BART Streams: Real-time Reconstruction Using a Modular Framework for Pipeline Processing Publication type: Research Article
Philip Schaten, Moritz Blumenthal, Bernhard Rapp, Christina Unterberg-Buchwald, Martin Uecker, P. Schaten, M. Blumenthal, M. Uecker · 2025
Read BART Streams: Real-time Reconstruction Using a Modular Framework for Pipeline Processing Publication type: Research Article by Philip Schaten, Moritz Blumenthal, Bernhard Rapp, Christina Unterberg-Buchwald, Martin Uecker, P. Schaten, M. Blumenthal, M. Uecker (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-02748.txt.
Introduction
Philip Schaten and co-authors add live streaming to BART, a toolbox for magnetic resonance imaging reconstruction. Interactive real time MRI needs modular parts that pass data along a pipeline without pausing. Rebuilding images while the scan runs lets operators adjust on the fly.
A new protocol streams multidimensional arrays into BART's reconstruction algorithms. Demonstrations use radial FLASH imaging, mixing iterative reconstruction with dynamic coil compression and gradient delay correction. Live, modular reconstruction could shorten scans and improve imaging for moving organs, children, and guided interventions. Live views let a tech move the scan while the child still lies still, which cuts the need for a second pass in most cases.
Catalog record
| CREATOR | Philip Schaten, Moritz Blumenthal, Bernhard Rapp, Christina Unterberg-Buchwald, Martin Uecker, P. Schaten, M. Blumenthal, M. Uecker |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 45 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2512-02748
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
BART Streams: Real-time Reconstruction Using a Modular Framework for Pipeline Processing Publication type: Research Article Philip Schaten, Moritz Blumenthal, Bernhard Rapp, Christina Unterberg-Buchwald, Martin Uecker, P. Schaten, M. Blumenthal, M. Uecker Abstract 1 Purpose To create modular solutions for interactive real-time MRI using reconstruction algorithms implemented in BART. 2 Methods A new protocol for streaming of multidimensional arrays is presented and integrated into BART. The new functionality is demonstrated using examples for interactive real-time MRI based on radial FLASH, where iterative reconstruction is combined with advanced features such as dynamic coil compression and gradient-delay correction. We analyze the latency of the reconstruction and measure end-to-end latency of the full imaging process. 3 Results Reconstruction pipelines with iterative reconstruction and advanced functionality can be built in a modular way using scripting. Latency measurements demonstrate latency sufficient for interactive real-time MRI. 4 Conclusion With the new streaming capabilities, real-time reconstruction pipelines can be assembled using BART in a flexible way, enabling rapid prototyping of advanced applications such as interactive real-time MRI. \DeclareDelimAlias finalnamedelimmultinamedelim \authormark Schaten et al \corres Martin Uecker, Graz University of Technology, Institute of Biomedical Imaging, Stremayrgasse 16/3, 8010 Graz, AUSTRIA, \finfo This work was funded by DZHK (German Centre for Cardiovascular Research) grant 81X4300119 and in part by NIH under grant U24EB029240. \jnlcitation \cname , , ( \cyear 2025), \ctitle Real-Time MRI Reconstruction with BART Streams, \cjournal Magn. Reson. Med., \cvol ???. keywords MRI, Streaming, Real-Time MRI, Real-Time Reconstruction, Interventional MRI 5 Introduction Real-Time MRI (RT-MRI), the process of simultaneous measurement, reconstruction and low-latency display of MR images [ 11 ] provides a “live stream” from the inside of the human body. It is an important tool with emerging clinical applications, such as interventional [ 7 , 30 , 8 , 43 , 21 ] or fetal MRI [ 25 ] . RT-MRI usually requires high frame rates, e. g. to resolve cardiac motion [ 24 ] , speech production [ 22 , 26 ] , or joint motion [ 29 ] . It follows that relatively little data is available to reconstruct each frame. While this can be addressed by the use of advanced iterative reconstruction algorithms, RT-MRI presents two additional challenges: First, algorithms for (interactive) RT-MRI must be causal in the sense that reconstructed frames can only depend on previously acquired data, not on the whole dataset. Second, as latency must be kept low, reconstruction must be fast. One method which is well-suited for RT-MRI is the real-time regularized non-linear inversion (RT-NLINV) algorithm [ 42 , 41 ] . Based on classic regularized non-linear inversion (NLINV) [ 39 ] , RT-NLINV offers particularly high undersampling factors and is causal in the aforementioned sense. As iterative reconstruction is computationally expensive, running iterative RT-MRI