Temperature Dependence of the Time Resolution in a SiPM-Readout Plastic Scintillator for Cosmic–Ray Applications Journal: Nuclear Instruments and Methods in Physics Research - section A

José Reyes Castillo, Saúl Aguilar Salazar, Diego Mauricio Gomez Coral · 2025

Read Temperature Dependence of the Time Resolution in a SiPM-Readout Plastic Scintillator for Cosmic–Ray Applications Journal: Nuclear Instruments and Methods in Physics Research - section A by José Reyes Castillo, Saúl Aguilar Salazar, Diego Mauricio Gomez Coral (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-10041.txt.

Introduction

José Reyes Castillo, Saúl Aguilar Salazar, and Diego Mauricio Gomez Coral test how temperature affects the timing precision of a plastic scintillator detector read out by silicon photomultipliers. Balloon and space cosmic-ray devices rely on such detectors for picosecond-level timing used in triggering and particle ID, and flight temperatures swing widely. Their prototype pairs a BC418 scintillator bar with Onsemi sensors inside a controlled thermal chamber.

Electrons from a strontium-90 source served as the test beam, with a dedicated differential preamplifier and coincidence triggering. The best time resolution reached was about 160 picoseconds at three volts of overvoltage. Crucially, that resolution stayed stable from minus twenty to plus twenty degrees Celsius and uniform along the bar, which is what flight devices need.

Catalog record

CREATORJosé Reyes Castillo, Saúl Aguilar Salazar, Diego Mauricio Gomez Coral
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE24 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2511-10041

