System Analysis for a high-precision high-accuracy Astrometric instrument for HWO

Jérôme Amiaux, 1 Fabien Malbet, 2 Florence Ardellier-Desages, 1 Eric Doumayrou, 1 Pierre-Antoine Frugier, 1 Renaud Goullioud, 4 Thomas Greene, 5 Lucas Labadie, 6 Pierre-Olivier Lagage, 1 Manon Lizzana, 3,10 Alain Leger, 7 Thierry Lepine, 8 Gary Mamon, 9 Jérôme Martignac, 1 Julien Michelot, 10 Fabric · 2025

Read System Analysis for a high-precision high-accuracy Astrometric instrument for HWO by Jérôme Amiaux, 1 Fabien Malbet, 2 Florence Ardellier-Desages, 1 Eric Doumayrou, 1 Pierre-Antoine Frugier, 1 Renaud Goullioud, 4 Thomas Greene, 5 Lucas Labadie, 6 Pierre-Olivier Lagage, 1 Manon Lizzana, 3,10 Alain Leger, 7 Thierry Lepine, 8 Gary Mamon, 9 Jérôme Martignac, 1 Julien Michelot, 10 Fabric (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-07113.txt.

Introduction

Jérôme Amiaux and twenty-two co-authors lay out the system design for a precision astrometry instrument aboard the Habitable Worlds Observatory, a future space telescope. The instrument's job is differential astrometry accurate to below a micro-arcsecond per measurement, precise enough to weigh Earth-like planets around the nearest Sun-like stars by watching their hosts wobble. The study integrates mission profile, instrument design, and a detailed error budget.

Major error contributors include estimating star photo-centers for targets and calibration stars, calibrating the focal plane from pixel data, and correcting telescope distortion on the sky. Reaching the end-of-mission goal takes about one hundred observations per target spread over the mission. The proposed design uses a gigapixel focal plane assembled from many CMOS chips, and the authors chart a path to technology readiness level five by 2029.

Catalog record

CREATORJérôme Amiaux, 1 Fabien Malbet, 2 Florence Ardellier-Desages, 1 Eric Doumayrou, 1 Pierre-Antoine Frugier, 1 Renaud Goullioud, 4 Thomas Greene, 5 Lucas Labadie, 6 Pierre-Olivier Lagage, 1 Manon Lizzana, 3,10 Alain Leger, 7 Thierry Lepine, 8 Gary Mamon, 9 Jérôme Martignac, 1 Julien Michelot, 10 Fabric
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE29 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2511-07113

