Bidimensional measurements of photon statistics within a multimodal temporal framework
C. Hainaut, K. Ouahrouche, A. Rançon, G. Patera, C. Ouarkoub, M. Le Parquier, P. Suret, A. Amo · 2025
Read Bidimensional measurements of photon statistics within a multimodal temporal framework by C. Hainaut, K. Ouahrouche, A. Rançon, G. Patera, C. Ouarkoub, M. Le Parquier, P. Suret, A. Amo (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-11403.txt.
Introduction
C. Hainaut, K. Ouahrouche, and their colleagues show a way to map photon counts across a surface in a single shot, with timing as fine as a picosecond. Photon counts show how light behaves when it is out of balance or changing fast. Mapping them in two dimensions at such speed is hard to do well.
Their setup uses a crystal that mixes light waves to read the counts. It can tell apart two basic kinds of light, coherent and thermal, across the surface. The counts found depart from the ideal shapes. The team traces that gap to vacuum noise and to how the amplifier reacts. A mode-based frame for the timing explains the gap and matches the data.
Catalog record
| CREATOR | C. Hainaut, K. Ouahrouche, A. Rançon, G. Patera, C. Ouarkoub, M. Le Parquier, P. Suret, A. Amo |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 78 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2511-11403
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Bidimensional measurements of photon statistics within a multimodal temporal framework C. Hainaut, K. Ouahrouche, A. Rançon, G. Patera, C. Ouarkoub, M. Le Parquier, P. Suret, A. Amo Abstract Ultrafast imaging of photon statistics in two dimensions is a powerful tool for probing non-equilibrium and transient optical phenomena, yet it remains experimentally challenging due to the simultaneous need for high temporal resolution and statistical fidelity. In this work, we demonstrate spatially resolved single-shot measurements of photon number distributions using difference-frequency generation (DFG) in a nonlinear BBO crystal. We show that our platform can discriminate between coherent and thermal photon statistics across two spatial dimensions with picosecond resolution. At the same time, we find that the retrieved distributions deviate from the ideal ones, a consequence of vacuum contamination and the multimodal response of the amplifier. To explain this, we develop a temporal mode decomposition framework that captures the essential physics of signal amplification and fluorescence, and quantitatively reproduces the experimental findings. This establishes a robust approach for measuring two-dimensional photon statistics while clarifying the fundamental factors that limit the fidelity of such measurements. I Introduction For decades, researchers have sought the ability to faithfully image spatial bi-dimensional information generated at incredibly fast timescales. Ultrafast chaotic behaviors, complex nonlinear optical phenomena, and rapid biological processes like protein rearrangement are just a few examples of events that occur on timescales ranging from picoseconds to femtoseconds. Additionally, transient events, specific to two-dimensional systems, reflect many major fundamental mechanisms occurring in biology, physics, or chemistry 8 ; 23 ; 26 . Traditionally, pump-probe methods 25 ; 53 ; 3 ; 19 ; 29 ; 50 ; 9 ; 24 ; 55 have been used to capture these fast dynamics through repeated measurements. However, many ultrafast phenomena are either non-repetitive or challenging to reproduce 27 ; 46 ; 39 ; 48 ; 45 ; 43 . Significant efforts have been made to create platforms capable of performing ultrafast single-shot optical measurements 32 ; 21 ; 28 , intending to be free of the paradigmatic repeatable measurement schemes. The main objective of these platforms is the possibility of measuring bi-dimensional photonic fields, at an ultrafast scale (picosecond to femtosecond information with high repetition rate) without alteration of the information of interest. Well-established strategies consist of using cutting-edge pulsed laser technologies to probe a system with strong optical pulses to have enough signal-to-noise ratio in a single-shot experiment and then retrieving the information of interest with various elaborated methods 51 ; 2 ; 31 ; 34 ; 54 ; 18 An important strategy to realize ultrafast sampling and perform single-shot measurements is based on the use of highly nonlinear optical processes such as Sum-Frequency Generation (SFG) or Difference-Frequency Generation (DFG), driven by a strong ultrashort pulse in bulk nonlinear materials. Both processes convert the information contained in a 2D optical field to another wavelength and sample it on an ultrafast timescale determined by the pulse duration. The key distinction between the two methods lies in their respective properties: DFG can amplify the signal but