Wave Front Sensing demodulated at the difference frequency between two phase-modulation sidebands in a compound interferometer configuration for a gravitational-wave detector

Chiaki Hirose, Kenta Tanaka, Osamu Miyakawa, Takafumi Ushiba · 2025

Read Wave Front Sensing demodulated at the difference frequency between two phase-modulation sidebands in a compound interferometer configuration for a gravitational-wave detector by Chiaki Hirose, Kenta Tanaka, Osamu Miyakawa, Takafumi Ushiba (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-17893.txt.

Introduction

Chiaki Hirose and three co-authors propose a new alignment sensing method for laser gravitational wave detectors, where precise control of many optical axes is needed to keep the instrument locked. Standard wave front sensing is dominated by the main arm signal, hiding other axes.

Their method beats two modulated sidebands against each other and reads the signal at the difference frequency. Theory and a test on part of the KAGRA detector show that signals from the power recycling cavity and the incoming beam separate cleanly from the arm. Feedback using the method held a stable lock for over an hour.

Catalog record

CREATORChiaki Hirose, Kenta Tanaka, Osamu Miyakawa, Takafumi Ushiba
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE40 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2511-17893

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Wave Front Sensing demodulated at the difference frequency between two phase-modulation sidebands in a compound interferometer configuration for a gravitational-wave detector Chiaki Hirose, Kenta Tanaka, Osamu Miyakawa, Takafumi Ushiba Abstract Precise alignment sensing and control are essential for maintaining the stability of laser interferometric gravitational-wave detectors. Conventional Wave Front Sensing technique (WFS), which relies on the beat between the carrier and phase-modulated (PM) sidebands, is dominated by arm-axis signals when the carrier resonates in the full interferometer. This dominance limits the detection of other optical axes, such as the Power Recycling Cavity (PRC) and incident beam axes. To address this problem, we propose a novel sensing technique, “Phase-Modulated-sideband × \times Phase-Modulated-sideband Wave Front Sensing” (PMPMWFS), which demodulates the beat signal at the difference frequency between two anti-resonant PM sidebands. We derived the theoretical response of PMPMWFS and experimentally demonstrated it using the Power-Recycled X-arm (PRXARM) configuration of KAGRA. The results show that PMPMWFS effectively decouples angular fluctuation signals of the PRC and incident beam from those of the arm cavity and provides orthogonal signal components for the end mirror of the arm cavity. Furthermore, feedback control using PMPMWFS achieved stable interferometer locking for over one hour. These results demonstrate that PMPMWFS offers an effective sensing method for decoupling multiple alignment degrees of freedom in future gravitational-wave detectors. 2]Institute for Cosmic Ray Research (ICRR), KAGRA Observatory, The University of Tokyo, Kamioka-cho, Hida City, Gifu 506-1205, Japan PTEP-subject xxxx, xxx † † preprintnumber: XXXX-XXXX 1 Introduction. Gravitational Waves (GWs) are ripples in spacetime that propagate at the speed of light, generated by the accelerated motion of massive objects [ 1 ] . Observable GWs are emitted by astrophysical phenomena such as the mergers of compact binaries, the rotational motion of pulsars, and supernova explosions. The direct detection of these GWs is expected to yield significant scientific outcomes, including measurements of the Hubble constant [ 2 ] and the verification of general relativity [ 3 ] . This is achieved using laser interferometric GW detectors, each of which combines multiple optical resonators. Determining the direction of the GW source using laser interferometric GW detectors requires the detection of the time difference in the arrival of the GW at multiple detectors. As an example, on 14 August 2017, simultaneous GW observations were achieved for the first time by Advanced LIGO [ 4 ] and Advanced Virgo [ 5 ] , with greater precision than in previous observations [ 6 ] . Therefore, it is important to operate GW detectors stably over the long term. In laser interferometric GW detectors that incorporate multiple optical cavities, angular fluctuations of the mirrors constituting the interferometer can cause a relative misalignment between the incident beam axis and the resonant cavity axes, potentially reducing