Read Mechanical and electrical properties of a nano-gap or how to play the nano-accordion Journal: a journal by Simon Hettler, Raul Arenal (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-08727.txt.

Introduction

Simon Hettler and Raul Arenal report a strange device that formed by accident inside an electron microscope experiment. While studying how crystal orientation affects electrical behavior in a layered compound, a nanometer gap opened at a grain boundary, and the gap turned the device into a controllable mechanical hinge.

Heating currents bend the device differentially, opening and closing the gap like a tiny accordion, and the electrical properties respond strongly. A large intrinsic voltage appears across the gap, shifting with the vacuum conditions and with the history of currents applied. The authors attribute most of this to molecules adsorbed on the interior surfaces. The lesson reaches beyond this device: inner surfaces can dominate electrical behavior even under high vacuum.

Catalog record

CREATORSimon Hettler, Raul Arenal
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE40 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2511-08727

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Mechanical and electrical properties of a nano-gap or how to play the nano-accordion Journal: a journal Simon Hettler, Raul Arenal Abstract In-situ transmission electron microscopy (TEM) has become an important technique to study dynamic processes at highest spatial resolution and one branch is the investigation of phenomena related with electrical currents. Here, we present experimental results obtained from a peculiar in-situ TEM device, which was prepared with the aim to analyze the relationship between (thermo)electric properties and specific crystal orientations of a misfit layered compound. The formation of a nano-sized gap at a grain boundary facilitated a precisely controllable mechanical bending of the device by application of differential heating currents. The devices’ electrical properties were found to be substantially influenced by the gap, leading to a high intrinsic voltage. This voltage additionally depends on the vacuum environment and on the history of applied heating currents. These findings are largely attributed to the presence of adsorbed molecules within the gap region. The electrical in-situ TEM studies of this work illustrate that interior surfaces can strongly influence electrical properties even under high vacuum conditions. 1 Introduction Electrical conduction in matter is mainly governed by the materials’ band structure and electron scattering processes in the material. In pristine single-crystalline bulk specimens and at finite temperatures and bias, electron-phonon interaction is the limiting factor for the conductivity. In real samples, scattering from defects in the material constitutes an additional contribution. The microstructure, including interfaces, surfaces, grain boundaries and point defects, can therefore significantly alter the electrical conductivity of real materials in comparison to defect-free single crystals. The relationship between microstructure and electrical conductivity has been subject of investigation for a long time 15 , 1 and research is continuing until today, with the motivation to improve the conductivity of electrical interconnects or the performance of thermoelectric materials 6 , 17 , 4 , 5 . Due to the continuing miniaturization of electronic devices, microscopic approaches to analyze the impact of individual defects on the electrical conductivities have been followed in the past decades 7 , 3 . Specifically, in-situ TEM has received interest due to its high spatial resolution 2 , 11 , 13 , 12 . Only recently, the possibility of performing in-situ TEM thermoelectric characterizations has been demonstrated 9 . Several Misfit-layered compound (MLC) families are promising materials for thermoelectric applications 18 . In bulk MLC materials, both grain boundaries and pore density are expected to have a strong impact on their performance. This work is part of an experiment series, where different in-situ TEM specimens of a strontium-doped variant of the calcium cobaltite (CCO) MLC family (Ca 2.93 Sr 0.07 Co 4 O 9 ) 20 have been prepared with the aim of elucidating the impact of grain boundaries and crystallographic directions on the (thermo)electric properties. Here, we present experimental results obtained from one peculiar in-situ TEM device of this series, which exhibited a nano-sized gap and will be named nano-accordion throughout the manuscript. The name is motivated by the controlled mechanical movement of the device induced by an applied differential heating current, which resembles the folding and unfolding of an accordions’ bellows. The gap also has a strong impact on the electrical characteristics, manifesting itself as a large intrinsic voltage offset, which is attributed to adsorbed molecules present in the gap region. 2 Materials and Methods 2.1 In-situ TEM In-situ transmission electron microscopy (TEM) investigations were carried out using two aberration-corrected (one probe-, the other image-corrected) Titan microscopes (Thermo Fisher Scientific) operated at 300 keV. Both microscopes were used for bright-field (BF) and dark-field (DF)-TEM imaging as well as for selected-area electron diffraction (SAED). High-angle annular dark field (HAADF) scanning (S)TEM was performed in the probe-corrected microscope and high-resolution (HR)TEM imaging was performed in the image-corrected microscope. SAED patterns were simulated using the ReciPro software 19 . A DENSolutions Wildifre specimen holder with a custom chip designed for in-situ thermoelectrical characterizations 9 was used to conduct the in-situ TEM experiments. Fabrication of the chip is described elsewhere 9 . The chip contains a silicon nitride membrane with a thickness of 1 \upmu m in its center, on which two contact pads and a differential heating element have been structured by lithography. A scanning electron microscopy (SEM) image of the membrane area of the chip is shown in Figure 1 a. The application of a heating current to the differential heating element results in the generation of a temperature gradient along a specimen that is placed between the two contact pads. A long hole of more than 50 \upmu m length is milled in the silicon nitride membrane between the two pads, which acts as thermal insulation barrier and thus ensures the generation of a large temperature gradient 9 . The hole is (partially) seen in the SEM images of the final device shown in Figures 1 c and d. Figure 1: Preparation of the nano-accordion. (a) SEM image of the membrane area with the differential heating element and the contact pads of the in-situ chip, see (d) for a zoomed-in view of the pads. (b) SEM image of the CCO material reveals its sheet-like structure, the predominant c axis direction of the material has been indicated. A sketch of the MLC structure with Co (dark blue), Ca/Sr (light blue/green) and O (red) atoms has been added. The deposited Pt, highlighted in yellow, indicates the place from where the lamella was taken and its orientation with respect to the CCO sheets. Stage tilt is 52°. (c) SEM image of the thinned device on the in-situ chip with an incident angle of the electron beam of 5°with respect to the surface of the chip. The two Pt contact pads, the thick and thin parts of the lamella as well as the long hole in the membrane are visible. The inset shows the bridge-shaped form of the lamella after transfer to a Cu TEM grid. (d) Top view of the final in-situ device. Scale bars are (a) 200 \upmu m, (b) 10 \upmu m, (c) 2 \upmu m, width of inset SEM image is 15 \upmu m and (d) 5 \upmu m. 2.2 Specimen preparation The in-situ TEM specimen was prepared using a Helios 650 dual-beam instrument (Thermo Fisher Scientific) combining SEM with a Ga + focused ion beam (FIB). In a first step, a conventional TEM lamella was prepared from a strontium-doped calcium cobaltite (CCO: Ca 2.93 Sr 0.07 Co 4 O 9 ) misfit-layered compound (MLC). The preparation of the bulk CCO material is described elsewhere 20 . The CCO material consists of the two subsystems CoO 2 and Ca 2-x Sr x CoO 3 , which are stacked alternately along the c axis of the incommensurate crystal structure, which is sketched in the inset of Figure 1 b. Figure 1 b also shows an SEM image of the CCO material, which exhibits numerous sheets in vertical direction of the image. The out-of-plane direction of the sheets (horizontal in the image) roughly corresponds to the c axis of the CCO material. The TEM lamella was prepared with the c axis of the CCO material coinciding with the long axis of the lamella, which is seen from the deposited stripe of Pt

Read the complete text