Read Performance of the front-end electronics of the CMS electromagnetic calorimeter barrel for the High-Luminosity LHC by *, The CMS electromagnetic calorimeter group \note Corresponding authors: Chiara Basile [email protected], Federico Ferri [email protected]. \note Complete author list at the end of the document (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-17261.txt.

Introduction

The CMS Electromagnetic Calorimeter Group reports beam tests of upgraded readout electronics for one of the Large Hadron Collider's main detectors. The calorimeter measures electron and photon energies using lead tungstate crystals. Its front-end electronics are being rebuilt for the High-Luminosity phase of the collider, which will flood the detector with far more collisions. Prototypes of the new electronics were fitted to a small matrix of crystals and exposed to electron and pion beams at CERN.

Two test campaigns, in 2018 and 2021, used beam energies from 25 to 250 GeV. The constant term of the energy resolution came out better than six tenths of a percent, and timing resolution for energetic electrons was better than 30 picoseconds. Both figures meet the design requirements, clearing the upgrade for its demanding future environment.

Catalog record

CREATOR*, The CMS electromagnetic calorimeter group \note Corresponding authors: Chiara Basile [email protected], Federico Ferri [email protected]. \note Complete author list at the end of the document
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE49 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2511-17261

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Performance of the front-end electronics of the CMS electromagnetic calorimeter barrel for the High-Luminosity LHC *, The CMS electromagnetic calorimeter group \note Corresponding authors: Chiara Basile [email protected], Federico Ferri [email protected]. \note Complete author list at the end of the document Abstract The performance of the CMS electromagnetic calorimeter upgraded readout electronics, developed for the High-Luminosity phase of the LHC, is discussed. Data collected in two beam test campaigns conducted in 2018 and 2021 at the H4 and H2 beam lines of the CERN SPS are analyzed. Time and energy resolutions are measured on a 5 × 5 5\times 5 matrix of lead tungstate crystals equipped with prototypes of the new front end readout electronics, using electron and pion beams of energies spanning from 25 to 250 \GeV . In both campaigns the constant term of the energy resolution is measured to be better than 0.6% and the time resolution for electrons with energies above 50 \GeV is measured to be better than 30 ps , fulfilling the design requirements. \cmsNoteHeader ecal-tb-paper The CMS electromagnetic calorimeter group \hypersetup pdfauthor=The CMS electromagnetic calorimeter group,pdftitle=Performance of the front-end electronics of the CMS Electromagnetic Calorimeter barrel for the High-Luminosity LHC,pdfsubject=ECAL,pdfkeywords=CMS ECAL, electronics, calorimetry, HL-LHC keywords CMS experiment, CMS ECAL, electronics, calorimetry, High-Luminosity LHC 0.1 Introduction The Compact Muon Solenoid (CMS) apparatus [ 1 , 2 ] at the CERN Large Hadron Collider (LHC) is a multipurpose, nearly hermetic detector, designed to trigger on [ 3 , 4 , 5 ] and identify electrons, muons, photons, and (charged and neutral) hadrons [ 6 , 7 , 8 ] . Its central feature is a superconducting solenoid of 6 \unit m internal diameter and 12.5 \unit m length, providing a magnetic field of 3.8 \unit T. Within the solenoid volume are a silicon pixel and strip tracker, a lead tungstate crystal electromagnetic calorimeter (ECAL), and a brass and scintillator hadron calorimeter (HCAL), each composed of a barrel and two endcap sections. Forward calorimeters extend the pseudorapidity coverage provided by the barrel and endcap detectors. Muons are reconstructed using gas-ionization detectors embedded in the steel flux-return yoke outside the solenoid. More detailed descriptions of the CMS detector, together with a definition of the coordinate system used and the relevant kinematic variables, can be found in Refs. [ 1 , 2 ] . The CMS ECAL is a homogeneous and hermetic electromagnetic calorimeter made of lead tungstate (PbWO 4 ) scintillating crystals. The high density ( 8.28\unit{g/cm}^{3} ), short radiation length (8.9 \mm ), and small Molière radius (22 \mm ) of the PbWO 4 enabled the construction of a compact calorimeter with fine lateral granularity. The ECAL