DoS Dos and Don’ts
Lucas Warwaruk, Konstantinos Zinelis, Randy H. Ewoldt, Christopher W. Macosko, Gareth H. McKinley · 2025
Read DoS Dos and Don’ts by Lucas Warwaruk, Konstantinos Zinelis, Randy H. Ewoldt, Christopher W. Macosko, Gareth H. McKinley (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-17360.txt.
Introduction
Lucas Warwaruk and four co-authors write a practical guide to dripping-onto-substrate rheometry, a technique that measures how stretchy low-viscosity liquids are by watching a thinning filament break. The method is established but lacked clear statements of what it can and cannot measure. The authors define operational limits for reading extensional viscosity directly from the filament's thinning rate, and model-based bounds for extracting viscosity and the extensional relaxation time.
Using dilute polymer solutions, they probe the smallest measurable relaxation times and show values as brief as a tenth of a millisecond can be resolved when two conditions hold. The two conditions involve the fluid's own timescales and the camera's capture rate, a new figure of merit they define. They also test sensitivity to nozzle size and gravity effects. The paper gives experimentalists a quantitative roadmap for trustworthy readings of weakly elastic fluids.
Catalog record
| CREATOR | Lucas Warwaruk, Konstantinos Zinelis, Randy H. Ewoldt, Christopher W. Macosko, Gareth H. McKinley |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 112 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2511-17360
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
DoS Dos and Don’ts Preprint: AIP/123-QED Lucas Warwaruk, Konstantinos Zinelis, Randy H. Ewoldt, Christopher W. Macosko, Gareth H. McKinley Abstract Dripping-onto-Substrate (DoS) rheometry is a well-established method for measuring the extensional rheology of low-viscosity liquids. However, clear guidelines on the capabilities and limitations of the technique are lacking. In the present work, we define operational limits for measuring a transient extensional viscosity directly from observation of the rate of filament thinning, as well as model-based bounds on calculating a viscosity η \eta and extensional relaxation time τ E \tau_{E} of a liquid using DoS. Dilute solutions of polyethylene oxide (PEO) and polyacrylamide (PAM) are used to probe the lower limit of measurable τ E \tau_{E} , demonstrating that values as low as 0.1 ms can be resolved, provided (a) the intrinsic Deborah number (based on the ratio of the relaxation time and the Rayleigh breakup time scale) is D e ≥ 𝒪 ( 0.1 ) De\geq\mathcal{O}(0.1) and (b) an instrumental constraint related to spatial and temporal resolution is satisfied. This instrumental constraint is quantified through a new metric we define as the filament capture rate , a “figure of merit” (expressed in Hz) that can be used to quantify the number of data points within the elasto-capillary regime that are available for extraction of τ E \tau_{E} . We also investigate the sensitivity to other experimental parameters including variations in nozzle radius and Bond number ( B o Bo ). Across the tested range ( 0.2 < B o < 0.7 0.2<Bo<0.7 ), extensional relaxation times for the same fluid vary by less than ± 16 \pm 16 %; however, experiments with low viscosity fluids at B o > 0.5 Bo>0.5 exhibit damped gravitational oscillations that affect early-time dynamics. Collectively, these results provide a quantitative roadmap for reliable DoS rheometry and affirm its use for measuring sub-millisecond relaxation times in weakly elastic fluids. I Introduction Adding a small amount of high molecular weight polymer to a Newtonian liquid can have an appreciable influence on the rheology of the resulting solution. In particular, dilute solutions of long chain polymers can exhibit an exceptionally large resistance to extensional deformation, despite having a shear viscosity comparable to the Newtonian solvent. The large extensional viscosity of dilute polymer solutions plays a critical role in a number of practical applications, for example, preventing mist formation of flammable hydrocarbon fuels [ 42 ] , or reducing drag in turbulent pipe flows [ 43 , 70 , 55 ] . A number of novel experimental techniques exist for measuring the extensional features of low viscosity non-Newtonian fluids, and have been reviewed in detail by 27 , 31 , 18 and 19 . For such materials, extensional rheometry techniques that rely on capillary forces to drive a filament thinning flow have become a preferred choice [ 58 , 11 , 36 , 22 , 56 ] . Viewed broadly, such techniques can be thought