Near-infrared polarimetric imaging with nonlinear flat-optics
2025
Read Near-infrared polarimetric imaging with nonlinear flat-optics (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2512-01525.txt.
Introduction
A compact platform images polarization in near-infrared light with flat optics. Polarization tells how light waves are aligned. It can reveal stress, form, and traits that plain images miss. Past tools for it were bulky and narrow in range.
The system uses second-harmonic generation in flat gratings. Each pixel's full polarization state is read from one shot. The parts are made from a dielectric that boosts the effect. A small, broad tool could serve in clinics, labs, and field sensors where size matters. Pixel-wise readout avoids scanning parts, so moving scenes can be imaged at video rates once the flat optics are scaled up.
Catalog record
| YEAR | 2025 |
|---|---|
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 52 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2512-01525
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Near-infrared polarimetric imaging with nonlinear flat-optics Abstract A compact and broadband polarimetric imaging platform is presented, based on second-harmonic generation (SHG) in nonlinear flat-optics. The system employs periodic all-dielectric AlGaAs gratings to induce polarization-dependent SH emission, enabling pixel by pixel direct retrieval of the full Stokes vector from an input intensity distribution in the near-infrared range. By engineering the geometry and orientation of the polarimetric units, sensitivity to linear and circular polarization components is achieved. A superpixel design comprising four polarimetric structures allows accurate reconstruction of the polarization state without moving parts or sequential measurements. This approach offers a scalable, passive, and cost-effective solution for polarimetric imaging, particularly suited for near-infrared applications. keywords Polarimetry, Second Harmonic Generation, Nonlinear optics, Nonlinear Circular Dichroism Evgenii Menshikov, Marco A. López Sánchez, Paolo Franceschini, Andrea Tognazzi, Domenico de Ceglia, Kristina Frizyuk, Costantino De Angelis ∗ , Evgenii Menshikov Università degli studi di Brescia, Via Branze 38, Brescia, Italy Marco A. López Sánchez Photonics Research Group, Ghent University-IMEC, Technologiepark-Zwijnaarde 123, Ghent, Belgium Dr. Kristina Frizyuk Karlsruhe Institute of Technology, Kaiserstrasse, 12, Karlsruhe, 76131, Germany Dr. A. Tognazzi Università degli studi di Palermo, Viale delle Scienze ed. 10, Palermo, 90128, Italy Istituto Nazionale di Ottica - Consiglio Nazionale delle Ricerche (INO-CNR), Via Branze 45, Brescia, Italy Dr. P. Franceschini, Prof. Domenico de Ceglia, Prof. C. De Angelis Università degli studi di Brescia, Via Branze 38, Brescia, Italy Istituto Nazionale di Ottica - Consiglio Nazionale delle Ricerche (INO-CNR), Via Branze 45, Brescia, Italy Email Address: [email protected] 1 Introduction An electromagnetic (EM) monochromatic plane wave has four degrees of freedom, namely the amplitude A , the phase \phi , the polarization orientation \psi , and ellipticity \chi [ 4 ] . In fact, the parameters \psi and \chi describe the so-called State of Polarization (SoP) and specify the properties of the electric field oscillations in the plane perpendicular to the propagation direction. This intrinsic property of radiation plays a crucial role in both the fundamental understanding of light features and in a variety of applications [ 36 ] . Indeed, the measurements and the analysis of the SoP ( i.e. , polarimetry [ 42 ] ) is of paramount importance in various fields, such as astronomy [ 11 ] , remote sensing [ 42 ] , quantum optics [ 27 ] , and biology [ 17 ] . In particular, imaging polarimetry (the technique aiming at mapping the SoP across a vast scene of interest), given its ability to analyze spatially varying light beams, allows one to retrieve information about the shape [ 16 , 31 , 2 ] and arrangement [ 28 , 40 ] of the reflecting structures, the orientation of light emitters [ 6 , 23 ] , or the optical activity of various materials [ 39 ] . Therefore, in the last decades, several methods have been developed to measure the SoP in an extended scene [ 42 ] . A widely spread representation of the SoP is given by the Stokes vector formalism [ 4 , 38 ] . Within this framework, the SoP of an arbitrary polarized wavefront is represented