Cold-Atom Buoy: A Differential Magnetic Sensing Technique in Cold Quadrupole Traps

Árpád Kurkó, Dávid Nagy, Alexandra Simon, Thomas W. Clark, András Dombi, Dániel Varga, Francis B. Williams, József Fortágh, Peter Domokos, András Vukics · 2025

Read Cold-Atom Buoy: A Differential Magnetic Sensing Technique in Cold Quadrupole Traps by Árpád Kurkó, Dávid Nagy, Alexandra Simon, Thomas W. Clark, András Dombi, Dániel Varga, Francis B. Williams, József Fortágh, Peter Domokos, András Vukics (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-08797.txt.

Introduction

Árpád Kurkó and nine co-authors turn a trapped cloud of cold atoms into a magnetic compass. In a quadrupole trap, an outside uniform field pushes the trap center sideways by an amount that grows with the field. The atom cloud follows, so the cloud's position itself reports the field.

Flipping the quadrupole polarity between shots and comparing cloud positions cancels shared disturbances such as gravity and weak field unevenness. The remaining differential signal points along the external field and needs only absorption imaging, no spectroscopy. With micron-level position resolution the authors estimate sensitivity near the milli-Gauss level. The technique targets field compensation inside sensitive experiments and bridges the range between Earth-strength fields and precision atomic magnetometry. A three-dimensional version needs only minor additions.

Catalog record

CREATORÁrpád Kurkó, Dávid Nagy, Alexandra Simon, Thomas W. Clark, András Dombi, Dániel Varga, Francis B. Williams, József Fortágh, Peter Domokos, András Vukics
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE35 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2511-08797