of as a quantitative version of the protorheological “thumb-and-forefinger test” [ 47 , 32 ] . One such technique, first demonstrated by 7 , then developed by 22 is known as Dripping-onto-Substrate (DoS) extensional rheology. This has proven to be an effective and relatively simple-to-implement method for measuring the extensional characteristics of dilute polymer solutions [ 64 , 21 , 57 , 62 ] . In DoS rheometry, a small drop of liquid is formed at the tip of a blunt-end nozzle and the pendant drop is slowly brought into contact with a hydrophilic substrate. Computational simulations demonstrate that the energy released by the pendant droplet spreading across a partially-wetting substrate drives a rapid initial neck formation [ 77 ] . Capillarity subsequently produces a strong transient extensional deformation in the thinning fluid ligament, especially in low viscosity fluids. High-speed digital imaging can be used to monitor the evolution in the filament radius R_{\mathrm{min}}(t) over time, from which the time-to-break t_{b} and extensional relaxation time \tau_{E} can be assessed [ 22 , 49 ] . If the liquid-vapour surface tension is known, the transient extensional viscosity \eta_{E}^{+}(t) , and the dynamic viscosity \eta (for Newtonian liquids) can be extracted [ 46 , 4 ] . Since its conception, numerous investigations have relied on DoS rheometry to measure the extensional characteristics of a variety of low viscosity fluids [ 20 , 59 , 44 , 41 , 57 , 74 , 75 ] . However, a clear set of experimental guidelines on the capabilities and limitations of DoS rheometry is lacking. Therefore, the goal of the current investigation, is to establish the key “Dos and Don’ts” of DoS rheometry; discussing critical parameters that influence the quality of the measurements and the accuracy of the resulting estimates of the extensional relaxation time. However, DoS rheometry is not the only capillarity-driven method for measuring the extensional relaxation time \tau_{E} , and this introduction will briefly summarize some of the other capillarity-driven approaches for measuring extensional rheology. The capillarity-driven thinning method based on a rapid initial plate separation (as implemented in the Capillary Break-up Extensional Rheometer or CaBER instrument) has been widely used for measuring a transient extensional viscosity and relaxation time of various dilute and semi-dilute polymer solutions [ 4 , 58 , 14 ] . In the CaBER device a liquid sample is first loaded between two circular plates to form a cylindrical liquid bridge. An axial step strain is then imposed on the sample by rapidly separating the plates apart from one another. Capillary forces drive the thinning, and ultimate break-up, of the unstable liquid bridge, producing a transient uniaxial extensional flow from which the time-to-break t_{b} , transient extensional viscosity \eta_{E}^{+} , and extensional relaxation time \tau_{E} can be extracted. 58 used scaling arguments to establish an “operability diagram” for CaBER, demonstrating that the technique can be used to measure relaxation times as small as \tau_{E}\approx 1 ms for low viscosity ( \eta<70 mPa s), aqueous polyethylene oxide (PEO) solutions. Since the work of 58 , a number of experimental works have developed new or modified capillarity-driven methods that are capable of measuring relaxation times less than 1 ms. For example, 11 measured relaxation times down to \tau_{E}=240 \text{\,}\mathrm{\SIUnitSymbolMicro s} using a modified CaBER approach known as the Slow Retraction Method (SRM) in which the plates are slowly separated at a constant velocity until the elongated liquid bridge crosses the static stability limit and rapidly fails. 37 measured relaxation times as small as \tau_{E}=60 \text{\,}\mathrm{\SIUnitSymbolMicro s} using a jet-based technique they christened Rayleigh Ohnesorge Jetting Extensional Rheometry (ROJER). The ROJER method, like DoS and CABER, relies on the Rayleigh-Plateau instability to drive filament thinning, but in an axially-perturbed fluid jet traveling at a high velocity. Subsequent to the work of 37 , an updated and more cost-effective ROJER design was developed by 30 . The recent development and growth of DoS rheometry has also produced a number of experimental investigations that have measured extensional relaxation times on the order of 10 \text{\,}\mathrm{\SIUnitSymbolMicro s} \leq\tau_{E}\leq 100 \text{\,}\mathrm{\SIUnitSymbolMicro s} [ 22 , 64 , 59 , 75 ] . The ability to make measurements of very small relaxation times in DoS, SRM and ROJER, is facilitated by the lack of fluid