Task-Adaptive Low-Dose CT Reconstruction

Necati Sefercioglu 1 , Mehmet Ozan Unal 2 , Metin Ertas, Isa Yildirim 2 1 Department of Data Science and Analytics, Istanbul Technical University, Istanbul, Turkiye ([email protected]) 2 Department of Electronics and Communication Engineering, Istanbul Technical University, Istanbul, Turkiye · 2025

Read Task-Adaptive Low-Dose CT Reconstruction by Necati Sefercioglu 1 , Mehmet Ozan Unal 2 , Metin Ertas, Isa Yildirim 2 1 Department of Data Science and Analytics, Istanbul Technical University, Istanbul, Turkiye ([email protected]) 2 Department of Electronics and Communication Engineering, Istanbul Technical University, Istanbul, Turkiye (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-07094.txt.

Introduction

Necati Sefercioglu, Mehmet Ozan Unal, Metin Ertas, and Isa Yildirim make low-dose CT reconstruction serve the diagnosis, not just the image metrics. Deep learning reconstructions already score well on signal-to-noise and structural similarity, yet they often erase the fine anatomical detail clinicians need, which limits real clinical use. Their system adds a frozen, pre-trained task network as a regularizer inside the reconstruction loss, guiding training without letting the task model pull the images astray.

The test task is segmentation of the liver and its tumors. Task-adaptive models reached Dice scores up to 0.707, approaching full-dose scans at 0.874 and far ahead of joint training at 0.331 and standard reconstruction at 0.626. Because the change is only to the loss function, the system can be added to current reconstruction models.

Catalog record

CREATORNecati Sefercioglu 1 , Mehmet Ozan Unal 2 , Metin Ertas, Isa Yildirim 2 1 Department of Data Science and Analytics, Istanbul Technical University, Istanbul, Turkiye ([email protected]) 2 Department of Electronics and Communication Engineering, Istanbul Technical University, Istanbul, Turkiye
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE39 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2511-07094