comprises a central barrel and two endcaps. The barrel, about 6 \unit m long and with an inner radius of about 1.3 \unit m, covers the pseudorapidity region \abs{\eta}<1.48 . It consists of 36 elements, known as supermodules (SM), arranged in two rings of 18, each covering half the length of the barrel. Each SM covers a range of 20\de in azimuthal angle ( \varphi ), as shown in the schematic drawing of figure 1 . Figure 1: A three dimensional view of the ECAL. In the barrel section, the cutaway views illustrate the disposition of modules within a supermodule and of crystals within a module. The endcaps are shown in grey as they will be replaced by a new subsystem as part of the upgrade for the high-luminosity LHC. The 61\,200 crystals in the barrel are arranged in a quasi-projective geometry, oriented toward the nominal interaction point, with their axis tilted by approximately 3\de in both \eta and \varphi . The crystals come in 17 different shapes, depending on their position along \eta . In the barrel, the emitted light is detected with avalanche photodiodes (APDs) operating at a gain of 50, corresponding to a bias voltage between 350 and 420 \unit V. A more detailed description of the ECAL, including the endcaps, can be found in Ref. [ 9 ] . The ECAL was designed to achieve an excellent energy resolution up to an integrated luminosity of 500 \fbinv over ten years of data taking at a peak luminosity of 1\times 10^{34}\percms . The performance of the LHC during Run- 2 and Run- 3 has exceeded the peak luminosity by more than a factor of two, with the ECAL continuing to deliver excellent results [ 2 , 10 ] . The High-Luminosity (HL) phase of the LHC, also called Phase- 2 of the LHC, is expected to deliver an integrated luminosity of 3000 \fbinv with radiation levels in the detector six times higher than the nominal LHC design [ 11 ] . To maintain the current performance in such a difficult environment the ECAL barrel must be upgraded [ 12 ] . The ECAL endcap, along with the entire CMS forward calorimetry, will be completely replaced by a silicon-based high-granularity calorimeter [ 13 ] . This paper presents the results of studies of the performance of the upgraded electronics for the ECAL, made with a 5\times 5 matrix of \text{PbWO}_{4} crystals and high energy electron or pion beams. The data were collected in separate campaigns, in 2018 and 2021, in the H4 and H2 test beams at the CERN SPS. In the following, the current electronics is referred to as the “legacy electronics” and the upgraded version as the “Phase- 2 electronics”. Section 0.2 generally describes the ECAL barrel upgrade for HL-LHC, and details the components of the Phase- 2 electronics. Section 0.3 describes the experimental setup of the beam test campaigns. The strategy and the results for the signal reconstruction are detailed in section 0.4 , 0.5 , and 0.6 . Finally, the results concerning time and energy resolution measurements are presented in section 0.7 . 0.2 The upgrade of the CMS electromagnetic calorimeter The primary predicted effects of operating at HL-LHC luminosities include a decrease in the light transmission of the PbWO 4 crystals, caused by irreversible radiation damage of the crystal lattice, and an increase of the APD leakage current, due to bulk damage in the silicon. These effects contribute to a reduction in the signal to noise ratio. Studies have been conducted to assess the impact of the radiation on crystals and photodetectors, demonstrating that both components can be successfully operated up to the end of HL-LHC [ 14 ] . To mitigate the increase in the bulk current of the APDs, the operating temperature will be lowered from the current 18 \,{}^{\circ}\text{C} to 9 \,{}^{\circ}\text{C} . This will not require modification to the existing on-detector cooling services. To cope with higher trigger rates, improve the rejection of signals from direct ionization of the APDs (spikes), and mitigate the effect of additional interactions within the same or neighbouring bunch crossings (in-time and out-of-time pileup, respectively), the front-end and back-end ECAL barrel readout electronics will be replaced during the Long Shutdown 3 of the LHC, which is scheduled from 2026 to 2029. 0.2.1 Readout electronics Figure 2: Layout of the main components of a readout unit of the legacy electronics (left) and of the Phase- 2 electronics (right). The motherboards–not shown in here–are located parallel to the FE boards, between the crystals and the 5

Read the complete text