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Temperature Dependence of the Time Resolution in a SiPM-Readout Plastic Scintillator for Cosmic–Ray Applications Journal: Nuclear Instruments and Methods in Physics Research - section A José Reyes Castillo, Saúl Aguilar Salazar, Diego Mauricio Gomez Coral Abstract Balloon- and space-borne cosmic–ray experiments employ plastic scintillators read out by silicon photomultipliers (SiPMs) to achieve picosecond–level time resolutions for triggering and particle identification. The performance of these systems can be affected by temperature variations encountered in flight. In this work, a time–of–flight (TOF) prototype consisting of a BC418 plastic scintillator bar coupled to Onsemi MICROFC-30050 SiPMs was constructed and tested under a controlled thermal environment between –20 and 20 °C. Electrons from a Sr 90 {}^{90}\text{Sr} source were used as a beam, and a dedicated differential preamplifier and coincidence triggering were implemented to study the detector response. A minimum time resolution of 160 ps was achieved at an overvoltage of 3 V, remaining stable across the tested temperature range and uniform along the scintillator bar. 1 Introduction 1.1 Motivation The direct detection of cosmic rays has entered a precision measurement era, with experiments in space such as AMS-02 [ 10 ] , CALET [ 2 ] , and DAMPE [ 12 ] on the International Space Station reporting uncertainties on the level of a few percent. Their time–of–flight (TOF) or Plastic Scintillator Detector (PSD) systems, equipped with photomultiplier tubes (PMTs), are used for triggering and particle identification, achieving time resolutions of hundreds of picoseconds (ps) in AMS-02. Currently, new balloon–borne experiments are being deployed, such as GAPS [ 8 ] for antinuclei detection and HELIX [ 26 ] for light–isotope identification, which include Silicon Photomultipliers (SiPMs) in their TOF systems, improving time resolution. Moreover, forthcoming experiments such as HERD [ 35 ] will extend detection capabilities for high-energy cosmic rays near the knee, with improved timing layers and the use of plastic fibers and SiPMs for particle tracking. CubeSat projects are also testing lightweight scintillator–SiPM assemblies as cost–effective payloads for high-altitude orbits [ 34 ] . In addition, planned next–generation experiments such as ALADInO [ 3 ] and AMS-100 [ 28 ] have more ambitious goals, aiming to be located at Lagrange Point L2, and to achieve time resolution on the order of a few tens of picoseconds. These experiments attempt to extend measurements of cosmic–ray fluxes and composition with unprecedented precision, requiring detectors capable of operating reliably in the harsh conditions of near space. Compact, low–power, and efficient systems of plastic scintillators coupled to SiPMs are therefore of significant interest in this field and require a detailed study. Improved timing capabilities are essential for accurate reconstruction of particle velocity and for identification of particle species through TOF techniques. It is known that fast plastic scintillators are the best active material for TOF detectors due to their short decay times and high light yields, two crucial parameters affecting time resolution [ 18 ] . When coupled to SiPMs, these detectors offer significant advantages in time resolution over traditional PMTs, thanks to their fast response, high gain, and high efficiency. They also show substantial benefits for space and balloon missions, including low operating voltages, immunity to magnetic fields, mechanical robustness, and rapidly decreasing costs [ 16 ] . 1.2 Silicon Photomultipliers (SiPMs) A silicon photomultiplier (SiPM) is a solid–state device composed of hundreds or thousands of Geiger–mode avalanche photo–diodes (micro–cells), which produce a fast signal when one or multiple photons hit it [ 27 ] . The breakdown voltage ( \text{V}_{\text{bd}} ) corresponds to the reverse–bias voltage ( \text{V}_{\text{bias}} ) at which Geiger-mode avalanche multiplication begins in the micro–cells and depends on the internal structure [ 16 , 1 ] . The overvoltage ( \text{V}_{\text{ov}} ) is the excess bias voltage above the breakdown voltage, which determines the strength of the electric field in the avalanche region ( \text{V}_{\text{ov}}=\text{V}_{bias}-\text{V}_{\text{bd}} ). It governs the main performance parameters of the device, including gain ( G ), photon detection efficiency (PDE), and correlated noise. Increasing the overvoltage raises the gain, increases trigger avalanche probability, resulting in a higher PDE and an increased noise signal. The gain is defined as the amount of charge flowing per avalanche and is expressed as G=C_{cell}\text{V}_{\text{ov}}/e=C_{cell}(\text{V}_{bias}-\text{V}_{\text{bd}})/e , where C_{cell} is the effective capacitance of a micro-cell. The total output signal is the sum of the responses from all fired micro–cells, yielding a gain comparable to PMTs ( 10^{5}-10^{6} ). The gain stability depends directly on maintaining a constant overvoltage. Thus, temperature–induced changes in breakdown voltage must be compensated to keep G constant. Due to their inherent solid-state nature, SiPMs are affected by thermal conditions. In particular, an average current due to thermally induced avalanches, called dark current, is present. The dark count rate (DCR) quantifies the corresponding number of individual dark pulses detected per second. An important characteristic of SiPMs for TOF detectors is the fast internal avalanche amplification, which provides excellent timing information for the photon’s arrival at the photodetector. In this work, we present an experimental study of the time resolution of a plastic scintillator detector prototype read out by SiPMs, focusing on its performance under different thermal conditions. In Section 2 , the experimental setup is introduced, and in Section 3 , the measurement results and analysis are presented. Conclusions are summarized in Section 4 . 2 Experimental setup Two types of experimental setups were used in this work. On the one hand, a setup was designed to study the variation of the SiPM’s breakdown voltage with temperature and the time resolution of the TOF counter as a function of temperature (Setup 1). On the other hand, the time resolution as a function of the source position in the TOF counter at room temperature was investigated with a slightly different arrangement (Setup 2). In both cases, four Onsemi MICROFC-30050-SMT [ 23 ] SiPMs, soldered to a PCB in an array, were used as photodetectors. An external high-precision power supply, Keithley 2280S-60-3 [ 29 ] , provided the bias voltage for the four SiPMs. A fast–timing plastic scintillator bar BC-418 [ 19 ] , labeled P1, with dimensions 100 mm in length, 16 mm in width, and 3 mm in thickness, was tested. The bar was optically coupled to the array of four SiPMs with optical grease and wrapped with Tyvek ® and black tape. A second small plastic scintillator bar, labeled P2, of the same reference as P1, was coupled to a Photomultiplier Hamamatsu R14755U-100 [ 17 ] , and positioned just below P1. The signal from the PMT in coincidence with a SiPM’s signal acted as a trigger, as shown in Figure 1 (a). An electron source ( {}^{90}\text{Sr} ) with a collimator of 1 mm diameter was put above P1 and P2 and used as a beam to test the counter (see Figure 1 (a)). Electrons from {}^{90}\text{Sr} and its daughter {}^{90}\text{Y} have a continuous energy spectrum up to 2.2 MeV, and can be considered MIPs in plastic scintillator above 1 MeV [ 9 ] . Figure 1: (a) Diagram of the different experimental setups used in this work. (b) Photograph of the cooling system used in Setup 1. See text for details. 2.1 Setup 1: Temperature Dependence The cooling system is integrated by a Peltier module

Read the complete text