TRAECR: A Tool for Preprocessing Positron Emission Tomography Imaging for Statistical Modeling

Akhil Ambekar, Robert Zielinski, Ani Eloyan · 2025

Read TRAECR: A Tool for Preprocessing Positron Emission Tomography Imaging for Statistical Modeling by Akhil Ambekar, Robert Zielinski, Ani Eloyan (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-04458.txt.

Introduction

Akhil Ambekar and two colleagues built TRAECR, a tool that prepares PET brain scans for statistics. PET imaging helps study cancer and Alzheimer's disease, including whether new drugs cut amyloid. Raw scans, though, need careful preprocessing before any model can use them.

TRAECR handles that preparation and adds views that help users check each step. The authors explain the background statisticians need when they first meet PET data. Good preprocessing matters because later claims, like links between amyloid loss and thinking scores, rest on it. The tool aims to make those pipelines clearer and easier to repeat.

Catalog record

CREATORAkhil Ambekar, Robert Zielinski, Ani Eloyan
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE42 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2511-04458

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

TRAECR: A Tool for Preprocessing Positron Emission Tomography Imaging for Statistical Modeling Akhil Ambekar, Robert Zielinski, Ani Eloyan Abstract Positron emission tomography (PET) imaging is widely used in a number of clinical applications, including cancer and Alzheimer’s disease (AD) diagnosis, monitoring of disease development, and treatment effect evaluation. Statistical modeling of PET imaging is essential to address continually emerging scientific questions in these research fields, including hypotheses related to evaluation of effects of disease modifying treatments on amyloid reduction in AD and associations between amyloid reduction and cognitive function, among many others. In this paper, we provide background information and tools for statisticians interested in developing statistical models for PET imaging to pre-process and prepare data for analysis. We introduce our novel pre-processing and visualization tool TRAECR (Template registration, MRI-PET co-Registration, Anatomical brain Extraction and COMBAT/RAVEL harmonization) to facilitate data preparation for statistical analysis. Keywords: Pre-processing pipeline; Quality control; User friendly workflow 1 Introduction Brain imaging technologies, such as Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET), include important tools widely used in modern medical research for clinical diagnosis of neurodegerative diseases and monitoring of disease progression. These modalities provide detailed visualizations of the brain’s anatomical structures, evaluation of functional activity in the brain, and crucial information on glucose metabolism in specific brain regions. These findings are essential for understanding neurological disorders, guiding surgical procedures, and monitoring response to therapeutic interventions. The precision and reliability of the images collected by these technologies as well as the modeling pipelines implemented to analyze the data are critical, as they directly influence diagnostic decisions and subsequent medical or research outcomes ( 29 ) . ( 12 ) provide a thorough overview of the history of innovations that lead to the introduction of PET imaging and developments of this technology since its inception. Pre-processing pipelines are an important step for preparation of images for statistical modeling. When modeling imaging data to address population level hypotheses, statisticians often work with imaging data from large, multicenter studies, i.e. where data is collected in different sites. Pre-processing brain imaging data from modalities like MRI and PET presents various challenges that can impact data quality and utility. Key sources of systematic noise impacting image quality in most multi-center imaging studies include differences in scanner hardware (e.g. manufacturer, magnetic field strength), software protocols (e.g. pulse sequences, reconstruction algorithms), and image acquisition parameters (e.g. voxel size, echo time, repetition time) ( 11 ) . These variations can lead to significant discrepancies in image quality and characteristics both between and within data collection sites. This variability between scanners complicates comparisons between study populations and can introduce biases in multicenter research ( 31 ) . In addition, MRI and PET scans are prone to various artifacts, including motion-blur, susceptibility distortions, and noise arising from patient movement or physiological processes. These artifacts can obscure critical details and introduce bias in image analyses results ( 33 ) . Accurate alignment and registration of brain images whether within participant or to a common template space are essential in multi-modal