reconstruction algorithms such as RT-NLINV in real-time typically requires optimized software and hardware acceleration e. g. through the use of Graphical Processing Units (GPU) [ 23 , 38 , 34 ] . The BART toolbox for computational MRI [ 2 ] is a comprehensive framework which provides a wide range of reconstruction, calibration [ 40 ] , machine-learning [ 3 , 1 ] , and signal processing tools. Its optimized code and its existing support for GPU computing make it an ideal choice for the development of real-time reconstruction methods. Another core feature of BART is its modular design as a toolbox: Algorithms are made available as individual command line tools, which typically take several parameters as well as in- and output data file names, enabling the construction of powerful reconstruction pipeline by combining the different tools in a script. High-quality RT-MRI requires not only highly optimized reconstruction, but also the ability to stream the data and reconstructed images during the measurement. Each reconstruction tool used in the reconstruction pipeline needs to perform its task as soon as a raw-data frame is available, as opposed to waiting for a complete dataset. In this work, we integrate new stream processing capabilities into BART. The new functionality facilitates building reconstruction pipelines suitable for RT-MRI with existing BART tools. Importantly, our approach to streaming builds on standard Unix system utilities, which allows us to preserve the full modularity of BART. This is demonstrated using examples for interactive real-time MRI based on radial FLASH, where iterative reconstruction is combined with advanced features such as dynamic coil compression and gradient-delay correction. We analyze the latency of the reconstruction itself and measure the end-to-end latency of the complete imaging process. 6 Methods We will first give an overview over the architecture of BART, then discuss multi-dimensional arrays, and then explain the new support for looping, and streaming, which is then used for real-time processing. 6.1 BART Structure BART is a modular reconstruction framework which enables building complex reconstruction algorithms through combination of various individual components. On the lowest level, a numeric library provides generic functions for operations on multidimensional arrays (md-arrays). Many of these operations can be accelerated using GPUs, or with the Message Passing Interface (MPI) [ 20 ] toolkit, enabling distributed computing on scientific high-performance clusters and multi-GPU usage [ 4 ] . The multi-dimensional operations are complemented by an operator library, which provides a simple way of constructing operators, e. g. the forward operator describing an MRI measurement, while automatically providing its adjoint in the case of a linear operator, or the derivative for non-linear operators. While the code is organized in the form of reusable libraries, their direct use is rarely needed. For most use cases it is sufficient to interact with BART using its command line interface, which consists of a set of high-level tools operating on md-arrays. All commands take several individual options and typically input and output file names. A single driver command, bart , acts as the unified entry point to BARTs command line interface. It can be called directly from a command line or from scripting languages such as BASH, Python or Matlab. The bart call is followed by a set of general options and the name of the tool which should be run. There are basic tools such as fft which calculates the Fourier transform of an md-array, as well as many commands for MRI-specific tasks such as whitening ( whiten ), coil compression ( cc ), calibration of sensitivities ( ecalib , ncalib ), parallel imaging and compressed sensing ( pics ), model-based reconstruction ( moba ), machine-learning reconstruction ( reconet , nlinvnet ), and much more. The tools act as building blocks and can be combined in a modular way to construct advanced reconstruction pipelines for all kinds of MRI applications. A complete reconstruction implemented with BART thus typically consists of a script that calls various BART commands that operate on md-arrays. For real-time reconstruction, it must be possible to split up, i.e. slice, the multi-dimensional input space and process each subset of the data as it becomes available. In other words, the reconstruction script has to be organized as a pipeline. To support this in BART while preserving its modular character, the tools were enhanced to support streaming of slices of md-arrays. 6.2 Slicing Suppose for n\in\mathbb{N} that we want to split up an n -dimensional array X\in\mathbb{C}^{N_{0}\times N_{1}\times...\times N_{n-1}} . In the following, the entries X_{(i_{0},...,i_{n-1})} of