Read X-ray Microscopy Study of Freezing Sessile Droplets by Jae Kwan Im, Hyeonjun An, Seob-Gu Kim, Jae-Hong Lim, Joonwoo Jeong (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-20571.txt.
Introduction
Im, An, Kim, Lim, and Jeong watch water droplets freeze through X-ray eyes. Their 2025 paper studies sessile droplets, drops sitting on a cold surface. A freezing drop grows a sharp point at its top. Water expands as it turns to ice, forcing that tip. The tip angle was thought to be universal across conditions.
In situ X-ray imaging shows the angle shifts with surface temperature. Trapped bubbles during freezing cause the drift from the classic value. Three-dimensional tomography measured the ice-water density ratio directly. Bubbles lower the effective ratio below the pure value. Feeding that ratio into the theory reconciles the angles. A bubble-free drop frozen in vacuum showed the classic angle again. The team also measured three-phase boundary angles during freezing. Those readings validate the geometric theory of tip formation. High-resolution X-ray imaging proves a sharp tool for ice research.
Catalog record
| CREATOR | Jae Kwan Im, Hyeonjun An, Seob-Gu Kim, Jae-Hong Lim, Joonwoo Jeong |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 20 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2511-20571
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
X-ray Microscopy Study of Freezing Sessile Droplets Preprint: APS/123-QED Jae Kwan Im, Hyeonjun An, Seob-Gu Kim, Jae-Hong Lim, Joonwoo Jeong Abstract A sessile water droplet on a cold substrate freezes into a shape with a sharp apex because of water’s expansion upon freezing, yielding a universal tip angle across various conditions. Using in situ X-ray imaging, we report that this angle changes with substrate temperature, and the deviation originates from bubble formation during freezing. Three-dimensional tomography enables direct quantification of the effective ice-water density ratio, accounting for trapped bubbles. Incorporating this effective density ratio reconciles the temperature-dependent tip angles. We also confirm that a bubble-free frozen droplet in a vacuum chamber exhibits the universal tip angle. Furthermore, X-ray imaging allows us to measure the three-phase boundary angles in situ , thereby validating the geometric theory behind tip formation. These findings advance our understanding of the freezing dynamics associated with multiphase systems and highlight the capabilities of high-resolution X-ray imaging in ice research. The freezing of water is a ubiquitous phenomenon with significant implications across natural and engineered systems. Ice not only plays a central role in polar ecosystems, climate, and planetary processes Snodgrass et al. 2017 ; Noble et al. 2020 ; Holland and Hunke 2022 , but also poses significant challenges to safety, reliability, and efficiency in technological contexts spanning from aviation and thermal management to food preservation and biomedical cryopreservation Jaiswal and Vagga 2022 ; Rekuviene et al. 2024 ; Zhang et al. 2024 ; Mckenzie et al. 2024 ; Aarattuthodi et al. 2025 ; Tian et al. 2025 . The complex nature of freezing and melting stems from their multi-physics and multi-component characteristics. For example, coexisting, coupled gradients in density, temperature, and solute concentration can lead to fluid and material transport, as well as phase separation. These effects manifest as gas inclusions Carte 1961 ; Madrazo et al. 2008 ; Hruba and Kletetschka 2018 ; Chu et al. 2019 ; Meijer et al. 2024 ; Shao et al. 2025 , brine channels, and residual liquid films Singha et al. 2018 ; Kamm et al. 2023 ; Chu et al. 2024 ; Kharal and Louf 2024 ; Zhu et al. 2024 ; Gao et al. 2025 in natural ice having complicated internal structures. The sharp tip formed by a frozen water droplet on a cold plate Anderson et al. 1996 ; Ajaev and Davis 2003 ; Snoeijer and Brunet 2012 ; Enríquez et al. 2012 ; Marín et al. 2014 is one of the most fascinating freezing phenomena that even pure water can exhibit, including ice spikes and snowflakes Hill et al. 2004 ; Libbrecht 2005 . The surface-tension-defying formation of the tip singularity has been attributed to the expansion of liquid upon solidification Kolasinski 2007 . The geometry of the freezing front—a spherical-cap shape that ends perpendicularly to the solid-air interface—is responsible for the formation of the pointy tip and its universal angle regardless of the substrate temperature or the contact angle on a substrate Marín et al. 2014 . Here, we employ synchrotron X-ray imaging to resolve the fast dynamics of the freezing process and the 3D