect

Read the complete text