Quantum Optical Techniques for Biomedical Imaging
Vahid Salari, Yingwen Zhang, Sepideh Ahmadi, Dilip Paneru, Duncan England, Shabir Barzanjeh, Robert Boyd, Ebrahim Karimi, Christoph Simon, Daniel Oblak · 2025
Read Quantum Optical Techniques for Biomedical Imaging by Vahid Salari, Yingwen Zhang, Sepideh Ahmadi, Dilip Paneru, Duncan England, Shabir Barzanjeh, Robert Boyd, Ebrahim Karimi, Christoph Simon, Daniel Oblak (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-03935.txt.
Introduction
Vahid Salari is the lead author among ten authors reviewing quantum optical methods for biomedical imaging. Techniques that use entanglement, squeezing, and quantum correlations aim to beat classical limits, promising sharper resolution, better signal relative to noise, stronger phase sensitivity, and lower radiation dose for delicate samples.
Coverage includes quantum optical coherence tomography, quantum microscopy, ghost imaging, multi-parameter quantum imaging, and imaging with quantum-grade cameras. For each method the review explains how it works, where it could help in biomedicine, and what blocks translation into real practice. The survey is meant as a guide for moving quantum imaging from laboratory demonstrations toward tools that affect care.
Catalog record
| CREATOR | Vahid Salari, Yingwen Zhang, Sepideh Ahmadi, Dilip Paneru, Duncan England, Shabir Barzanjeh, Robert Boyd, Ebrahim Karimi, Christoph Simon, Daniel Oblak |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 58 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2511-03935
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Quantum Optical Techniques for Biomedical Imaging Vahid Salari, Yingwen Zhang, Sepideh Ahmadi, Dilip Paneru, Duncan England, Shabir Barzanjeh, Robert Boyd, Ebrahim Karimi, Christoph Simon, Daniel Oblak Abstract Quantum imaging is emerging as a transformative approach for biomedical applications, applying nonclassical properties of light, such as entanglement, squeezing, and quantum correlations, to overcome fundamental limits of conventional techniques. These methods promise superior spatial resolution, enhanced signal-to-noise ratios, improved phase sensitivity, and reduced radiation dose, for potentially safer and more precise imaging for delicate biological samples. Here, we present an overview of quantum optical biomedical imaging technologies as well as quantum-inspired imaging methods, including quantum optical coherence tomography, quantum optical microscopy, ghost imaging, multi-parameter quantum imaging, and imaging with quantum-grade cameras. We describe the operating principles, biomedical applications, and unique advantages of each approach, along with the specific challenges for their translation into real-life practice. This review aims to guide future research toward advancing quantum imaging from experimental demonstrations to impactful biomedical tools. I Introduction Biomedical imaging techniques are central to diagnosing and monitoring a wide range of diseases. Before the discovery of X-rays in 1895, the only reliable means of visualizing internal anatomy was invasive surgery, which carried significant trauma and risk for patients Spaner and Warnock 1997 . Today, biomedical imaging supports accurate diagnosis, therapeutic guidance, and disease monitoring across a wide range of conditions without surgery and almost non-invasively Beutel et al. 2000 ; Guy and Ffytche 2005 ; Hendee and Ritenour 2003 ; Prince and Links 2015 ; Allisy-Roberts and Williams 2007 ; Bharath 2008 ; Peter 2009 ; Smith and Webb 2010 ; Flower 2012 ; Ahmad et al. 2014 ; Lancaster and Hasegawa 2016 ; Elangovan and Jeyaseelan 2016 ; Kasban et al. 2015 ; Suetens 2017 ; Webb 2017 . In a typical imaging procedure, energy from a suitable source is directed toward the body, where it interacts with tissues through absorption, scattering, or transmission. The modified signals are then captured by detectors and processed by computational algorithms to reconstruct images. Optical imaging techniques are convenient, less expensive, and safe techniques for biomedical imaging Shi and Alfano 2017 ; Benaron et al. 2000 ; Saouli and Mansour 2011 . Fluorescent imaging Lauwerends et al. 2021 , photoacoustic imaging Attia et al. 2019 , endoscopy Natalin and Landman 2009 , diffuse optical tomography (DOT) Hoshi and Yamada 2016 ; Jiang 2018 , super-resolution microscopy Sigal et al. 2018 and optical coherence tomography (OCT) Huang et al. 1991 ; Schmitt 1999 ; Fercher et al. 2003 ; Welzel 2001 ; Fujimoto 2003 ; Serranho et al. 2012 ; Shu et al. 2017 are a few examples among others. Recently, some of these techniques have been further developed by