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Cold-Atom Buoy: A Differential Magnetic Sensing Technique in Cold Quadrupole Traps Árpád Kurkó, Dávid Nagy, Alexandra Simon, Thomas W. Clark, András Dombi, Dániel Varga, Francis B. Williams, József Fortágh, Peter Domokos, András Vukics Abstract We present a technique for vectorial magnetic sensing using a cold-atom cloud trapped in a magnetic quadrupole. The center of the trapped cloud is determined by absorption imaging and compared for opposite polarities of the quadrupole. In the presence of an external magnetic field, the displacement of the cloud depends on both the field’s direction and magnitude. By analyzing this shift under polarity reversal, we infer the two transverse components of a homogeneous external magnetic field relative to the imaging axis, without requiring spectroscopic interrogation. Assuming micron-scale position sensitivity and typical magnetic field gradients, the method enables resolution at the milli-Gauss level. It is compatible with standard cold-atom setups and offers a practical tool for field compensation in magnetically sensitive experimental stages. As such, it establishes a bridge between traditional macroscopic magnetic field probes and atomic-physics-based precision sensors. keywords cold atoms, quantum sensing, magnetic trapping, magnetic sensing, differential metrology 1 Introduction Magnetic trapping is a foundational technique in cold-atom physics, enabling conservative, long-duration confinement of neutral atoms in magnetically sensitive internal states 35 . Following the advent of magneto-optical traps (MOTs) 39 , the development of purely magnetic traps allowed atomic ensembles to be held and manipulated without continuous optical scattering. This led to the first observations of Bose–Einstein condensation 3 ; 14 and has since underpinned advances in quantum simulation, interferometry, and hybrid quantum systems 8 ; 26 ; 50 . The canonical magnetic trap geometries – such as the quadrupole and the Ioffe–Pritchard configuration – are typically realized using either macroscopic coils mounted near or inside the vacuum chamber, or micrometer-scale current paths on atom chips 38 ; 42 ; 20 . These setups exploit the spatial dependence of the magnetic field near the trap center to create a potential minimum for low-field-seeking Zeeman states. A central advantage of such magnetic traps is that they are easy to configure (e.g. displace) via the feed current of the electromagnets 21 ; 22 ; 19 ; 31 . Atomic systems account for some of the most sensitive 28 ; 13 ; 46 and accurate 18 means of magnetic field measurement, having become competitive with superconducting quantum interference devices 9 . These sensors rely on the internal degrees of freedom of atoms – typically hyperfine Zeeman sublevels – and detect magnetic fields through their influence on atomic spin precession via the optical response 10 . A wide variety of architectures exist, from thermal atomic beams in early precision experiments 40 , to spin-exchange relaxation-free magnetometers based on alkali vapors 5 ; 27 ; 11 ; 2 ; 45 . More recently, to laser-cooled atomic ensembles in vacuo 49 ; 1 , all-optical multi-axis measurement 30 ; and all-optical, multi-dimensional magnetic measurement using spatially shaped beams 12 . In this work, we introduce a technique for magnetic field sensing based on the spatial displacement of a cold-atom cloud held in a magnetic quadrupole trap and manipulated exclusively with changes in current. By alternating the polarity of the quadrupole field between consecutive experimental shots, we generate a symmetric displacement response of the trap center in the presence of an external homogeneous magnetic field. This effect is measured using absorption imaging and two-dimensional Gaussian fitting of the atom cloud’s optical depth profile. The method is remarkably simple: it relies solely on spatial degrees of freedom and requires no spectroscopic interrogation, microwave fields, or internal-state coherence – making it broadly applicable in settings where magnetic field control is critical but conventional magnetometry is impractical, as for magnetic compensation in cold-atom preparation stages. We show that this approach enables vectorial detection of stray magnetic fields transverse to the imaging axis with milli-Gauss-level sensitivity, using standard cold-atom infrastructure. Relying on just a single imaging beam, the method can facilitate portable 7 ; 17 and miniature 37 ; 36 ; 34 devices in cold-atom-based quantum technologies. The strategy of reversing a controlled experimental parameter to reveal or isolate physical effects is a cornerstone of precision metrology. It appears across a wide range of domains: in spin-echo and Ramsey spectroscopy sequences that cancel quasi-static dephasing 23 ; 41 ; in electric dipole moment searches where field polarity is flipped to isolate parity-violating signatures 44 ; and in Pound-Drever-Hall spectroscopy 16 where opposite-sign phase shifts of sidebands cancel in the midpoint of a spectral feature. These differential schemes amplify antisymmetric responses while canceling common-mode drifts and offsets, enabling high-precision measurements in the presence of substantial technical noise. The cold-atom buoy technique follows this paradigm by alternating the sign of the quadrupole gradient between consecutive experimental shots to reverse the geometric response of the trap to external homogeneous magnetic fields. The resulting displacement difference forms a direct observable that scales linearly with the external field. 2 Concept 2.1 Scheme The potential in a magnetic trap acting on an atom in a magnetic sublevel m_{F} reads: U(\mathbf{r})=\mu_{\text{B}}g_{F}m_{F}\absolutevalue{\vb{B}(\vb{r})}, (1) where \mu_{\text{B}} is the Bohr magneton, and g_{F} is the hyperfine Landé g-factor. The potential being proportional to the modulus of the magnetic field shows that the trapping is independent of the polarity of the quadrupole, in sharp contrast to the MOT stage, where the quadrupole polarity has to match the polarization of the inbound MOT beams. The response to a homogeneous field, on the other hand, does depend on the quadrupole polarity, and is opposite for opposite quadrupole polarities, forming the basis of the buoy effect. This can be seen by writing the quadrupole field in the following form: \mathbf{B}_{\text{Q}}(\mathbf{r})=Q\,\quantity(\vb{x} + \vb{y} - 2\vb{z}),\quad Q\equiv\hat{\mathbf{x}}\cdot\partial_{x}\mathbf{B}(\mathbf{r})\big|_{\mathbf{r}=\epsilon\hat{\mathbf{x}}} (2) where Q is the strength of the quadrupole, considered a signed scalar quantity, that can be expressed via the gradient of the field in one of the Cartesian directions at an infinitesimal distance \epsilon from the center. This is a good approximation of the magnetic field of a coil pair with opposite driving currents in the vicinity of the geometrical midpoint between the coils, cf. section 3.4 . While this form of the field leads to a potential with its minimum at \mathbf{r}=0 , where \mathbf{B}_{\text{Q}}=0 , the superposition of a homogeneous external field \mathbf{B}_{\text{ext}} displaces this zero-field point to \mathbf{r}_{0}=\frac{\quantity[ \hat{\vb z}\circ\hat{\vb z} - 2 \qty(\hat{\vb x}\circ\hat{\vb x} + \hat{\vb y}\circ\hat{\vb y} ) ]\,\mathbf{B}_{\text{ext}}}{2Q}, (3) changing sign with Q . The sign of Q corresponds to the quadrupole polarity: positive when the axial field gradient points inward along +z , and negative otherwise. Assuming perfectly balanced driving of the two coils making up the quadrupole, Q is proportional to the driving current, so its sign can be flipped simply by flipping the direction of the drive current. Figure 1: Schematic of the cold-atom buoy concept. In the quadrupole configuration, the magnetic field grows linearly in the three Cartesian directions with the distance from the center (with opposite sign and doubled gradient in the vertical direction). This makes that an external homogeneous field shifts the center of the quadrupole (the \mathbf{B}=0 point – denoted with orange) with the same distance, but opposite directions from the true geometrical center (denoted with red) under a

Read the complete text