The SABRE South Experiment at the Stawell Underground Physics Laboratory

* · 2025

Read The SABRE South Experiment at the Stawell Underground Physics Laboratory by * (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-16451.txt.

Introduction

L. J. Milligan reports the status of the SABRE South dark matter test at an underground laboratory in Australia. SABRE tests a long standing claimed seasonal signal from an Italian sensor using ultra pure sodium iodide crystals. A southern hemisphere twin can split seasonal site effects from a true dark matter modulation. Crystals sit inside a liquid scintillator veto with passive shielding and a muon veto.

The underground facility lies more than a kilometer deep in a former mine. Background from sensor solids has been assessed and mitigated in detail. Crystal and veto performance are characterized before full science running. Assembly was nearing completion with first subsystems installed. The proceedings update the community on expected sensitivity and readiness.

Catalog record

CREATOR*
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE14 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2511-16451

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

The SABRE South Experiment at the Stawell Underground Physics Laboratory * Abstract SABRE aims to provide a test of the signal observed by DAMA/LIBRA through two separate detectors that rely on joint ultra-high NaI(Tl) purity crystal R&D activities: SABRE South at SUPL Australia and SABRE North at LNGS Italy. SABRE South is designed to disentangle seasonal and site-related effects from the dark matter-like modulated signal. Ultra-high purity crystals are immersed in a liquid scintillator veto, further surrounded by passive shielding and a plastic scintillator muon veto. Significant work has been undertaken to assess and mitigate background from the detector materials, and to understand the performance of both the crystal and veto systems. SUPL is a newly built facility located 1024 m underground in Australia. SABRE South is currently being assembled and will be completed in 2025, with first subsystems already installed in SUPL. This proceedings will report on the general status of the SABRE South assembly, its expected performance, and the design of SUPL. [a,b]L. J. Milligan on behalf of the SABRE South Collaboration 1 Introduction To date, the only reported direct detection of dark matter (DM) has come from the DAMA/LIBRA experiment, which claims to observe an annually modulating nuclear recoil rate with a NaI(Tl) target. This annual modulation is expected to arise from the relative motion of the Earth around the Sun, and the Sun around the galactic centre, such that a scattering rate increases as the Earth moves into the DM halo, and vice-versa as it moves away. DAMA/LIBRA has observed their reported signal for 20 years in the 2-6 keV ee region at a significance of 12.4 \sigma , and recently also in the 1-6 keV ee region at 11.6 \sigma [ 5 ] . Modulating annually, the reported signal has a period of 1 year ( t_{0}=152.5 days) that peaks on June 2nd with a very low modulation amplitude of \sim 0.01 cpd/kg/keV ee . This result remains unverified, and is in tension with limits imposed by other direct detection experiments (such as LXe based detectors) in the same mass regime [ 8 ] . To reliably test this result in a model-independent way, any such detector would need to use the same target material. The SABRE South experiment is the Southern Hemisphere component of the SABRE Experiment, which aims to test the modulating signal observed by the DAMA/LIBRA experiment using ultra-pure NaI(Tl). Being located in the Southern Hemisphere uniquely allows the disentanglement of seasonal and site-related effects from the DM-like modulated signal, due to the seasonal shift relative to the Northern Hemisphere. The SABRE South detector will be located in the Stawell Underground Physics Laboratory (SUPL), which is the first underground laboratory in the Southern Hemisphere. Installation of SABRE South subsystems in SUPL has already begun, and assembly of the full detector is expected to be completed in 2025. 2 The SABRE South Detector The SABRE South detector is composed of three subdetectors: an array of seven ultra-pure NaI(Tl) crystals enclosed in oxygen free high thermal conductivity (OFHC) copper enclosures, a linear alkylbenzene (LAB) based liquid scintillator (LS) veto, and a 9.6 m 2 dedicated muon veto. Surrounding the detector is passive steel and high density polyethylene shielding, in which the latter is sandwiched between the former. Figure 1 depicts the full detector system. Figure 1: Left: A labelled render of the SABRE South detector system, including shielding. Left of the detector is an enlarged version of the crystal enclosure, labelling its key components. Right: The total experimental background for SABRE South as a function of energy. The seven crystals will sum to a total mass of between 35 to 50 kg, depending on whether the crystals are grown with SICCAS by the seedless Bridgman method ( 7\times 7 kg crystals) or by RMD using a combination of the vertical Bridgman method and a zone-refining technique ( 7\times 5 kg crystals). As we expect the smaller crystals to have a lower background rate due to zone-refining, the expected sensitivity of SABRE South should not be drastically changed [ 9 ] . Test crystals have been measured to have extremely high purity levels [ 3 ] . A single crystal enclosure contains one ultra-pure crystal directly coupled to two Hamamatsu 7.62 cm R11065 photomultiplier tubes (PMTs), and is continuously purged with high purity nitrogen. These PMTs have been rigorously pre-calibrated, so to understand the future performance of each detector. The enclosure is suspended in the LS by an OFHC copper conduit. A remotely operated radioactive calibration system for the crystal arrays has been designed [ 9 ] . The crystal detectors are expected to have a 1 keV ee threshold, such that the 1-6 keV ee region of interest can be probed. The active LS veto is a key feature of the SABRE South detector. Its main requirements are to veto extrinsic and key intrinsic crystal backgrounds, particularly the 40 K impurity which decays an Auger electron right in the 1-6 kev ee region of interest, and a gamma ray that can be tagged by the veto. Simulations of the SABRE South experimental background indicate that the 40 K background in the crystal can be reduced by a factor of \sim 10 by the LS veto, with a veto efficiency of 27% with respect to the total experimental background — meaning <10 % of the total background is external to the crystals [ 4 ] . This subdetector can also be used for background characterisation, both particle identification and position reconstruction, providing an avenue for understanding what type of background processes may produce a DAMA/LIBRA like modulation. The LS veto is composed of 12,000 L of LAB sourced from the supplier to the JUNO experiment [ 1 ] , doped with approximately 3.5 g/L of PPO and 15 mg/L of bis-MSB. At least 18 oilproof Hamamatsu 20.2 cm R5912 PMTs will be installed along the walls of the vessel, which will be covered in reflective PET Lumirror sheets to increase photon detection efficiency. This could be increased to 32, augmented with decommissioned PMTs from the Daya Bay experiment, thus improving the photosensor coverage of the detector and the effectiveness of reconstruction techniques. Preliminary quality assurance tests have been performed on the 16 PMTs receieved from Daya Bay, with current results indicating 14 are suitable for use in the LS veto, whilst the remaining 18 have been undergone pre-calibration tests. A threshold of 50 keV is possible for this subdetector, which is equal to approximately 10 photoelectrons (PEs), where each PMT is expected to be detecting 1-2 PEs. As a result, thorough pre-calibration of all R5912 PMTs to be used in this system is imperative. The LS veto is calibrated remotely with a radioactive calibration system, and an optical calibration system that allows for remote characterisation/monitoring of PMT properties throughout the lifetime of the experiment. The muon veto sits above the shielding of the detector, and consists of eight panels of EJ-200 plastic scintillator with two Hamamatsu R13089 PMTs coupled to either end. This detector can be used in coincidence with the LS veto to improve background reconstruction, but is also capable of position reconstruction along the length of each panel to a resolution of 5

Read the complete text