internal structure of the frozen droplets, enabled by X-ray tomography. By overcoming the limited spatial and temporal resolution in previous studies Snels et al. 2023 ; Wu et al. 2025 , we quantitatively characterize the geometry of the freezing front and the trapped bubbles, whose sizes and spatial distributions depend on the freezing rate. These observations reconcile the slight mismatch between experiments and theory reported in Marín et al. Marín et al. 2014 and propose a revised model that accounts for trapped bubbles and the resulting substrate-temperature-dependent tip angles. Figure 1: X-ray imaging of the freezing process of a sessile water droplet placed on the cold polycarbonate plate. After placing a droplet of 2\text{\,}\mathrm{\SIUnitSymbolMicro L} in volume on the substrate at room temperature, we decrease the substrate temperature to -5\text{\,}\mathrm{\SIUnitSymbolCelsius} . (a) The sketch of the experimental setup. Four distinct stages of the droplet freezing are shown. (b) Liquid cooling. A droplet remains in the supercooled liquid phase despite sub-zero substrate temperature. The black scale bar is 500\text{\,}\mathrm{\SIUnitSymbolMicro m} . (c) Recalescence. Dendritic ice nucleates; the inset with the white 100 \mathrm{\SIUnitSymbolMicro m} scale bar displays its magnified view. (d) and (e) Freezing. Curved water(top)-ice(bottom) interface, water-ice-air boundary, and the trapped air bubbles are visible. (f) Solid cooling. The completely frozen droplet forms the pointy tip at the top. Elapsed time after the recalescence is shown in the top-right corner. X-ray imaging visualizes the internal structure of a freezing water droplet with a pointy tip. The whole freezing process of a water droplet on a cold plate can be divided into four distinct stages based on its temperature transition characteristics: (1) liquid cooling (supercooling), (2) recalescence (nucleation), (3) freezing with an ice front advancing from the cold substrate, and (4) solid cooling Hindmarsh et al. 2003 ; Chaudhary and Li 2014 ; Wang et al. 2021 . In the liquid cooling stage shown in Fig. 1 (b), the water droplet remains in the supercooled liquid phase, and its temperature decreases below 0\text{\,}\mathrm{\SIUnitSymbolCelsius} . Figure 1 (c) captures the moment of recalescence, which typically lasts tens of milliseconds Chaudhary and Li 2014 ; Wang et al. 2021 . When a supercooled droplet forms ice nuclei and releases the latent heat, its temperature rises to 0\text{\,}\mathrm{\SIUnitSymbolCelsius} . Then, as shown in Figs. 1 (d) and 1 (e), the ice grows from the bottom. In our X-ray observation, the three-phase boundary between ice, water, and air, as well as the formation of the pointy tip, is clearly visible. Notably, while the pointy tip is known to adopt a universal angle of 139\pm 8 \mathrm{\SIUnitSymbolDegree} Marín et al. 2014 , regardless of the substrate’s temperature and surface chemistry, we observe tip angles below this universal value at higher substrate temperatures. As plotted in Fig. 2 (f), the deviation from the universal value becomes more pronounced as the substrate temperature increases, with the tip angle reaching approximately 120\text{\,}\mathrm{\SIUnitSymbolDegree} at -5\text{\,}\mathrm{\SIUnitSymbolCelsius} . Figure 2: Effect of trapped bubbles on the tip angle according to the substrate temperature. The representative 2D X-ray images of the frozen water droplets of 1\text{\,}\mathrm{\SIUnitSymbolMicro L} in volume on a cover glass at (a) -5\text{\,}\mathrm{\SIUnitSymbolCelsius} , (b) -10\text{\,}\mathrm{\SIUnitSymbolCelsius} , and (c) -20\text{\,}\mathrm{\SIUnitSymbolCelsius} , respectively, in the ambient condition. The representative images of the bubble-free frozen water droplet on a cover glass at (d) -5\text{\,}\mathrm{\SIUnitSymbolCelsius} and (e) -20\text{\,}\mathrm{\SIUnitSymbolCelsius} , respectively, in a vacuum chamber. All scale bars are 200\text{\,}\mathrm{\SIUnitSymbolMicro m} . (f) Measured tip angles depending on substrate temperature and presence of bubbles. The black-filled circles and red-empty triangles represent the tip angles of individual frozen droplets with bubbles and without bubbles, respectively. The center line of the box plot corresponds to the median of each dataset, and the top and bottom lines are the 75th and 25th percentiles, respectively. Blue solid line at 139 deg and the band around it indicate the average and standard deviation of the tip angles reported in Marín et al. Marín et al. 2014 : 139\pm 8 \mathrm{\SIUnitSymbolDegree} . To reconcile this deviation in the tip angle, we focus on the temperature-dependent trapping of air bubbles