studies or longitudinal monitoring, requiring sophisticated computational techniques to ensure a precise overlay of anatomical and functional data ( 6 ) . Due to these pre-processing challenges, solutions that can standardize, enhance, and harmonize images before performing analysis are essential. Since “concurrent” MRI scans are often used for pre-processing of PET images, we discuss MRI and PET pre-processing together henceforth. The R programming language ( 25 ) is increasingly used for modeling MRI and fMRI data with the introduction of various packages for processing and modeling imaging data available in public software repositories, including CRAN and neuroconductor ( 17 ) . Existing pre-processing software suites in R include the FMRIB Software Library (FSL) ( 30 ) , Statistical Parametric Mapping (SPM) ( 23 ) , and Advanced Normalization Tools (ANTs) ( 1 ) , which offer pre-processing functionalities such as skull stripping, motion correction, artifact reduction, and image registration. However, these solutions often require extensive tuning and coding expertise, as well as familiarity with the individual packages used in the pre-processing steps. Integrating multiple pre-processing steps across different software packages can introduce complexity and potential errors in data handling, increasing the burden on researchers and clinicians. In addition, pre-processing PET data, while often including steps similar to those used for pre-processing other data modalities (e.g. registration to a common template space, skull stripping), has specific differences. Hence, it is important to consider the adaptation of pre-processing pipelines when modeling PET images. These factors make it difficult for researchers to comprehensively address all needs within a unified workflow. These limitations may result in barriers for researchers new to the field of PET imaging analysis. To mitigate these challenges, we developed TRAECR, an integrated PET pre-processing tool designed with a user-friendly interface and comprehensive functionality, implemented as an R Shiny application. TRAECR also includes an artifact-detection dashboard developed in Python ( 28 ) using Plotly’s Dash framework ( 24 ) . This dashboard is designed to help detect and filter artifacts in MRI and PET scans by calculating and visualizing quantitative image quality metrics (reported as raw values and their z-scores). It provides a useful mechanism for determining which image files should be included for pre-processing or excluded from further analysis. The core features of TRAECR include brain extraction by using the fslbet_robust function from extrantsr package in R. This approach efficiently isolates brain tissue from MRI scans by removing non-brain structures, including the scalp, skull, and neck, which helps produce brain-only images. The tool also performs registration of the brain-extracted images to the Montreal Neurological Institute (MNI) template space ( 15 ) using the FMRIB’s Linear Image Registration Tool (FLIRT) algorithm, facilitating standardized comparisons across participants and studies. Additionally, the MRI-PET co-registration functionality of TRAECR aligns PET images with corresponding MRI scans to enable precise overlay of functional data onto anatomical structures, enhancing multi-modal analyses. To adjust for batch effects and scanner-induced variability, the tool implements the COMBAT harmonization method ( 8 ) that improves data comparability between different scanners or study sites. Finally, TRAECR utilizes the RAVEL normalization algorithm ( 9 ) to reduce variability arising from non-biological factors, such as scanner-related differences, ensuring that true biological signals are preserved in the data. By integrating these functionalities into a single, user-friendly platform, TRAECR simplifies the pre-processing workflow while improving the consistency and comparability of brain imaging data across different studies and scanners. It offers researchers and clinicians a streamlined approach to handle essential pre-processing, enhancing efficiency, reducing errors, and saving valuable time and effort in neuroimaging research. This paper serves as both a tutorial and an introduction to a useful tool for pre-processing for statisticians new to modeling PET imaging data. 2 Background PET has become a crucial imaging technique in modern medicine, providing deep insight into the physiological and molecular functions of the human body. By using radiotracers tagged with positron-emitting isotopes, PET enables minimally invasive visualization and measurement of biochemical processes in living organism ( in vivo ) ( 14 ) . This powerful capability is important for the early detection of diseases such as Alzheimer’s disease (AD), tracking how patients respond to treatments, and enhancing understanding of various pathological conditions. In this

Read the complete text