the stability of the interferometer. The interferometer stability can be improved by detecting this relative misalignment and feeding back to the mirror angles. Wave Front Sensing technique (WFS) is primarily employed to detect optical axis misalignment in interferometers [ 7 ] . The laser beam incident on the interferometer with multiple optical resonators is phase-modulated to generate sidebands using an Electro Optic Modulator (EOM). The beam reflected from the resonator is detected by a Quadrant Photo Diode (QPD). By demodulating the detection signal at the phase modulation frequency, the relative misalignment between the optical axis of the phase-modulated sideband (PM sideband) and that of the carrier is measured. Japanese GW detector KAGRA [ 8 ] conducted joint observations with LIGO during the fourth international collaborative GW observation run (O4a) [ 9 ] , from 24 May to 20 June 2023 (UTC). KAGRA employed a Power Recycled Fabry-Pérot Michelson Interferometer (PRFPMI) during O4a. The PRFPMI consists of a Fabry-Pérot Cavity (FPC) in each arm of the Michelson Interferometer(MI) called X- and Y- arm cavity, and the Power Recycling Mirror (PRM) recycles the light reflected from the interferometer. The Power Recycling Cavity (PRC) increases the intracavity power in the FPCs at both arms, reducing the shot noise that limits the sensitivity. The primary degrees of freedom of the optical axis in the PRFPMI are the FPC axes of both arms, the MI axis, the PRC axis, and the incident light axis. To reduce thermal noise, KAGRA adopts a large beam size on the FPC mirrors, making the optical axis more prone to tilting than in the other cavities. This FPC configuration is not unique to KAGRA but is also common to other large-scale laser interferometric GW detectors, such as LIGO and Virgo. When the carrier component resonates in the entire interferometer including the arm cavities, the WFS signal using the carrier detects changes in all axes. Consequently, the signal from the arm cavity makes it difficult to discern the signals from other axes in the WFS signal, because the arm cavity axis is the most sensitive to the angular motion of mirrors. As a result, it becomes difficult to stabilize the interferometer by feedback control. In the future, KAGRA will be upgraded to the Resonant Sideband Extraction (RSE) [ 10 ] to broaden the detection bandwidth for GW signals. Due to the increased number of degrees of freedom requiring control, this issue will become more pronounced, making signal separation crucial. In this paper, we propose a new alignment detection scheme, “Phase-Modulated-sideband \times Phase-Modulated-sideband Wave Front Sensing” (PMPMWFS), which uses the difference frequency of two PM sidebands. This method is designed to detect the optical axis difference between the cavity axis and the incident axis to the cavity by tuning PM sideband frequencies so that one of them resonates on the cavity and the other does not. Specifically, the two sidebands adopted here (Fig. 1 ) do not resonate in the arm cavities. Therefore, the ratio of the arm cavity axis fluctuation signal to the signals from other optical axes detected by the PMPMWFS is expected to be smaller than that in the WFS signal. If the PMPMWFS can achieve signal separation between the fluctuations of the incident beam and the PRC axis from those of the arm cavity, it will provide an effective means of alignment control to stabilize the interferometer. This paper summarizes the derivation of the PMPMWFS signal in Sec. 2 . In Section 3 , we present the results of measuring the PMPMWFS signal in the PRXARM, in which KAGRA’s PRC and X-arm cavity are resonant, and demonstrate alignment control of KAGRA’s interferometer using the PMPMWFS signal. Figure 1 : RSE schematic diagram in KAGRA. The incident light is split by a BS into the X- and Y-directions. FPCs are installed in both arms of the MI, referred to as the X- and Y-arm cavity. A PRM forms a PRC with the two input mirrors of the FPCs (ITMX and ITMY). Similarly, a Signal Recycling Mirror (SRM) forms a Signal Recycling Cavity (SRC) with the ITMs. The gravitational wave signal is detected at the SRC’s output port as a change in the optical path difference between the two arm cavities. Three PM sidebands are generated by the EOMs. The carrier beam resonates in both the PRC and the arm cavities. The PM sidebands f_{\mathrm{1}} , f_{\mathrm{2}} , and f_{\mathrm{3}} exhibit distinct resonance states: f_{\mathrm{1}} resonates with both the PRC and SRC, f_{\mathrm{2}} resonates only

Read the complete text