as a four-element vector, i.e. , the Stokes vector, \mathbf{S}=\left(S_{0},\,S_{1},\,S_{2},\,S_{3}\right) . Given a Cartesian reference frame xyz , with z being the propagation direction, the vector components are defined as S_{0}=I , S_{1}=I_{x}-I_{y} , S_{2}=I_{L+45}-I_{L-45} , and S_{3}=I_{\text{RCP}}-I_{\text{LCP}} . In the previous expressions, I is the total intensity of the light-field and the terms I_{x} , I_{y} , I_{L+45} , and I_{L-45} are the intensity of light in linear polarization component along the x (horizontal, H), y (vertical, V), +45^{\circ} , and -45^{\circ} direction, respectively. The terms I_{\text{RCP}} and I_{\text{LCP}} denote the intensity of the right-hand (RCP) and left-hand (LCP) circularly polarized light, respectively. From a conceptual point of view, the Stokes vector formalism allows to describe the SoP of the input light as the projection on three polarization basis sets: i) H/V ( S_{1} ), ii) \pm 45^{\circ} ( S_{2} ), and iii) RCP/LCP ( S_{3} ). Practically, this means that the value of the components S_{0} , S_{1} , S_{2} , and S_{3} can be directly determined by measuring the intensity (or power) in the different polarization bases. From an experimental point of view, this is a big advantage, since standard photodetectors operating at optical frequencies typically respond to changes in the intensity of the EM field (not to its phase). A typical polarimetry assessment setup always contains two parts: the polarization analyzer and the detection system (electric readout). The light detector probes the output response (such as an optical signal or photocurrent) resulting from the interaction between the analyzer and the incident radiation with unknown SoP. In the traditional approach, the radiation under analysis propagates sequentially through rotating polarizing elements (optical analyzer) and the transmitted intensity is measured by a photodetector [ 38 ] . The SoP is thus determined from several (a minimum of four) intensity measurements by properly arranging the polarizing elements in front of the detector. This takes relatively long acquisition times and it is not capable to monitor transient events. Another method consists in performing parallel measurements by splitting the beam into several optical paths and using multiple polarizers and detectors [ 42 , 10 ] , but result in inherently complex and bulky systems. These limitations were alleviated with the development of integrated polarimetric devices employing variable liquid crystal retarders [ 43 , 30 ] . These devices are designed to dynamically modulate the retardance values under an external voltage, allowing the full polarization state to be reconstructed from sequential measurements. More compact implementations include thin-film analyzers (micropolarizer gratings) [ 20 , 19 ] and devices based on two-dimensional (2D) materials, exploiting their anisotropic absorption [ 46 ] . While both types of devices exhibit strong sensitivity to linear polarization, their response to circular components is usually absent or quite limited, requiring more advanced designs [ 13 , 3 , 47 ] . In the past decade, metasurfaces (optical elements composed of judiciously arranged nanoscatterers) have opened new avenues in the manipulation of light’s amplitude, phase, and SoP [ 45 , 44 , 25 ] . Among a wide variety of applications, dielectric metasurfaces have been successfully employed also for imaging polarimetry [ 1 , 37 , 22 ] . In these devices, the extended wavefront impinges onto the polarimetric unit composed of an ordered array of unit elements with specific shapes and/or orientations. The individual polarimetric units (called super-pixels) comprise a set of optical metasurfaces, each one being designed to respond only to one of the three polarization basis ( e.g. , H/V, \pm 45^{\circ} , or RCP/LCP) and it splits the two orthogonal states of polarization to different points on the detection plane. The determination of the Stokes parameters is achieved by measuring the intensity at image sensor pixels on the detector plane, corresponding to one single super-pixel on the analyzer plane. Further advances along this path are represented by the integration of a metasurface analyzer directly with a photodetector, enabling an extremely compact and self-contained polarimetric platform [ 26 , 41 , 48 ] . In this case, the individual super-pixel comprises a few sensing units (three or four depending on