Plasma Processing of FRIB Low-Beta Cryomodules using Higher-Order-Modes
P. Tutt, W. Chang, K. Elliott, W. Hartung, S. Kim, K. Saito, T. Xu Facility for Rare Isotope Beams, Michigan State University, East Lansing, MI, USA · 2025
Read Plasma Processing of FRIB Low-Beta Cryomodules using Higher-Order-Modes by P. Tutt, W. Chang, K. Elliott, W. Hartung, S. Kim, K. Saito, T. Xu Facility for Rare Isotope Beams, Michigan State University, East Lansing, MI, USA (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-02151.txt.
Introduction
P. Tutt and six colleagues at the Facility for Rare Isotope Beams report progress on cleaning accelerator cavities with plasma while they stay installed in their modules. Plasma processing had already improved superconducting cavities at other laboratories by reducing field emission. The Michigan facility's quarter-wave and half-wave resonators pose a catch: their power couplers are deliberately weak, which badly mismatches the plasma process at room temperature.
Driving the plasma with higher-order modes instead reduces the mismatch and raises plasma density. A spare cryomodule was processed in January 2024, and the first in-tunnel trial followed in September 2025. Cold tests before and after showed some cavities reaching notably higher accelerating gradients before field emission began, and a dual-drive variant is being explored to strengthen the effect.
Catalog record
| CREATOR | P. Tutt, W. Chang, K. Elliott, W. Hartung, S. Kim, K. Saito, T. Xu Facility for Rare Isotope Beams, Michigan State University, East Lansing, MI, USA |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 24 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2511-02151
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Plasma Processing of FRIB Low-Beta Cryomodules using Higher-Order-Modes Thanks: This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics and High Energy Physics and used resources of the FRIB Operations, which is a DOE Office of Science User Facility under Award Numbers DE-SC0023633 and DE-SC0018362. Additional support was provided by the MSU/FRIB Accelerator Science and Engineering Traineeship program. P. Tutt, W. Chang, K. Elliott, W. Hartung, S. Kim, K. Saito, T. Xu Facility for Rare Isotope Beams, Michigan State University, East Lansing, MI, USA Abstract Improvement in SRF accelerator performance after in-tunnel plasma processing has been seen at SNS and CEBAF. Plasma processing development for FRIB quarter-wave and half-wave resonators (QWRs, HWRs) was initiated in 2020. Plasma processing on individual QWRs ( β = 0.085 \beta=0.085 ) and HWRs ( β = 0.53 \beta=0.53 ) has been found to significantly reduce field emission. A challenge for the FRIB cavities is the relatively weak fundamental power coupler (FPC) coupling strength (chosen for efficient continuous-wave acceleration), which produces a lot of mismatch during plasma processing at room temperature. For FRIB QWRs, driving the plasma with higher-order modes (HOMs) is beneficial to reduce the FPC mismatch and increase the plasma density. The first plasma processing trial on a spare FRIB QWR cryomodule was done in January 2024, with before-and-after bunker tests and subsequent installation into the linac tunnel. The first in-tunnel plasma processing trial was completed in September 2025. For both cryomodules, before-and-after cold tests showed a significant increase in the average accelerating gradient for field emission onset after plasma processing for some cavities. In parallel with the cryomodule trials, the use of dual-drive plasma is being explored with the goal of improving the effectiveness of plasma processing. 1 Introduction Superconducting radio frequency (SRF) cavities are a fundamental component of modern particle accelerators due to their extremely low dissipated power, enabling operation at high gradients and in continuous wave (CW) mode. SRF cavities are used in facilities around the world to accelerate electrons, protons, and ions for a variety of scientific purposes. While great care is taken with surface preparation and clean assembly to produce high-performance field emission (FE) free cavities, imperfect processes, subsequent assembly into cryomodules, and long-term accelerator operation provide opportunities for particulate contamination. As a result, FE may degrade the cavity performance. Surface treatments such as mechanical polishing, buffered chemical polishing (BCP), electropolishing (EP), and high-pressure rinsing (HPR) may remove contamination and improve the performance, but they cannot be performed in situ. For a cryomodule with degraded