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

System Analysis for a high-precision high-accuracy Astrometric instrument for HWO Jérôme Amiaux, 1 Fabien Malbet, 2 Florence Ardellier-Desages, 1 Eric Doumayrou, 1 Pierre-Antoine Frugier, 1 Renaud Goullioud, 4 Thomas Greene, 5 Lucas Labadie, 6 Pierre-Olivier Lagage, 1 Manon Lizzana, 3,10 Alain Leger, 7 Thierry Lepine, 8 Gary Mamon, 9 Jérôme Martignac, 1 Julien Michelot, 10 Fabrice Pancher, 2 Thibault Pichon, 1 Aki Roberge, 11 Samuel Ronayette, 1 Hugo Rousset, 2 Breann Sitarski, 11 Alessandro Sozzetti, 12 Thierry Tourette 1 Abstract This study presents a comprehensive system analysis for an instrument onboard the Habitable Worlds Observatory (HWO), designed for high-precision, high-accuracy differential astrometry, with the primary scientific goal to determine the mass of Earth-like planets around the nearest Sun-like stars. The analysis integrates the definition of the mission profile, the instrumental concept architecture, and an error budget that breaks down the key contributors to the sub-µas precision required for a single measurement. A portion of this budget addresses photo-center estimation for both the target and calibration stars used in differential astrometry. Other major contributors are related to instrumental control of systematics in the reconstruction of differential angle measurements from pixel data (focal plane calibration) to on sky line of sight (telescope distortion calibration). End-of-mission astrometry requires multiple observations (typically 100) of the same target distributed over the mission lifetime. We assess the mission profile to estimate the fraction of survey time required for astrometric survey to achieve the science objective. The proposed architecture of the instrument concept is derived from error budget and mission constraints based on a large visible detector array composed of an assembly of multiple CMOS sensor chips resulting in an overall gigapixel focal plane. We evaluate the Technology Readiness Level (TRL) and propose a way forward reaching TRL 5 level for key technologies by the Mission Consolidation Review in 2029. 1 Introduction Astrometry plays a key role in the characterization of potentially habitable planets of Earth-like size orbiting around nearby solar type stars. It is a complementary tool to the coronagraphy instrument as well as to radial velocity measurements, for performing astrophysical characterization in the next generation of space missions. While radial velocity is highly effective, it is an order of magnitude more sensitive to stellar activity than astrometry. Astrometry, therefore, plays a crucial role in determining the true mass and three-dimensional orbital parameters of telluric exoplanets around the nearest Sun-like stars. True mass is a key prerequisite for interpreting molecular detections in exoplanets atmospheres and is required to retrieve in an unambiguous manner the composition of the atmosphere (biosignatures) in the spectrum of the reflected light from the candidates’ habitable worlds. The instrument proposed is based on relative astrometric measurements, where the different targets with Earth-like candidates are observed repeatedly over the duration of the full missions. The data collected are composed of relative angular measurements between the target pointed at the center of the instrument and the reference calibration stars within the field of view. Relative astrometric signal of a star with perturbation from an orbiting exoplanet (in µas) is given by ( 9 ) : S_{\mathrm{astrom}}=3\times\left(\frac{M_{p}}{M_{\oplus}}\right)\left(\frac{a_{p}}{1~\mathrm{AU}}\right)\left(\frac{M_{\star}}{M_{\odot}}\right)^{-1}\left(\frac{D}{1~\mathrm{pc}}\right)^{-1} (1) For the definition of the instrument, we will select the sizing case of a 1 Earth mass planet M_{p} orbiting a M_{\odot} star on 1 Astronomical Unit radius orbit ( a_{p} ) located at D=10 pc from the observer. In that case the astrometric signal is 0.3 µas. The input data to astrometric signal retrieval is the variation of relative position of the target (star + exoplanet) photocenter in the relative reference frame defined by the calibration stars. The concept of operation relies on multiple sequence of observation spanning several orbiting periods of exoplanets. Each single observation consists of one pointing of the telescope to a target and staring for a duration of <1~\mathrm{hour} . Some additional calibrations are taken for each sequence to complete the data set. The input data to astrometric signal retrieval is the variation of relative position of the target (star + exoplanet) photocenter in the relative reference frame defined by the calibration stars. The concept of operation relies on multiple sequence of observation spanning several orbiting periods of exoplanets. Each single observation consists of one pointing of the telescope to a target and staring for a duration of <1 hour. Some additional calibrations are taken for each sequence to complete the data set. The typical number of revisits assumed for the mission definition is N_{\mathrm{obs}} =100 revisits per target. The distribution of the target sequence of observation will depend on the pointing capability of the observatory accounting for limitation of impacts of Solar Aspect Angle variation on thermal stability and straylight. The end of mission Signal to Noise ratio of the astrometric signal: \mathrm{SNR}_{\mathrm{astrom}}=\sqrt{N_{\mathrm{obs}}}\times\frac{S_{\mathrm{astrom}}}{\sigma_{\mathrm{1\,meas}}} (2) is set to a minimum of 6 ( 8 ) leading to a single measurement error requirement \sigma_{\mathrm{1\,meas}}=0.50~\mu\mathrm{as} . This is the error for which we will size the astrometric instrument. 2 Budget error 2.1 Budget allocation Starting from the single differential error budget of 0,5 µas the allocation is broken down to the following main contributors: a) Error of photocenter determination of target and calibration stars b) Error of pixel position to on-sky line of sight calibration c) Astronomical errors The following budget allocation is proposed (Fig. 1) and justified in following sections 2.3 and 2.4 by bottom-up verification of performance (astronomical errors are not discussed in this paper): Figure 1: Main budget allocation for high-accuracy high-precision Astrometry. All of these contributors are at the sub-micro arcsec levels making the end of mission performance mainly a calibration experiment to control the systematics below the statistical errors floor. 2.2 Assumption for design analysis The telescope will be assumed to be the one defined in Engineering Architecture Concepts EAC3 configuration with a diameter of 7,2 m and a pupil composed of 19 hexagons with a collecting area of 32,8 m² (effective diameter 6,5 m). The optical performance of the system will be characterized at first order by the FWHM of the PSF \mathrm{FWHM}_{\mathrm{PSF}}=1.03\times\lambda/D_{\mathrm{tel}}=20~\mathrm{mas} in the visible waveband (mean wavelength = 680 nm) under assumption that the system is close to diffraction limit as is expected for a high-performance coronagraph mission. The design analysis is based on 10 defining a list of preliminary representative sample of the targets that need to be addressed by the HWO mission. This list gives a sizing scenario for the observation sequence. For the photometry of target stars, based on the sample from the preliminary target list, we assume magnitude ranging from 3 to 7 with a reference Spectral Energy Distribution corresponding to a G5V star T_{\mathrm{eff}}=5660~\mathrm{K} and R_{\star}=0.997\times R_{\odot} . 2.3 Photon noise on photocenter determination The fundamental limit for astrometry accuracy is related to centroid measurement of image of stars in the pixelized focal plane. Best method to determine a stable photocenter associated to the image of the stars is still under study but for all methods, the ultimate accuracy is inversely proportional to the SNR of star cumulated flux limited by photon noise ( 4 ) . For the target star, the contribution to the final astrometric error is given by: \sigma_{\mathrm{ast,target}}=\frac{\mathrm{FWHM}_{\mathrm{PSF}}}{2\times\mathrm{SNR}_{\mathrm{target}}} (3) with \mathrm{SNR}_{\mathrm{target}}=\frac{N_{\mathrm{target\,photo\text{-}e^{-}}}}{\sqrt{N_{\mathrm{target\,photo\text{-}e^{-}}}}} (4) For the calibration stars, assuming that the relative astrometric measurement is based on N_{\mathrm{cal_{s}tar}} pairs