Pile-up simulator for XRISM/Xtend onboard the X-ray Imaging and Spectroscopy Mission (XRISM)
Tomokage Yoneyama, Tsubasa Tamba, Hirokazu Odaka, Aya Bamba, Hiroshi Murakami, Koji Mori, Yukikatsu Terada, Masayoshi Nobukawa, Tsunefumi Mizuno · 2025
Read Pile-up simulator for XRISM/Xtend onboard the X-ray Imaging and Spectroscopy Mission (XRISM) by Tomokage Yoneyama, Tsubasa Tamba, Hirokazu Odaka, Aya Bamba, Hiroshi Murakami, Koji Mori, Yukikatsu Terada, Masayoshi Nobukawa, Tsunefumi Mizuno (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-19967.txt.
Introduction
Tomokage Yoneyama and eight co-authors build a simulator for a detector problem on the XRISM X-ray mission. Xtend, one of the mission's two telescopes, is a CCD camera with a wide field of view. When a bright source is observed, photons can pile up in one pixel and fake a lower flux, so observers must pick the right camera mode for each target.
Their pile-up simulator estimates the effect from a source's flux, spectrum, and shape. For a point source with a Crab-like spectrum, they derive the count rates at which pile-up reaches ten percent in each of Xtend's three window modes. They also present simulations for a diffuse source and for single-energy spectra, giving observers a practical planning tool.
Catalog record
| CREATOR | Tomokage Yoneyama, Tsubasa Tamba, Hirokazu Odaka, Aya Bamba, Hiroshi Murakami, Koji Mori, Yukikatsu Terada, Masayoshi Nobukawa, Tsunefumi Mizuno |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 18 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2511-19967
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Pile-up simulator for XRISM/Xtend onboard the X-ray Imaging and Spectroscopy Mission (XRISM) Tomokage Yoneyama, Tsubasa Tamba, Hirokazu Odaka, Aya Bamba, Hiroshi Murakami, Koji Mori, Yukikatsu Terada, Masayoshi Nobukawa, Tsunefumi Mizuno Abstract In X-ray astronomy, most observatories utilize multi-pixel photon-counting devices. When a photon-counting device observes a bright source, we face an unavoidable problem called pile-up. Pile-up leads to mistakes in the observational properties of the source, mainly an apparent decrease in the X-ray flux. X-Ray Imaging and Spectroscopy Mission ( XRISM ) has two X-ray telescopes, one of which is Xtend, a CCD camera with a wide field-of-view (FOV) of 38 arcmin square. Xtend has three operating modes: full window mode with a frame exposure of ∼ \sim 4 sec, 1/8 window mode with ∼ \sim 0.5 sec and reduced FOV, and 1/8 window mode with burst option, whose frame exposure is reduced to ∼ \sim 0.06 s. Observers need to select the operating mode according to their target fluxes. We develop the pile-up simulator for Xtend to provide a quantitative assessment of pile-up according to the fluxes, spectra, and shapes of X-ray sources. We derived the 10% pile-up limits for a point source of 7.8, 66.2, and 447.9 counts s -1 for full window, 1/8 window, and 1/8 window mode with burst option, respectively, by assuming the Crab spectrum. We present further simulations for a diffuse source and monochromatic spectra. keywords charge-coupled-devices, x-rays, astronomy, telescopes, simulations * Tomokage Yoneyama, \linkable [email protected] 1 Introduction Most recent X-ray astronomical satellites equip photon-counting devices as focal plane detectors of the X-ray telescopes to perform imaging spectroscopy and timing analysis. Once an X-ray photon enters a photon-counting device, an electron cloud is generated by the photoelectric effect. Because of the large energy of the X-ray photon, the electron cloud may spread over several pixels, from which an X-ray event is reconstructed. The signal patterns of X-ray photons on the frame image must be distinguished from those of non-X-ray signals, such as cosmic rays. The so-called Grade algorithm introduced for ASCA /SIS [ 6 ] has been employed to classify whether the extracted events are caused by incident X-ray photons or not. When the Grade algorithm is applied, a photon-counting device assumes that only one photon is detected in an adjacent 3 \times 3 (or 5 \times 5) pixels within a single readout frame. If the device observes an X-ray source bright enough to violate this assumption, more than two photons may enter the same pixel or several nearby pixels within a single readout. This is called pile-up, an unavoidable issue for photon-counting devices. Once a pile-up occurs, multiple photons are detected as a single photon event with