performance, disassembly is required to apply the aforementioned techniques. Disassembly and refurbishment of a cryomodule is time-consuming and costly. The Facility for Rare Isotope Beams (FRIB) is a user facility with 324 coaxial SRF cavities supporting nuclear physics experiments since 2022, with beam energies reaching up to 200 MeV per nucleon [ 1 ] . As beam operations at FRIB continue, future FE degradation is of concern [ 2 ] . Plasma processing is an in-situ technique to improve the performance of SRF cavities and is being investigated at FRIB. Several accelerator facilities have reported success in improving the FE onset and thereby the usable accelerating gradient via plasma processing in spare cavities, offline cryomodules, and in-linac cryomodules [ 3 , 4 , 5 , 6 , 7 , 8 ] . We have conducted successful plasma processing trials on spare FRIB cavities [ 9 , 10 ] and on one offline FRIB cryomodule [ 11 ] . The first demonstration of plasma processing in the FRIB linac tunnel is reported in this paper. A higher-order mode (HOM) was used to ignite and sustain the plasma via the fundamental power coupler (FPC). The plasma systems and procedures will be discussed, along with the cryomodule performance in before-and-after cold tests. A parallel effort is underway to study plasma processing via dual-driven HOMs [ 12 ] ; additional results from this effort will be presented. 2 Plasma Processing: Basics Plasma processing was developed to remove hydrocarbon contamination on the inner surface of SRF cavities. A mixture of inert gas (Ar, Ne, or He) and oxygen is supplied to the cavity at room temperature. RF power is used to ignite a glow discharge inside the cavity using the FPC or an HOM coupler. Disassociation of the diatomic oxygen creates oxygen radicals that can react with hydrocarbon chains on the surface, producing volatile byproducts such as H 2 O, CO 2 , and CO. Active pumping on the cavity maintains the cavity pressure and allows for byproducts to be removed during processing. Monitoring of these byproducts by a residual gas analyzer (RGA) can provide information about the removal of contaminants. To enhance the density of oxygen radicals for more efficient cleaning, the electron number density ( n_{e} ) should be increased. This can be done by increasing the forward power ( P_{f} ) or increasing the drive frequency ( f_{d} ). Higher P_{f} provides more energy to the plasma for production of more ionization. A higher f_{d} is beneficial because the resonant frequency of the cavity shifts up due to presence of the plasma and associated decrease in the effective permittivity [ 13 ] . By shifting f_{d} closer to the new resonance, more power is coupled into the cavity; however, this enhances the density and causes the resonance to shift further, as discussed in previous papers [ 10 , 6 , 5 ] . 3 Challenges and Development Efforts for FRIB Cavities The primary limitation for FRIB plasma processing is the significant mismatch of the fundamental mode when the cavity is warm, which raises concerns about breakdown within the coupler space. HOMs can be used to lessen this mismatch for FRIB QWRs [ 9 ] . Cold tests on both \beta=0.53 HWRs and \beta=0.085 QWRs before and after plasma processing showed an improvement in the field emission onset [ 9 , 10 ] . The procedures developed on QWRs were applied to a spare QWR cryomodule in January 2024 [ 11 ] . Four out of eight cavities were plasma-processed using either the TEM 5\lambda/4 mode ( \sim 400 MHz), a dipole mode ( \sim 605 MHz), or both. Before-and-after cold tests showed an increase in the FE onset field for 3 out of 4 cavities. 4 First In-Tunnel Plasma Processing Trial for the FRIB Linac Following the successful plasma processing trial with an offline QWR cryomodule, the first in-tunnel trial on a FRIB QWR cryomodule (SCM805/CB06) was done during the Summer 2025 maintenance period (August-September). The \beta=0.085 cryomodule showing the most field emission degradation was selected for this trial. The preliminary results will be presented in this section, including the impact of plasma processing on field emission performance; a more detailed analysis of the plasma measurements, the process by-products, and impact on multipacting is planned. 4.1 Plasma Processing System A gas supply and pumping cart for plasma processing of FRIB cryomodules was designed, fabricated, and used for both cryomodule trials, with some adjustments after the offline trial. Figure 1 shows a schematic of the cart and connections to the linac. Two gas streams (pure argon and an 80:20 mix of argon/oxygen) are combined upstream of