using quantum optical techniques Mandel and Wolf 1995 ; Walls and Milburn 2008 , leading to the development of quantum imaging Boyd 2003 ; Moreau et al. 2019 ; Genovese 2016 . Quantum mechanics, developed in the first half of the twentieth century, has significantly enhanced measurement accuracy and sensitivity by exploiting non-classical features, particularly nonclassical correlations Giovannetti et al. 2011 ; Giovannetti et al. 2004 ; Caves 1981 . Quantum optical imaging is supposed to overcome the limitations of classical optical imaging, producing images with higher resolution and sensitivity by using quantum properties of light such as quantum entanglement Brida et al. 2010a ; Genovese 2016 ; Moreau et al. 2019 . These techniques promise improved performance compared to conventional imaging systems, reduced radiation exposure, and perform better in high-noise environments Brida et al. 2010a ; Tan et al. 2008 ; Lloyd 2008 . Some of these quantum imaging techniques include Interaction-Free (IF) imaging Elitzur and Vaidman 1993 ; Kwiat et al. 1995 , quantum ghost imaging (QGI) Pittman et al. 1995a ; Erkmen and Shapiro 2010a , Quantum Illumination (QI) Lloyd 2008 ; Tan et al. 2008 ; Barzanjeh et al. 2015 ; Gallego Torromé and Barzanjeh 2024 ; Barzanjeh et al. 2020 , Quantum Optical Coherence Tomography (QOCT) Abouraddy et al. 2002a ; Hong et al. 1987 , and other techniques based on quantum optical sensing methods Degen et al. 2017 ; Giovannetti et al. 2011 . Further advantages of quantum imaging are in biological measurements, such as quantum-enhanced particle tracking Yamada et al. 2000 ; Greenleaf and Block 2006 ; Kukura et al. 2009 ; Taylor et al. 2014 ; Zhang et al. 2019a , measuring biomagnetic fields Bison et al. 2003a ; Bison et al. 2003b ; Xia et al. 2006 ; Bison et al. 2009 ; Johnson et al. 2013 , refractive index sensing of protein solutions Crespi et al. 2012 , and microrheology Selhuber-Unkel et al. 2009 ; Grebenkov et al. 2013 . II Quantum light sources Quantum imaging typically employs pairs of entangled photons. In one configuration, both of these photons interact with the target before being separately measured by their respective detectors. Alternatively, the photons are separated and one photon of the pair, known as the signal photon, interacts with the object and is then collected by a detector. The idler photon, which is entangled with the signal photon, is used as a reference, and is collected by a separate detector (see Fig. 1 (a)). Typically, to obtain an image of the object, the time and position correlation between the two photons are measured. However, it is also possible to utilize the correlations in additional degrees of freedom, such as polarization, spectrum and momentum, to gain further information about the object. The advantages of quantum imaging through entanglement over classical imaging techniques are gained by analyzing the quantum correlations between the entangled photon pairs. Under certain conditions, these correlations make it possible to see details smaller than the diffraction limit Boto et al. 2000 ; Giovannetti et al. 2004 , reduce noise below the shot-noise level Xiao et al. 1987 ; Gerry and Knight 2005 , and filter out unwanted background light Pittman et al. 1995b ; Shih 2011 . The sub shot-noise and background filtering ability allow quantum imaging methods to work with fewer photons, thereby exposing the object to less radiation Morris et al. 2015 ; Lemos et al. 2014a . This makes them especially useful for studying fragile samples that could be damaged by light or that need to stay at very low temperatures, where weak illumination is a must to avoid heating. Below, we list some of the most commonly used quantum light sources and quantum states employed for quantum imaging. Spontaneous parametric down-conversion: One of the most common processes for the creation of entangled photon pairs is through the process of spontaneous parametric down-conversion (SPDC) Harris et al. 1967 ; Ghosh and Mandel 1987 . In this process, a laser (light beam) at frequency \omega_{P} is used to pump a nonlinear crystal with a large second-order nonlinearity \chi^{(2)} , such as \beta -barium borate (BBO), lithium niobate (LiNbO 3 ) or potassium titanyl phosphate (KTiOPO 4 ) crystals. In SPDC, a pump photon at frequency \omega_{p} is converted into a pair of lower-frequency photons, called signal and idler ( \omega_{s},\omega_{i} ), mediated by the second-order nonlinear polarization P^{(2)}(t)=\epsilon_{0}\chi^{(2)}E^{2}(t) where P^{(2)}(t) is the second-order nonlinear polarization, \epsilon_{0} is the vacuum permittivity, \chi^{(2)} is the second-order nonlinear