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Task-Adaptive Low-Dose CT Reconstruction Necati Sefercioglu 1 , Mehmet Ozan Unal 2 , Metin Ertas, Isa Yildirim 2 1 Department of Data Science and Analytics, Istanbul Technical University, Istanbul, Turkiye ([email protected]) 2 Department of Electronics and Communication Engineering, Istanbul Technical University, Istanbul, Turkiye ([email protected], [email protected]) Abstract Deep learning-based low-dose computed tomography reconstruction methods already achieve high performance on standard image quality metrics like peak signal-to-noise ratio and structural similarity index measure. Yet, they frequently fail to preserve the critical anatomical details needed for diagnostic tasks. This fundamental limitation hinders their clinical applicability despite their high metric scores. We propose a novel task-adaptive reconstruction framework that addresses this gap by incorporating a frozen pre-trained task network as a regularization term in the reconstruction loss function. Unlike existing joint-training approaches that simultaneously optimize both reconstruction and task networks, and risk diverging from satisfactory reconstructions, our method leverages a pre-trained task model to guide reconstruction training while still maintaining diagnostic quality. We validate our framework on a liver and liver tumor segmentation task. Our task-adaptive models achieve Dice scores up to 0.707, approaching the performance of full-dose scans (0.874), and substantially outperforming joint-training approaches (0.331) and traditional reconstruction methods (0.626). Critically, our framework can be integrated into any existing deep learning-based reconstruction model through simple loss function modification, enabling widespread adoption for task-adaptive optimization in clinical practice. Our codes are available at: https://github.com/itu-biai/task_adaptive_ct † † footnotetext: Computing resources used in this work were provided by the National Center for High Performance Computing of Turkey (UHeM) under grant number 4022252025. Keywords: Computed tomography (CT), image reconstruction, low-dose CT, medical image segmentation, task-adaptive reconstruction. 1 Introduction Low-dose computed tomography (LDCT) has emerged as a critical advancement in medical imaging, offering significant reduction in radiation exposure while maintaining diagnostic capabilities. Medical studies provide strong clinical evidence that LDCT screening leads to significant mortality reduction for some cancer types [ 7 ] . For instance, lung cancer screening in high-risk populations shows that early detection via LDCT reduces lung cancer mortality by about 20-24% compared to chest X-rays or no screening [ 22 ] . Due to its implications for public health, there exists a strong motivation for LDCT, and ALARA principle has become the widespread standard for radiation exposure in medical imaging, standing for “as low as reasonably achievable” [ 15 ] . There exist two main strategies to obtain low-dose scans. Radiation exposure can be reduced both by decreasing the scanning angles to acquire fewer projections, called sparse-view CT, and by reducing X-ray tube current intensity, called dose reduction [ 38 ] . Regardless of the approach, dose reduction introduces artifacts and noise into the reconstructions, decreasing the diagnostic capabilities of the obtained scans [ 17 ] . Accordingly, low-dose reconstruction methods have emerged to mitigate these effects. Initial successful work on LDCT reconstruction relied on conventional signal processing methods and iterative methods [ 33 ] , [ 13 ] , [ 5 ] , [ 35 ] , [ 14 ] , [ 31 ] , [ 11 ] . When deep learning-based methods proved their success in classic image processing problems, the focus on LDCT research also shifted to deep learning-based reconstructions, which provided state-of-the-art results [ 18 ] , [ 10 ] , [ 39 ] , [ 16 ] , [ 3 ] , [ 2 ] , [ 20 ] . Most commonly used metrics in low-dose reconstruction literature are peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM). PSNR metric measures the ratio between the maximum possible signal power and the power of corrupting noise that affects the quality of the image. It is purely based on pixel-by-pixel differences and doesn’t consider structural information. However, SSIM calculates the structural similarity between two images by comparing local patterns of pixel intensities, considering luminance, contrast, and structure [ 37 ] , [ 12 ] . Deep learning-based reconstructions usually outperform traditional methods in both metrics, while also providing higher quality visuals with decreased noise and sharper details. Yet, it doesn’t necessarily mean that these deep learning powered reconstructions perform well in clinical practice. PSNR is highly sensitive to pixel-wise differences and doesn’t reflect the diagnostic quality, and SSIM focuses on structural similarity but may still miss subtle pathological changes. Accordingly, small lesions or pathological changes might be smoothed out while maintaining high PSNR and high SSIM, edge preservation of critical anatomical structures may be compromised despite good metric scores, and texture changes that are clinically significant might be altered while keeping the metrics high [ 27 ] , [ 21 ] , [ 9 ] , [ 23 ] . Radiologists might perform various tasks after low-dose reconstruction. They can conduct detection tasks like tumor detection and lesion detection, segmentation tasks like organ segmentation and tumor segmentation, and classification tasks like tumor classification, among various other tasks [ 4 ] . Currently, deep learning-based methods can also conduct these tasks with notable performances when fed full-dose scans as inputs [ 32 ] , [ 19 ] , [ 34 ] . Surprisingly, there remains a great gap in the literature about performances of LDCT reconstructions in the aforementioned tasks. Most of the previous work on LDCT reconstruction literature focus on increasing performance in PSNR and SSIM metrics, and abandon any further assessment and modification. However, as described above, these metrics are not sufficient to conclude that obtained reconstructions maintain enough information to conduct diagnostic tasks from. We acknowledge that PSNR and SSIM metrics are useful for evaluating low-dose reconstruction models, but emphasize that they are not sufficient to assess the potential clinical applicability of the models. In this work we won’t present a new metric, but we advise the audience to research the recent literature about medical image quality assessment [ 27 ] , [ 21 ] , [ 9 ] , [ 23 ] . This research focuses on enhancing the clinical interpretability of the low-dose scans during the reconstruction process. In other words, we focus on creating reconstructions with enhanced performances in diagnostic tasks, what is usually called task-adapted, task-oriented, or task-informed reconstruction in the literature [ 1 ] , [ 40 ] , [ 36 ] , [ 25 ] , [ 26 ] . To the best of our knowledge, Adler et al. [ 1 ] proposed the foundational work in task-adapted reconstruction literature, applying a joint-training framework that trains both reconstruction and task networks simultaneously with a corresponding hyperparameter controlling the weight between reconstruction and task losses. Valat et al. [ 36 ] and Li et al. [ 25 ] , [ 26 ] employ this joint-training approach and provide further evidence that joint-training framework is working as intended using systematic evaluations. Zhang et al. [ 40 ] propose a novel approach where they introduce a task-oriented loss in the WGAN [ 6 ] . They add a task-oriented loss, coming from a frozen pre-trained task network and a reconstruction loss, into the discriminator loss of the WGAN. Weight hyperparameter is only present for the reconstruction loss, a tradeoff doesn’t exist between reconstruction loss and task loss like the joint-training approach. Joint training approach of Adler et al. [ 1 ] provides significant results about

Read the complete text