introduces a fluorescence background, while SFG is background-free without vacuum contamination when reaching 100 \% conversion efficiency 17 . As a result, SFG is typically preferred for relatively strong input signals, where the signal significantly exceeds the dark count and readout noise of conventional detectors. In contrast, DFG is better suited for weak input signals due to its gain capabilities. While DFG-based bi-dimensional imaging has been demonstrated 16 ; 49 , no focus has been set on the influence of the nonlinear effects and vacuum contamination on the spatial statistical distributions of photon counts in single-shot images. A system capable of extracting this information with high fidelity would enable the evaluation of bi-dimensional intensity correlation functions, providing additional information on ultrafast 2D phenomena. In this study, we explore these questions by using parametric down-conversion to perform time sampling within a picosecond window of a two-dimensional image. Through a quantitative analysis of the system response, we demonstrate that the concept of temporal modes, originating from quantum optics and describing the response of nonlinear pulsed systems, serves as an effective framework to understand the system’s behavior. We further analyze the behavior of amplified vacuum fluctuations (i.e., fluorescence) and examine how known input 2D signals with distinct photon statistical distributions are altered by the DFG process. Finally, we provide detailed experimental analysis, theory and numerical investigation to explain quantitatively why the measurements deviate from the statistics of the input field due to fundamental vacuum contamination as well as due to the multimodal temporal response of the system. We obtain predictions that match the experimental data remarkably. This work provides a comprehensive analysis of the 2D photon distribution imaging framework using the DFG scheme. The paper is organized as follows. In the first part, we present two-dimensional single-shot measurements of photon statistics using coherent and thermal input states, showing that the system is capable of faithfully imaging complex spatial patterns while preserving qualitative differences between the two types of photon states. We then highlight the quantitative deviations of the measured statistics from the ideal photon distributions and identify their origin in vacuum contamination and the multimodal response of the nonlinear amplifier. In the second part, we introduce a theoretical and numerical framework based on temporal mode decomposition, which provides a quantitative understanding of the system’s response. Starting from a simplified plane-wave configuration, we validate the multimodal description by comparing its predictions with experiments performed with vacuum, coherent, and thermal input states. Finally, we extend this approach to the two-dimensional configuration, demonstrating that the model accurately accounts for the measured distributions, which establishes a comprehensive framework for DFG-based ultrafast-photon statistics imaging. II 2D photon statistics measurements The system under study consists of a bulk material with second-order nonlinearity \chi^{(2)} , namely, a Beta Barium Borate (BBO) crystal of length l_{c}=2 mm, interacting with two optical fields. A strong picosecond pulsed field ( \approx 0.1 mJ per pulse), referred to as the pump, with a wavelength \lambda_{\text{p}}=400 nm ( \omega_{\text{p}}=2\pi\times 749.2 THz) and a continuous-wave signal at \lambda_{\text{s}}=840.1 nm ( \omega_{\text{s}}=2\pi\times 356.7 THz) are spatially overlapped within the crystal. By appropriately selecting the phase-matching angle of the crystal, part of the pump field at 400 nm converts and amplifies the signal field at \lambda_{\text{s}}=840.1 nm and an idler field centered at \lambda_{\text{i}}=763.3 nm ( \omega_{\text{i}}=2\pi\times 392.5 THz) is generated via Difference-Frequency Generation (DFG), see level scheme in Fig. 1 . The idler field is an amplified replica of the signal field. The crystal and strong pump beam act as a phase-insensitive amplifier, meaning that the gain is independent of the phase of the input signal field. The ultrafast nature of this scheme stems from the ability to utilize a picosecond pulsed pump to achieve the conversion, allowing for the sampling of picosecond-scale temporal information from the signal field and transferring it into the idler field through stimulated parametric amplification. However, in addition to the signal and idler fields, the pump spontaneously amplifies vacuum fluctuations at the wavelength of both signal and idler. As we will see, these spontaneous fluorescence photons will have an important effect in the measurement of photon distributions of the photon field. II.1 Experimental setup and imaging Figure