their combined energy, or as a bad-grade event. This leads to mistakes in the observational properties of the source, mainly an apparent decrease in the X-ray flux and distortion of the spectral shape, which mainly appears as a hardening. X-ray telescopes utilizing CCDs as multi-pixel photon-counting devices for imaging and spectroscopy, such as ASCA [ 17 ] , Chandra [ 20 ] , XMM-Newton [ 10 ] , and Suzaku [ 11 ] , have operating modes to mitigate the pile-up for bright sources. Many studies have been presented to attribute the pile-up. Ballet (1999) [ 4 ] and Ballet (2003) [ 5 ] reported theoretical studies for pile-up focusing on detectors with small pixels compared to the point spread function (PSF) of X-ray mirrors. They took only single-pixel events into account. Davis (2001) [ 8 ] presented an analysis model for X-ray spectra affected by the pile-up, introducing grade-migration probability. The model does not consider the energy dependence of the pile-up, which is in reality significant. Recently, Sevilla (2017) [ 15 ] constructed an analytic model of the pile-up considering the probability that a detector observes n counts if N particles are incident in a single exposure frame when incident photons have a Poisson distribution. They applied the model to the XMM-Newton observation of an X-ray pulsar. Dauser et al. (2019) [ 7 ] presented a mission-independent simulation toolkit, the simulation of X-ray telescopes (SIXTE), which was applied to study the pile-up of Athena-WFI. X-Ray Imaging and Spectroscopy Mission ( XRISM ) [ tashiro24 ] launched on 2024-09-07 equips two X-ray telescopes, Resolve [ 9 ] and Xtend [ 13 ] . Xtend is a combination of a Wolter I-type X-ray telescope, X-ray Mirror Assembly (XMA), and a CCD camera array, Soft X-ray Imager (SXI), whose specification is summarized in table 1 . Xtend performs a wide-field X-ray imaging spectroscopy with a field of view (FOV) of 38.5 arcmin square and a wide bandpass of 0.4 – 13.0 keV with energy resolution of \sim 180 eV at 6 keV. Three operating modes are implemented for Xtend: full window mode with a frame exposure of 4 sec, 1/8 window mode with 0.5 sec and reduced FOV, and 1/8 window mode with a 0.1 s burst option. Specification of each mode is summarized in table 2 . Observers should select an appropriate mode that meets their scientific purposes and the source brightness to minimize the pile-up. We develop the pile-up simulator for Xtend to provide a quantitative assessment of pile-up according to the fluxes, shapes, and spectra of X-ray sources. In this paper, we report the development of the pile-up simulator, its application, and the anticipated effects of pile-up for Xtend. Table 1: Specification of Xtend/SXI CCDs CCD Type Frame transfer, p-channel, Backside illuminated Number of CCDs 4 Number of segments per CCD 2 Imaging area 31 \times 31 mm 2 , 640 \times 640 logical pixels Pixel size 48 \times 48 \mu m (logical pixel) Plate scale 1 ′′ .77 pix -1 (logical pixel) Depletion depth 200 \mu m Optical Blocking Layer (OBL) Al (200 nm) on the CCD surface Contamination Blocking Filter (CBF) Al (80 nm)/Polyimide (200 nm)/Al (40 nm) Nominal operating temperature - 110 ∘ C Table 2: Available operation modes of Xtend Image Size ∗ Time Res. Frame Exposure LTF † (pixels \times pixels) (sec) (sec) Full Window 640 \times 640 4 3.9631 0.99 1/8 Window 640 \times 80 0.5 0.4631 0.93 1/8 Window with 0.1 s Burst 640 \times 80 0.5 ‡ 0.0620 0.12 Live time fraction Photon arrival times are determined with 0.062 sec accuracy. 2 PILE-UP SIMULATOR The Xtend pile-up simulator is based on Tamba et al. (2022) [ 16 ] , which is the simulation framework for Suzaku /XIS. It simulates the physical processes of how incident X-ray photons interact in a detector, appear as signals on a frame image, and are extracted as events. All functions constructing the simulator are implemented in a framework for X-ray detector and data analysis simulation, ComptonSoft (Odaka et al. 2010 [ 14 ] ). ComptonSoft performs Monte Carlo simulations of X-ray photons interacting with detectors based on Geant4 (Agostinelli et al. 2003 [ 1 ] ; Allison et al. 2016 [ 2 ] ), a library of high-energy particle physics simulation. In this paper, we employ Comptonsoft 5.7.0 and Geant4 10.05.01. We construct a physical model of Xtend/SXI based on its specifications, as shown in table 1 . Simulation parameters are determined to reproduce the on-ground calibration of Xtend/SXI reported in Yoneyama